Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/34048
Full metadata record
DC FieldValueLanguage
dc.contributor.author-Hubert, M. De Saint-
dc.contributor.authorAngelis, C. De-
dc.contributor.authorKnezevic, Z.-
dc.contributor.authorMichalec, B.-
dc.contributor.authorRENIERS, Brigitte-
dc.contributor.authorPyszka, E.-
dc.contributor.authorStolarczyk, L.-
dc.contributor.authorSwakon, J.-
dc.contributor.authorFoltynska, G.-
dc.contributor.authorWochnik, A.-
dc.contributor.authorParisi, A.-
dc.contributor.authorMajer, M.-
dc.contributor.authorHarrison, R. M.-
dc.contributor.authorKopec, R.-
dc.contributor.authorVanhavere, F.-
dc.contributor.authorOlko, P.-
dc.date.accessioned2021-05-25T15:06:27Z-
dc.date.available2021-05-25T15:06:27Z-
dc.date.issued2021-
dc.date.submitted2021-05-11T11:38:47Z-
dc.identifier.citationPhysica Medica-European Journal of Medical Physics, 82 , p. 134 -143-
dc.identifier.issn11201797-
dc.identifier.urihttp://hdl.handle.net/1942/34048-
dc.description.abstractThe lack of mailed dosimetry audits of proton therapy centres in Europe has encouraged researchers of EURADOS Working Group 9 (WG9) to compare response of several existing passive detector systems in therapeutic pencil beam scanning. Alanine Electron Paramagnetic Resonance dosimetry systems from 3 different institutes (ISS, Italy; UH, Belgium and IFJ PAN, Poland), natLiF:Mg, Ti (MTS-N) and natLiF:Mg, Cu, P (MCP-N) thermoluminescent dosimeters (TLDs), GD-352M radiophotoluminescent glass dosimeters (RPLGDs) and Al2O3:C optically stimulated dosimeters (OSLDs) were evaluate. Dosimeter repeatability, batch reproducibility and response in therapeutic Pencil Beam Scanning were verified for implementation as mail auditing system. Alanine detectors demonstrated the lowest linear energy transfer (LET) dependence with an agreement between measured and treatment planning system (TPS) dose below 1%. The OSLDs measured on average a 6.3% lower dose compared to TPS calculation, with no significant difference between varying modulations and ranges. Both GD-352M and MCP-N measured a lower dose than the TPS and luminescent response was dependent on the LET of the therapeutic proton beam. Thermoluminescent response of MTS-N was also found to be dependent on the LET and a higher dose than TPS was measured with the most pronounced increase of 11%. As alanine detectors are characterized by the lowest energy dependence for different parameters of therapeutic pencil beam scanning they are suitable candidates for mail auditing in proton therapy. The response of luminescence detector systems have shown promises even though more careful calibration and corrections are needed for its implementation as part of a mailed dosimetry audit system.-
dc.language.isoen-
dc.publisherELSEVIER SCI LTD-
dc.rights2021 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.-
dc.subject.otherAlanine-
dc.subject.otherLuminescence dosimetry-
dc.subject.otherMail auditing-
dc.subject.otherProton therapy-
dc.titleCharacterization of passive dosimeters in proton pencil beam scanning – A EURADOS intercomparison for mailed dosimetry audits in proton therapy centres-
dc.typeJournal Contribution-
dc.identifier.epage143-
dc.identifier.spage134-
dc.identifier.volume82-
local.format.pages10-
local.bibliographicCitation.jcatA1-
dc.description.notesDe Saint-Hubert, M (corresponding author), Belgian Nucl Res Ctr SCK CEN, Boeretang 200, BE-2400 Mol, Belgium.-
dc.description.notesmdsainth@sckcen.be-
dc.description.otherDe Saint-Hubert, M (corresponding author), Belgian Nucl Res Ctr SCK CEN, Boeretang 200, BE-2400 Mol, Belgium. mdsainth@sckcen.be-
local.publisher.placeTHE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, OXON, ENGLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1016/j.ejmp.2021.01.073-
dc.identifier.pmid33611050-
dc.identifier.isiWOS:000637335600006-
dc.contributor.orcidDE ANGELIS, CINZIA/0000-0002-0546-3608; Olko, Pawel/0000-0001-5554-8178;-
dc.contributor.orcidSwakon, Jan/0000-0001-9262-7326-
dc.identifier.eissn1724-191X-
local.provider.typewosris-
local.uhasselt.uhpubyes-
local.description.affiliation[-Hubert, M. De Saint; Parisi, A.; Vanhavere, F.] Belgian Nucl Res Ctr SCK CEN, Boeretang 200, BE-2400 Mol, Belgium.-
local.description.affiliation[Angelis, C. De] Ist Super Sanit ISS, Viale Regina Elena 299, I-00161 Rome, Italy.-
local.description.affiliation[Knezevic, Z.; Majer, M.] Ruder Boskovic Inst RBI, Bijenicka 54, Zagreb, Croatia.-
local.description.affiliation[Michalec, B.; Pyszka, E.; Stolarczyk, L.; Swakon, J.; Foltynska, G.; Wochnik, A.; Kopec, R.; Olko, P.] Polish Acad Sci IFJ PAN, Inst Nucl Phys, Radzikowskiego 152, PL-31342 Krakow, Poland.-
local.description.affiliation[Reniers, B.] Univ Hasselt UH, Res Grp NuTeC, Agoralaan Gebouw H, B-3590 Diepenbeek, Belgium.-
local.description.affiliation[Harrison, R. M.] Univ Newcastle, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England.-
local.uhasselt.internationalyes-
item.validationecoom 2022-
item.contributor-Hubert, M. De Saint-
item.contributorAngelis, C. De-
item.contributorKnezevic, Z.-
item.contributorMichalec, B.-
item.contributorRENIERS, Brigitte-
item.contributorPyszka, E.-
item.contributorStolarczyk, L.-
item.contributorSwakon, J.-
item.contributorFoltynska, G.-
item.contributorWochnik, A.-
item.contributorParisi, A.-
item.contributorMajer, M.-
item.contributorHarrison, R. M.-
item.contributorKopec, R.-
item.contributorVanhavere, F.-
item.contributorOlko, P.-
item.accessRightsOpen Access-
item.fullcitation-Hubert, M. De Saint; Angelis, C. De; Knezevic, Z.; Michalec, B.; RENIERS, Brigitte; Pyszka, E.; Stolarczyk, L.; Swakon, J.; Foltynska, G.; Wochnik, A.; Parisi, A.; Majer, M.; Harrison, R. M.; Kopec, R.; Vanhavere, F. & Olko, P. (2021) Characterization of passive dosimeters in proton pencil beam scanning – A EURADOS intercomparison for mailed dosimetry audits in proton therapy centres. In: Physica Medica-European Journal of Medical Physics, 82 , p. 134 -143.-
item.fulltextWith Fulltext-
crisitem.journal.issn1120-1797-
crisitem.journal.eissn1724-191X-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
1-s2.0-S1120179721000764-main.pdfPublished version2.3 MBAdobe PDFView/Open
Show simple item record

WEB OF SCIENCETM
Citations

5
checked on May 2, 2024

Page view(s)

54
checked on Sep 7, 2022

Download(s)

12
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.