Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/33520
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSONG, Dandan-
dc.contributor.authorShujaat, Sohaib-
dc.contributor.authorHuang, Yan-
dc.contributor.authorVan Dessel, Jeroen-
dc.contributor.authorPOLITIS, Constantinus-
dc.contributor.authorLAMBRICHTS, Ivo-
dc.contributor.authorJacobs, Reinhilde-
dc.date.accessioned2021-02-24T11:26:25Z-
dc.date.available2021-02-24T11:26:25Z-
dc.date.issued2021-
dc.date.submitted2021-02-18T19:02:49Z-
dc.identifier.citationInternational Journal of Implant Dentistry, 7 (1), (Art N° 11)-
dc.identifier.urihttp://hdl.handle.net/1942/33520-
dc.description.abstractBackground: Bone-to-implant contact ratio (BIC%) plays a critical role in secondary stability of osseointegrated dental implants. The aim of this study was to identify the correlation of 2D/3D micro-CT images with histology as a gold standard for evaluating BIC% and to investigate the influence of the platelet-rich plasma (PRP) and platelet-poor plasma (PPP) on 3D BIC% following delayed implant placement with delayed loading (DIP+DL). Methods: Nine beagle dogs were recruited. Following bilateral extraction of mandibular 3rd premolar, 4th premolar, and 1st molar, 54 screw-type titanium implants were inserted and randomly divided into one control and two test groups based on a split-mouth design. The control group involved DIP+DL (n = 18) and both test groups included DIP+DL with local application of PRP (n = 18) and PPP (n = 18). A BIC analysis was performed utilizing 2D histomorphometry and 2D/3D micro-CT. Following identification of correlation between histology and 2D/3D micro-CT images, a 3D micro-CT assessment of the 3D BIC% at three follow-up time-points (1, 3, and 6 months) was carried out for observing the influence of PRP and PPP on BIC.-
dc.description.sponsorshipThis work was supported by a Sichuan Province Science and Technology Support Program (2016SZ0010). DS received fellowship support from China Scholarship Council (201708210187). HY is a postdoctoral (11.N3.615N) and JVD is a predoctoral (11.ZU.117N) FWO-research fellow.-
dc.language.isoen-
dc.publisherSPRINGER JAPAN KK-
dc.rightsOpen Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.-
dc.subject.otherPlatelet-rich plasma-
dc.subject.otherOsseointegration-
dc.subject.otherBone-implant interface-
dc.subject.otherX-ray micro-CT-
dc.subject.otherDental implants-
dc.titleEffect of platelet-rich and platelet-poor plasma on 3D bone-to-implant contact: a preclinical micro-CT study-
dc.typeJournal Contribution-
dc.identifier.issue1-
dc.identifier.volume7-
local.bibliographicCitation.jcatA1-
local.publisher.placeSHIROYAMA TRUST TOWER 5F, 4-3-1 TORANOMON, MINATO-KU, TOKYO, 105-6005, JAPAN-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr11-
dc.identifier.doi10.1186/s40729-021-00291-5-
dc.identifier.pmid33598799-
dc.identifier.isiWOS:000619223600001-
dc.identifier.eissn2198-4034-
local.provider.typeCrossRef-
local.uhasselt.uhpubyes-
local.uhasselt.internationalyes-
item.fullcitationSONG, Dandan; Shujaat, Sohaib; Huang, Yan; Van Dessel, Jeroen; POLITIS, Constantinus; LAMBRICHTS, Ivo & Jacobs, Reinhilde (2021) Effect of platelet-rich and platelet-poor plasma on 3D bone-to-implant contact: a preclinical micro-CT study. In: International Journal of Implant Dentistry, 7 (1), (Art N° 11).-
item.contributorSONG, Dandan-
item.contributorShujaat, Sohaib-
item.contributorHuang, Yan-
item.contributorVan Dessel, Jeroen-
item.contributorPOLITIS, Constantinus-
item.contributorLAMBRICHTS, Ivo-
item.contributorJacobs, Reinhilde-
item.validationecoom 2022-
item.accessRightsOpen Access-
item.fulltextWith Fulltext-
crisitem.journal.eissn2198-4034-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
s40729-021-00291-5.pdfPublished version1.76 MBAdobe PDFView/Open
Show simple item record

WEB OF SCIENCETM
Citations

1
checked on Sep 20, 2024

Page view(s)

32
checked on Jun 14, 2022

Download(s)

14
checked on Jun 14, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.