dc.identifier.citationANALYTICAL BIOCHEMISTRY, 245(1). p. 28-37-
dc.identifier.issn0003-2697-
dc.identifier.urihttp://hdl.handle.net/1942/3308-
dc.description.abstractA test based on time-resolved fluorescence experiments is proposed to assess the interference of an excited-state reaction with the fluorimetric determination of the ground-state dissociation constant K-d of ion subset of fluorescent indicator complexes. If an inflection point occurs in the plot of the fluorescence signal vs -log [ion] in the concentration range of the ion where both decay times are invariant, this inflection point can be associated With the correct K-d. In contrast, the inflection point(s) in the concentration range where the decay times vary cannot be attributed to K-d. The test is applied to the fluorescent ion indicators SBFI (for Na+), PBFI (for K+), and Fura-2 (for Ca2+). In all three cases the decay times are invariant in the physiological concentration ranges of the respective ions, indicating that the fluorimetrically determined K-d values are actually the true K-d values. (C) 1997 Academic Press.-
dc.language.isoen-
dc.publisherACADEMIC PRESS INC JNL-COMP SUBSCRIPTIONS-
dc.titlePotential misevaluation of the ground-state dissociation constant from fluorimetric titrations: Application to the ion indicators SBFI, PBFI, and Fura-2-
dc.typeJournal Contribution-
dc.identifier.epage37-
dc.identifier.issue1-
dc.identifier.spage28-
dc.identifier.volume245-
local.format.pages10-
dc.description.notesNICHOLAS COPERNICUS UNIV,INST PHYS,PL-87100 TORUN,POLAND. KATHOLIEKE UNIV LEUVEN,DEPT CHEM,B-3001 HEVERLEE,BELGIUM. LIMBURGS UNIV CTR,B-3590 DIEPENBEEK,BELGIUM.-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.bibliographicCitation.oldjcatA1-
dc.identifier.doi10.1006/abio.1996.9932-
dc.identifier.isiA1997WE92400004-
item.accessRightsClosed Access-
item.contributorKowalczyk, A-
item.contributorBoens, N-
item.contributorMeuwis, K-
item.contributorAMELOOT, Marcel-
item.fullcitationKowalczyk, A; Boens, N; Meuwis, K & AMELOOT, Marcel (1997) Potential misevaluation of the ground-state dissociation constant from fluorimetric titrations: Application to the ion indicators SBFI, PBFI, and Fura-2. In: ANALYTICAL BIOCHEMISTRY, 245(1). p. 28-37.-
item.fulltextNo Fulltext-
Appears in Collections:Research publications
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.