Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/32650
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBellezzo, Murillo-
dc.contributor.authorFonseca, Gabriel P.-
dc.contributor.authorVoncken, Robert-
dc.contributor.authorVerrijssen, An-Sofie-
dc.contributor.authorVan Beveren, Celine-
dc.contributor.authorRoelofs, Erik-
dc.contributor.authorYoriyaz, Helio-
dc.contributor.authorRENIERS, Brigitte-
dc.contributor.authorVan Limbergen, Evert J.-
dc.contributor.authorBerbee, Maaike-
dc.contributor.authorVerhaegen, Frank-
dc.date.accessioned2020-11-23T09:42:59Z-
dc.date.available2020-11-23T09:42:59Z-
dc.date.issued2020-
dc.date.submitted2020-11-03T14:21:13Z-
dc.identifier.citationBRACHYTHERAPY, 19 (4) , p. 544 -553-
dc.identifier.urihttp://hdl.handle.net/1942/32650-
dc.description.abstractPURPOSE: Dose escalation yields higher complete response to rectal tumors, which may enable the omission of surgery. Dose escalation using 50 kVp contact x-ray brachytherapy (CXB) allow the treatment of a selective volume, resulting in low toxicity and organs-at-risk preservation. However, the use of CXB devices is limited because of its high cost and lack of treatment planning tools. Hence, the MAASTRO applicator (for HDR Ir-192 sources) was developed and characterized by measurements and Monte Carlo simulations to be a cost-effective alternative to CXB devices. METHODS AND MATERIALS: A cylindrical applicator with lateral shielding was designed to be used with a rectoscope using its tip as treatment surface. Both the applicator and the rectoscope have a slanted edge to potentially allow easier placement against tumors. The applicator design was achieved by Monte Carlo modeling and validated experimentally with film dosimetry, using the Papillon 50 (P50) device as reference. RESULTS: The applicator delivers CXB doses in less than 9 min using a 20375 U source for a treatment area of approximately 20 x 20 mm(2) at 2 mm depth. Normalized at 2 mm, the dose falloff for depths of 0 mm, 5 mm, and 10 mm are 130%, 70%, and 43% for the P50 and 140%, 67%, and 38% for the MAASTRO applicator, respectively. CONCLUSIONS: The MAASTRO applicator was designed to use HDR Ir-192 sources to deliver a dose distribution similar to those of CXB devices. The applicator may provide a cost-effective solution for endoluminal boosting with clinical treatment planning system integration. (C) 2020 Published by Elsevier Inc. on behalf of American Brachytherapy Society.-
dc.description.sponsorshipM.B. was partially supported by a scholarship from CNPq, Conselho Nacional de Desenvolvimento Cientifico e Tecnologico-Brazil, grant number 200402/2015-3.-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE INC-
dc.rights2020 Elsevier Inc. except certain content provided by third parties.-
dc.subject.otherBrachytherapy-
dc.subject.otherMonte Carlo-
dc.subject.otherContact radiotherapy-
dc.subject.otherRectal applicator-
dc.titleAdvanced design, simulation, and dosimetry of a novel rectal applicator for contact brachytherapy with a conventional HDR 192Ir source-
dc.typeJournal Contribution-
dc.identifier.epage553-
dc.identifier.issue4-
dc.identifier.spage544-
dc.identifier.volume19-
local.bibliographicCitation.jcatA1-
dc.description.notesVerhaegen, F (corresponding author), Maastricht Univ, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, Med Ctr, NL-6201 BN Maastricht, Netherlands.-
dc.description.notesfrank.verhaegen@maastro.nl-
dc.description.otherVerhaegen, F (corresponding author), Maastricht Univ, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, Med Ctr, NL-6201 BN Maastricht, Netherlands. frank.verhaegen@maastro.nl-
local.publisher.placeSTE 800, 230 PARK AVE, NEW YORK, NY 10169 USA-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1016/j.brachy.2020.03.009-
dc.identifier.pmid32386884-
dc.identifier.isiWOS:000550573500019-
dc.contributor.orcidRENIERS, Brigitte/0000-0001-7084-4696; Roelofs, Erik/0000-0003-2172-8669-
local.provider.typewosris-
local.uhasselt.uhpubyes-
local.description.affiliation[Bellezzo, Murillo; Fonseca, Gabriel P.; Voncken, Robert; Verrijssen, An-Sofie; Van Beveren, Celine; Roelofs, Erik; Van Limbergen, Evert J.; Berbee, Maaike; Verhaegen, Frank] Maastricht Univ, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, Med Ctr, NL-6201 BN Maastricht, Netherlands.-
local.description.affiliation[Bellezzo, Murillo; Yoriyaz, Helio] Inst Pesquisas Energet & Nucl IPEN CNEN SP, Ctr Engn Nucl, Sao Paulo, Brazil.-
local.description.affiliation[Reniers, Brigitte] Hasselt Univ, Ctr Environm Sci, Res Grp NuTeC, Diepenbeek, Belgium.-
item.contributorBellezzo, Murillo-
item.contributorFonseca, Gabriel P.-
item.contributorVoncken, Robert-
item.contributorVerrijssen, An-Sofie-
item.contributorVan Beveren, Celine-
item.contributorRoelofs, Erik-
item.contributorYoriyaz, Helio-
item.contributorRENIERS, Brigitte-
item.contributorVan Limbergen, Evert J.-
item.contributorBerbee, Maaike-
item.contributorVerhaegen, Frank-
item.fullcitationBellezzo, Murillo; Fonseca, Gabriel P.; Voncken, Robert; Verrijssen, An-Sofie; Van Beveren, Celine; Roelofs, Erik; Yoriyaz, Helio; RENIERS, Brigitte; Van Limbergen, Evert J.; Berbee, Maaike & Verhaegen, Frank (2020) Advanced design, simulation, and dosimetry of a novel rectal applicator for contact brachytherapy with a conventional HDR 192Ir source. In: BRACHYTHERAPY, 19 (4) , p. 544 -553.-
item.accessRightsClosed Access-
item.fulltextNo Fulltext-
item.validationecoom 2021-
crisitem.journal.issn1538-4721-
crisitem.journal.eissn1873-1449-
Appears in Collections:Research publications
Show simple item record

WEB OF SCIENCETM
Citations

3
checked on Apr 30, 2024

Page view(s)

34
checked on Apr 26, 2023

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.