dc.description.abstractRationale Selected ion flow tube mass spectrometry (SIFT-MS) is versatile, rapidly provides result output and determines a wide range of volatiles, making it suitable for biomedical applications. When direct sampling into the SIFT-MS instrument is impractical, combining thermal desorption (TD) and SIFT-MS might offer a solution as it allows sample storage on sorbent tubes for later analysis. This work compares off-line TD SIFT-MS and real-time SIFT-MS for the quantification of selected breath volatiles. Methods Ten healthy non-smoking individuals provided 60 breath samples per method. For off-line analysis, breath was collected onto sorbent tubes via a breath sampler provided with filtered inspiratory air. After TD, samples were re-collected in Tedlar bags which were then connected to the SIFT-MS instrument. For real-time analysis, breath was sampled directly into the instrument. In both cases the analytical method included a total of 155 product ions, and 14 selected volatiles were quantified. The agreement between the methods was assessed using Pearson correlation coefficients and Bland-Altman plots. Results Overall, correlations between real-time and off-line analysis were moderate to very strong (r = 0.43-0.92) depending on the volatile of interest, except for 2,3-butanedione and styrene. The difference between real-time and off-line measured breath concentrations (average bias) ranged between -14.57 and 20.48 ppbv. For acetone and isoprene, it was 251.53 and 31.9 ppbv, respectively. Conclusions Real-time SIFT-MS and off-line TD SIFT-MS for quantification of selected breath volatiles did not show optimal agreement. Analyzing a multitude of analytes in breath via direct exhalation into a SIFT-MS instrument for real-time analysis is challenging. On the other hand, off-line analysis using a breath collection device also has its issues such as possible sample losses due to selective absorption depending on the sorbent used or during desorption and transfer to the instrument. Despite these drawbacks, both methods were moderately well correlated.-
dc.description.sponsorshipThe authors thank all the volunteers for participating in this study. The authors also thank the coordinator and other parties of the Peppermint Consortium for the opportunity to participate in the benchmarking study. M.V.E. was supported by the University Research Fund of the University of Antwerp. G.S. is supported by the Limburg Clinical Research Center (LCRC) UHasselt-ZOL-Jessa, supported by the foundation Limburg Sterk Merk, province of Limburg, Flemish government, Hasselt University, Jessa Hospital and Ziekenhuis Oost-Limburg.-
dc.language.isoen-
dc.publisherWILEY-
dc.rights2020 John Wiley & Sons Ltd-
dc.subject.otherAdult-
dc.subject.otherBreath Tests-
dc.subject.otherFemale-
dc.subject.otherHumans-
dc.subject.otherMale-
dc.subject.otherMass Spectrometry-
dc.subject.otherMiddle Aged-
dc.subject.otherVolatile Organic Compounds-
dc.subject.otherYoung Adult-
dc.titleReal-time versus thermal desorption selected ion flow tube mass spectrometry for quantification of breath volatiles-
dc.typeJournal Contribution-
dc.identifier.issue4-
dc.identifier.volume35-
local.format.pages9-
local.bibliographicCitation.jcatA1-
dc.description.notesKoppen, G (corresponding author), VITO Hlth, Flemish Inst Technol Res, B-2400 Mol, Belgium.-
dc.description.notesgudrun.koppen@vito.be-
dc.description.otherKoppen, G (corresponding author), VITO Hlth, Flemish Inst Technol Res, B-2400 Mol, Belgium. gudrun.koppen@vito.be-
local.publisher.place111 RIVER ST, HOBOKEN 07030-5774, NJ USA-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnre8994-
dc.identifier.doi10.1002/rcm.8994-
dc.identifier.pmid33125775-
dc.identifier.isiWOS:000609901100010-
dc.contributor.orcidSlingers, Gitte/0000-0002-7021-5125-
dc.identifier.eissn1097-0231-
local.provider.typewosris-
local.uhasselt.uhpubyes-
local.description.affiliation[Slingers, Gitte; Lindekens, Jill; Raes, Marc] Hasselt Univ, LCRC, Fac Med & Life Sci, Agoralaan, B-3590 Diepenbeek, Belgium.-
local.description.affiliation[Slingers, Gitte; Vanden Eede, Martin; Spruyt, Maarten; Goelen, Eddy; Koppen, Gudrun] VITO Hlth, Flemish Inst Technol Res, B-2400 Mol, Belgium.-
local.description.affiliation[Slingers, Gitte; Raes, Marc] Jessa Hosp, Paediat, B-3500 Stadsomvaart, Hasselt, Belgium.-
local.description.affiliation[Vanden Eede, Martin] Univ Antwerp, Lab Expt Med & Paediat, Univ Pl, B-2650 Edegem, Belgium.-
local.uhasselt.internationalno-
item.validationecoom 2022-
item.fulltextWith Fulltext-
item.fullcitationSLINGERS, Gitte; Vanden Eede, Martin; Lindekens, Jill; Spruyt, Maarten; Goelen, Eddy; RAES, Marc & Koppen, Gudrun (2021) Real-time versus thermal desorption selected ion flow tube mass spectrometry for quantification of breath volatiles. In: RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 35 (4) (Art N° e8994).-
item.accessRightsRestricted Access-
item.contributorSLINGERS, Gitte-
item.contributorVanden Eede, Martin-
item.contributorLindekens, Jill-
item.contributorSpruyt, Maarten-
item.contributorGoelen, Eddy-
item.contributorRAES, Marc-
item.contributorKoppen, Gudrun-
crisitem.journal.issn0951-4198-
crisitem.journal.eissn1097-0231-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
rcm.8994.pdf
  Restricted Access
Published version2.1 MBAdobe PDFView/Open    Request a copy
Show simple item record

WEB OF SCIENCETM
Citations

9
checked on Jul 10, 2024

Page view(s)

22
checked on May 24, 2022

Download(s)

4
checked on May 24, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.