Title: Real-time selected ion flow tube mass spectrometry to assess short- and long-term variability in oral and nasal breath
Authors: SLINGERS, Gitte 
Goossens, R.
Janssens, H
Spruyt, M.
Goelen, E.
Vanden, Eede M.
RAES, Marc 
Koppen, G.
Issue Date: 2020
Publisher: IOP PUBLISHING LTD
Source: JOURNAL OF BREATH RESEARCH, 14 (3) (Art N° 036006)
Abstract: Breath-based non-invasive diagnostics have the potential to provide valuable information about a person's health status. However, they are not yet widely used in clinical practice due to multiple factors causing variability and the lack of standardized procedures. This study focuses on the comparison of oral and nasal breathing, and on the variability of volatile metabolites over the short and long term. Selected ion flow tube mass spectrometry (SIFT-MS) was used for online analysis of selected volatile metabolites in oral and nasal breath of 10 healthy individuals five times in one day (short-term) and six times spread over three weeks (long-term), resulting in nearly 100 breath samplings. Intra-class correlation coefficients (ICCs) were used to assess short- and long-term biological variability. Additionally, the composition of ambient air was analyzed at different samplings. The selected volatiles common in exhaled breath were propanol, 2,3-butanedione, acetaldehyde, acetone, ammonia, dimethyl sulfide, isoprene, pentane, and propanal. Additionally, environmental compounds benzene and styrene were analyzed as well. Volatile metabolite concentrations in ambient air were not correlated with those in exhaled breath and were significantly lower than in breath samples. All volatiles showed significant correlation between oral and nasal breath. Five were significantly higher in oral breath compared to nasal breath, while for acetone, propanal, dimethyl sulfide, and ammonia, concentrations were similar in both matrices. Variability depended on the volatile metabolite. Most physiologically relevant volatiles (acetone, isoprene, propanol, acetaldehyde) showed good to very good biological reproducibility (ICC > 0.61) mainly in oral breath and over a short-term period of one day. Both breathing routes showed relatively similar patterns; however, bigger differences were expected. Therefore, since sampling from the mouth is practically more easy, the latter might be preferred.
Notes: Koppen, G (corresponding author), Flemish Inst Technol Res, Unit Hlth, B-2400 Mol, Belgium.
gudrun.koppen@vito.be
Other: Koppen, G (corresponding author), Flemish Inst Technol Res, Unit Hlth, B-2400 Mol, Belgium. gudrun.koppen@vito.be
Keywords: real-time breath analysis;SIFT-MS;oral and nasal breathing;longitudinal follow up;breath volatiles;biological variability
Document URI: http://hdl.handle.net/1942/32612
ISSN: 1752-7155
e-ISSN: 1752-7163
DOI: 10.1088/1752-7163/ab9423
ISI #: WOS:000548340300001
Rights: © 2020 IOP Publishing Ltd
Category: A1
Type: Journal Contribution
Validations: ecoom 2021
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
slingers.pdf
  Restricted Access
Published version1.29 MBAdobe PDFView/Open    Request a copy
Show full item record

WEB OF SCIENCETM
Citations

9
checked on Apr 30, 2024

Page view(s)

22
checked on May 24, 2022

Download(s)

16
checked on May 24, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.