Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/33050
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMOUMDJIAN, Lousin-
dc.contributor.authorVervust, Thomas-
dc.contributor.authorSix, Joren-
dc.contributor.authorSchepers, Ivan-
dc.contributor.authorLesaffre, Micheline-
dc.contributor.authorFEYS, Peter-
dc.contributor.authorLeman, Marc-
dc.date.accessioned2021-01-06T12:33:43Z-
dc.date.available2021-01-06T12:33:43Z-
dc.date.issued2021-
dc.date.submitted2021-01-05T14:07:41Z-
dc.identifier.citationJournal on Multimodal User Interfaces (Printed), 15 (1), p. 77-83-
dc.identifier.urihttp://hdl.handle.net/1942/33050-
dc.description.abstractBalance and gait impairments are highly prevalent in the neurological population. Although current rehabilitation strategies focus on motor learning principles, it is of interest to expand into embodied sensori-motor learning; that is learning through a continuous interaction between cognitive and motor systems, within an enriched sensory environment. Current developments in engineering allow for the development of enriched sensory environments through interactive feedback. The Augmented Movement Platform for Embodied Learning (AMPEL) was developed, both in terms of hardware and software by an inter-disciplinary circular participatory design strategy. The developed device was then tested for in-between session reliability for the outcome measures inter-step interval and total onset time. Ten healthy participants walked in four experimental paths on the device in two different sessions, and between session correlations were calculated. AMPEL was developed both in terms of software and hardware, with three Plug-In systems (auditory, visual, auditory + visual). The auditory Plug-In allows for flexible application of augmented feedback. The in-between session reliability of the outcomes measured by the system were between high and very high on all 4 walked paths, tested on ten healthy participants [mean age 41.8 +/- 18.5; BMI 24.8 +/- 6.1]. AMPEL shows full functionality, and has shown between session reliability for the measures of inter-step-intervals and total-onset-time in healthy controls during walking on different paths.-
dc.description.sponsorshipWe acknowledge the Methusalem project (awarded by the Flemish Government) at UGent and the UHasselt BOF grant for funding this study.-
dc.language.isoen-
dc.publisherSPRINGER-
dc.rightsSpringer Nature Switzerland AG 2020-
dc.subject.otherEmbodied environment-
dc.subject.otherTechnology-
dc.subject.otherAugmented feedback-
dc.subject.otherParticipatory design strategy-
dc.subject.otherPlug-in system-
dc.subject.otherAuditory and visual feedback-
dc.titleThe Augmented Movement Platform For Embodied Learning (AMPEL): development and reliability-
dc.typeJournal Contribution-
dc.identifier.epage83-
dc.identifier.issue1-
dc.identifier.spage77-
dc.identifier.volume15-
local.format.pages7-
local.bibliographicCitation.jcatA1-
dc.description.notesMoumdjian, L (corresponding author), Univ Ghent, IPEM Inst Psychoacoust & Elect Mus, Fac Arts & Philosophy, B-9000 Ghent, Belgium.; Moumdjian, L (corresponding author), UMSC Hasselt, Pelt, Belgium.; Moumdjian, L (corresponding author), Hasselt Univ, Fac Rehabil Sci, REVAL Rehabil Res Ctr, B-3500 Hasselt, Belgium.-
dc.description.noteslousin.moumdjian@uhasselt.be-
dc.description.otherMoumdjian, L (corresponding author), Univ Ghent, IPEM Inst Psychoacoust & Elect Mus, Fac Arts & Philosophy, B-9000 Ghent, Belgium ; UMSC Hasselt, Pelt, Belgium ; Hasselt Univ, Fac Rehabil Sci, REVAL Rehabil Res Ctr, B-3500 Hasselt, Belgium. lousin.moumdjian@uhasselt.be-
local.publisher.placeONE NEW YORK PLAZA, SUITE 4600, NEW YORK, NY, UNITED STATES-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1007/s12193-020-00354-8-
dc.identifier.isiWOS:000592580000001-
dc.contributor.orcidFeys, Peter/0000-0002-5680-5495-
local.provider.typewosris-
local.uhasselt.uhpubyes-
local.description.affiliation[Moumdjian, Lousin; Six, Joren; Schepers, Ivan; Lesaffre, Micheline; Leman, Marc] Univ Ghent, IPEM Inst Psychoacoust & Elect Mus, Fac Arts & Philosophy, B-9000 Ghent, Belgium.-
local.description.affiliation[Moumdjian, Lousin] UMSC Hasselt, Pelt, Belgium.-
local.description.affiliation[Moumdjian, Lousin; Vervust, Thomas; Feys, Peter] Hasselt Univ, Fac Rehabil Sci, REVAL Rehabil Res Ctr, B-3500 Hasselt, Belgium.-
local.description.affiliation[Feys, Peter] Univ Ghent, NaMiFab UGent Expertise Ctr Nano & Microfabricat, Dept Informat Technol, Technol Pk Zwijnaarde 126, B-9052 Ghent, Belgium.-
local.description.affiliation[Feys, Peter] Univ Ghent, Dept Elect & Informat Syst, Technol Pk Zwijnaarde 126, B-9052 Ghent, Belgium.-
local.uhasselt.internationalno-
item.fulltextWith Fulltext-
item.accessRightsOpen Access-
item.validationecoom 2021-
item.contributorMOUMDJIAN, Lousin-
item.contributorVervust, Thomas-
item.contributorSix, Joren-
item.contributorSchepers, Ivan-
item.contributorLesaffre, Micheline-
item.contributorFEYS, Peter-
item.contributorLeman, Marc-
item.fullcitationMOUMDJIAN, Lousin; Vervust, Thomas; Six, Joren; Schepers, Ivan; Lesaffre, Micheline; FEYS, Peter & Leman, Marc (2021) The Augmented Movement Platform For Embodied Learning (AMPEL): development and reliability. In: Journal on Multimodal User Interfaces (Printed), 15 (1), p. 77-83.-
crisitem.journal.issn1783-7677-
crisitem.journal.eissn1783-8738-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
REVISIONS_MANUSCRIPT_DevelopingAMPEL_FINAL.pdfPeer-reviewed author version406.92 kBAdobe PDFView/Open
s12193-020-00354-8.pdf
  Restricted Access
Published version799.09 kBAdobe PDFView/Open    Request a copy
Show simple item record

WEB OF SCIENCETM
Citations

3
checked on Sep 21, 2024

Page view(s)

40
checked on Aug 31, 2022

Download(s)

50
checked on Aug 31, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.