Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/33051
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGasior, Jakub S.-
dc.contributor.authorPawlowski, Mariusz-
dc.contributor.authorJelen, Piotr J.-
dc.contributor.authorRAMECKERS, Eugene-
dc.contributor.authorWilliams, Craig A.-
dc.contributor.authorMakuch, Robert-
dc.contributor.authorWerner, Bozena-
dc.date.accessioned2021-01-06T12:37:58Z-
dc.date.available2021-01-06T12:37:58Z-
dc.date.issued2020-
dc.date.submitted2020-12-22T13:56:29Z-
dc.identifier.citationINTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 17 (21) (Art N° 8026)-
dc.identifier.urihttp://hdl.handle.net/1942/33051-
dc.description.abstractThe reliability of handgrip strength (HGS) measurement has been confirmed in adults but has been sparsely addressed in pediatric populations. The aims of this study are twofold: to determine whether sex, age and/or hand-dominance influence the test-retest differences and to establish the reliability level of the HGS measurement in typical developing pediatric participants. A total of 338 participants aged 7-13 years were tested using a digital handgrip strength (HGS) dynamometer (Jamar Plus+ Dynamometer) by the same rater on two testing trials separated by a one-day interval between sessions. The HGS testing was conducted according to the American Society of Hand Therapists recommendations. Relative and absolute reliability statistics were calculated. Age influenced the test-retest difference of the HGS measurement as children compared to preadolescents had lower intraclass correlation coefficients (0.95 vs. 0.98), standard error of measurement (SEM) (0.74 vs. 0.78 kg), smallest detectable difference (SDD) (2.05 vs. 2.16 kg) and higher values of the percentage value of SEM (5.48 vs. 3.44%), normalized SDD (15.52 vs. 9.61%) and a mean difference between the test and retest values (0.50 vs. 0.02 kg) for the dominant hand. The results indicate that the protocol using the Jamar digital handgrip dynamometer is a reliable instrument to measure HGS in participants aged 7-13 years with typical development. Clinicians and researchers therefore can have confidence in determining the minimally clinical effect for HGS.-
dc.language.isoen-
dc.publisherMDPI-
dc.rights2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).-
dc.subject.otherchildren-
dc.subject.otheradolescents-
dc.subject.othermuscle strength-
dc.subject.othergrip strength-
dc.subject.otherdynamometer-
dc.subject.otherreliability-
dc.titleTest–Retest Reliability of Handgrip Strength Measurement in Children and Preadolescents-
dc.typeJournal Contribution-
dc.identifier.issue21-
dc.identifier.volume17-
local.format.pages11-
local.bibliographicCitation.jcatA1-
dc.description.notesGasior, JS (corresponding author), Med Univ Warsaw, Dept Pediat Cardiol & Gen Pediat, PL-02091 Warsaw, Poland.-
dc.description.notesjgasior@wum.edu.pl; pawlowskimariusz@o2.pl; piotr.jelen@wum.edu.pl;-
dc.description.noteseaa.rameckers@hetnet.nl; c.a.williams@exeter.ac.uk; r.makuch@uthrad.pl;-
dc.description.notesbozena.werner@wum.edu.pl-
dc.description.otherGasior, JS (corresponding author), Med Univ Warsaw, Dept Pediat Cardiol & Gen Pediat, PL-02091 Warsaw, Poland. jgasior@wum.edu.pl; pawlowskimariusz@o2.pl; piotr.jelen@wum.edu.pl; eaa.rameckers@hetnet.nl; c.a.williams@exeter.ac.uk; r.makuch@uthrad.pl; bozena.werner@wum.edu.pl-
local.publisher.placeST ALBAN-ANLAGE 66, CH-4052 BASEL, SWITZERLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr8026-
dc.identifier.doi10.3390/ijerph17218026-
dc.identifier.pmid33142693-
dc.identifier.isiWOS:000589164100001-
dc.contributor.orcidWilliams, Craig Anthony/0000-0002-1740-6248; makuch,-
dc.contributor.orcidrobert/0000-0001-5447-6854; Gasior, Jakub S./0000-0002-2009-2200; Jelen,-
dc.contributor.orcidPiotr/0000-0002-0973-7143-
local.provider.typewosris-
local.uhasselt.uhpubyes-
local.description.affiliation[Gasior, Jakub S.; Werner, Bozena] Med Univ Warsaw, Dept Pediat Cardiol & Gen Pediat, PL-02091 Warsaw, Poland.-
local.description.affiliation[Pawlowski, Mariusz] Med Univ Warsaw, Bielanski Hosp, Cardiol Clin Physiotherapy Div, Fac Med 2, PL-01809 Warsaw, Poland.-
local.description.affiliation[Jelen, Piotr J.] Med Univ Warsaw, Dept Biophys & Human Physiol, PL-02004 Warsaw, Poland.-
local.description.affiliation[Rameckers, Eugene A.] Maastricht Univ, Res Sch CAPHRI, Dept Rehabil Med, NL-6229 ER Maastricht, Netherlands.-
local.description.affiliation[Rameckers, Eugene A.] Univ Professionals, Dept Pediat Phys Therapy, AVANSplus, NL-4818 CP Breda, Netherlands.-
local.description.affiliation[Rameckers, Eugene A.] Adelante Ctr Expertise Rehabil & Audiol, NL-6432 CC Hoensbroek, Netherlands.-
local.description.affiliation[Rameckers, Eugene A.] Hasselt Univ, Fac Rehabil Sci, Pediat Rehabil, B-3590 Diepenbeek, Belgium.-
local.description.affiliation[Williams, Craig A.] Univ Exeter, Coll Life & Environm Sci Sport & Hlth Sci, Childrens Hlth & Exercise Res Ctr, St Lukes Campus, Exeter EX1 2LU, Devon, England.-
local.description.affiliation[Makuch, Robert] Kazimierz Pulaski Univ Technol & Humanities Radom, Dept Phys Educ, PL-26600 Radom, Poland.-
item.validationecoom 2021-
item.contributorGasior, Jakub S.-
item.contributorPawlowski, Mariusz-
item.contributorJelen, Piotr J.-
item.contributorRAMECKERS, Eugene-
item.contributorWilliams, Craig A.-
item.contributorMakuch, Robert-
item.contributorWerner, Bozena-
item.accessRightsOpen Access-
item.fullcitationGasior, Jakub S.; Pawlowski, Mariusz; Jelen, Piotr J.; RAMECKERS, Eugene; Williams, Craig A.; Makuch, Robert & Werner, Bozena (2020) Test–Retest Reliability of Handgrip Strength Measurement in Children and Preadolescents. In: INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 17 (21) (Art N° 8026).-
item.fulltextWith Fulltext-
crisitem.journal.issn1661-7827-
crisitem.journal.eissn1660-4601-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
ijerph-17-08026.pdfPublished version937.76 kBAdobe PDFView/Open
Show simple item record

WEB OF SCIENCETM
Citations

18
checked on Apr 30, 2024

Page view(s)

26
checked on May 30, 2022

Download(s)

8
checked on May 30, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.