Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/33151
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSanchez, Esther-
dc.contributor.authorSchilling, Christoph-
dc.contributor.authorGrupp, Thomas M.-
dc.contributor.authorGiurea, Alexander-
dc.contributor.authorWyers, Caroline-
dc.contributor.authorVAN DEN BERGH, Joop-
dc.contributor.authorVerdonschot, Nico-
dc.contributor.authorJanssen, Dennis-
dc.date.accessioned2021-01-22T14:37:58Z-
dc.date.available2021-01-22T14:37:58Z-
dc.date.issued2021-
dc.date.submitted2021-01-21T09:30:52Z-
dc.identifier.citationJournal of the Mechanical Behavior of Biomedical Materials, 113 (Art N° 104189)-
dc.identifier.issn1751-6161-
dc.identifier.urihttp://hdl.handle.net/1942/33151-
dc.description.abstractCementless femoral total knee arthroplasty (TKA) components use a press-fit (referred to as interference fit) to achieve initial fixation. A higher interference fit could lead to a superior fixation, but it could also introduce more damage to the bone during implantation. The purpose of the current study was to investigate the effect of interference fit on the micromotions and gap opening/closing at the bone-implant interface. Experimental tests were performed in six pairs of cadaveric femurs implanted with femoral components using a low interference fit of 350 mu m and a high interference fit of 700 mu m. The specimens were subjected to the peak loads of gait and squat, based on the Orthoload dataset. Digital Image Correlation (DIC) was used to measure the micromotions and opening/closing in different regions of interest (ROIs). Two linear mixed-effect statistical models were created with micromotions and gap opening/closing as dependent variables. ROIs, loading conditions, and implant designs as independent variables, and cadaver specimens as random intercepts. The results revealed no significant difference between the two interference fit implants for micromotions (p = 0.837 for gait and p = 0.065 for squat), nor for the gap opening/closing (p = 0.748 for gait and p = 0.561 for squat). In contrast, significant differences were found between loading and most of the ROIs in both dependent variables (p < 0.0001). Additionally, no difference in bone deformation was found between low and high interference fit. Changing interference between either 350 mu m or 700 mu m did not affect the primary stability of a femoral TKA component. There could be an interference fit threshold beyond which fixation does not further improve.-
dc.description.sponsorshipA research grant from Aesculap (Aesculap, B. Braun, Tuttlingen, Germany) supported this work. We would like to thank Dr. Thomas Hoogeboom for his help in developing the statistical model, Richard van Swam for the help and support during the experimental tests, Leon Driessen for all the segmentation work with the HR-pQCT scans, Max Bakker for the Matlab support, and Erik de Vries for the surface morphology measurements. We are also thankful to Justine Eerden for her collaboration in this project.-
dc.language.isoen-
dc.publisherELSEVIER-
dc.rights2020 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).-
dc.subject.otherInterference fit-
dc.subject.otherCementless fixation-
dc.subject.otherMicromotion-
dc.subject.otherInterfacial gap-
dc.subject.otherDigital image correlation-
dc.subject.otherBone deformation-
dc.titleThe effect of different interference fits on the primary fixation of a cementless femoral component during experimental testing-
dc.typeJournal Contribution-
dc.identifier.volume113-
local.format.pages7-
local.bibliographicCitation.jcatA1-
dc.description.notesSanchez, E (corresponding author), Orthopaed Res Lab 611,Geert Gmotepl Zuid 30, NL-6525 GA Nijmegen, Netherlands.-
dc.description.notesEsther.SanchezGarza@radboudumc.nl-
dc.description.otherSanchez, E (corresponding author), Orthopaed Res Lab 611,Geert Gmotepl Zuid 30, NL-6525 GA Nijmegen, Netherlands. Esther.SanchezGarza@radboudumc.nl-
local.publisher.placeRADARWEG 29, 1043 NX AMSTERDAM, NETHERLANDS-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr104189-
dc.identifier.doi10.1016/j.jmbbm.2020.104189-
dc.identifier.pmid33158789-
dc.identifier.isiWOS:000599657400003-
dc.contributor.orcidvan den Bergh, Joop/0000-0003-3984-2232; Janssen,-
dc.contributor.orcidDennis/0000-0003-0743-9975-
dc.identifier.eissn1878-0180-
local.provider.typewosris-
local.uhasselt.uhpubyes-
local.description.affiliation[Sanchez, Esther; Verdonschot, Nico; Janssen, Dennis] Radboud Univ Nijmegen Med Ctr, Radboud Inst Hlth Sci, Orthopaed Res Lab, Nijmegen, Netherlands.-
local.description.affiliation[Schilling, Christoph; Grupp, Thomas M.] Aesculap AG, Res & Dev, Tuttlingen, Germany.-
local.description.affiliation[Grupp, Thomas M.] Ludwig Maximilian Univ Munich, Dept Orthopaed Surg Phys Med & Rehabil, Campus Grosshadern, Munich, Germany.-
local.description.affiliation[Giurea, Alexander] Med Univ Vienna, Dept Orthoped, Vienna, Austria.-
local.description.affiliation[Wyers, Caroline; van den Bergh, Joop] VieCuri Med Ctr, Dept Internal Med, Venlo, Netherlands.-
local.description.affiliation[Wyers, Caroline; van den Bergh, Joop] Maastricht Univ Med Ctr MUMC, NUTRIM Sch Nutr & Translat Res Metab, Dept Internal Med, Maastricht, Netherlands.-
local.description.affiliation[van den Bergh, Joop] Hasselt Univ, Biomed Res Ctr, Diepenbeek, Belgium.-
local.description.affiliation[Verdonschot, Nico] Univ Twente, Fac Engn Technol, Lab Biomech Engn, Enschede, Netherlands.-
local.uhasselt.internationalyes-
item.fullcitationSanchez, Esther; Schilling, Christoph; Grupp, Thomas M.; Giurea, Alexander; Wyers, Caroline; VAN DEN BERGH, Joop; Verdonschot, Nico & Janssen, Dennis (2021) The effect of different interference fits on the primary fixation of a cementless femoral component during experimental testing. In: Journal of the Mechanical Behavior of Biomedical Materials, 113 (Art N° 104189).-
item.contributorSanchez, Esther-
item.contributorSchilling, Christoph-
item.contributorGrupp, Thomas M.-
item.contributorGiurea, Alexander-
item.contributorWyers, Caroline-
item.contributorVAN DEN BERGH, Joop-
item.contributorVerdonschot, Nico-
item.contributorJanssen, Dennis-
item.validationecoom 2022-
item.accessRightsOpen Access-
item.fulltextWith Fulltext-
crisitem.journal.issn1751-6161-
crisitem.journal.eissn1878-0180-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
1-s2.0-S1751616120307311-main.pdfPublished version6.1 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.