Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/34652
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAnantharajah, Ahalieyah-
dc.contributor.authorGlupczynski, Youri-
dc.contributor.authorHoebeke, Martin-
dc.contributor.authorBogaerts, Pierre-
dc.contributor.authorDeclercq, Philippe-
dc.contributor.authorDenis, Olivier-
dc.contributor.authorDescy, Julie-
dc.contributor.authorFloré, Katelijne-
dc.contributor.authorMAGERMAN, Koen-
dc.contributor.authorRodriguez-Villalobos, Hector-
dc.contributor.authorVan den Abeele, Anne-Marie-
dc.contributor.authorHuang, Te-Din-
dc.date.accessioned2021-08-08T14:23:59Z-
dc.date.available2021-08-08T14:23:59Z-
dc.date.issued2021-
dc.date.submitted2021-07-08T09:18:39Z-
dc.identifier.citationEuropean journal of clinical microbiology & infectious diseases (Print), 40 (3) , p. 575 -579-
dc.identifier.urihttp://hdl.handle.net/1942/34652-
dc.description.abstractPurpose Broth microdilution (BMD) stays as the reference testing method for determination of antimicrobial susceptibility testing (AST) to colistin and is considered essential for patient management and for monitoring of colistin resistance. This multicenter study aimed to evaluate the performance of automated systems for colistin AST among Enterobacterales as an alternative for BMD since the majority of laboratories use automated systems as first-line method. Methods Twenty colistin resistant (COL-R) including 10 MCR producers and 10 colistin-susceptible (COL-S) Enterobacterales isolates were blindly tested for colistin susceptibility with the routine automated AST systems used by 8 laboratories (3 with BD Phoenix, 3 with Vitek2 and 2 with MicroScan). Additionally, 3 reference strains (E. coliATCC 25922,E. coliNCTC 13846, and one COL-R mcr-negativeK. pneumoniaeM/14750) were tested in triplicate by each laboratory. Results and conclusion Results were compared with BMD performed at the reference laboratory. BD Phoenix and MicroScan automated AST systems provide accurate and reproducible categorical results for the testing of colistin in Enterobacterales. However, Vitek2 system showed poor performance for the detection of COL-R isolates especially those with MICs close to the susceptibility breakpoint (categorical agreement of 88% and precision categorical agreement of 81%).-
dc.language.isoen-
dc.titleMulticenter study of automated systems for colistin susceptibility testing-
dc.typeJournal Contribution-
dc.identifier.epage579-
dc.identifier.issue3-
dc.identifier.spage575-
dc.identifier.volume40-
local.bibliographicCitation.jcatA1-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1007/s10096-020-04059-4-
dc.identifier.isiWOS:000575779500002-
dc.contributor.orcidRodriguez-Villalobos, Hector/0000-0003-3041-1591-
local.provider.typewosris-
local.uhasselt.internationalno-
item.contributorAnantharajah, Ahalieyah-
item.contributorGlupczynski, Youri-
item.contributorHoebeke, Martin-
item.contributorBogaerts, Pierre-
item.contributorDeclercq, Philippe-
item.contributorDenis, Olivier-
item.contributorDescy, Julie-
item.contributorFloré, Katelijne-
item.contributorMAGERMAN, Koen-
item.contributorRodriguez-Villalobos, Hector-
item.contributorVan den Abeele, Anne-Marie-
item.contributorHuang, Te-Din-
item.fulltextNo Fulltext-
item.fullcitationAnantharajah, Ahalieyah; Glupczynski, Youri; Hoebeke, Martin; Bogaerts, Pierre; Declercq, Philippe; Denis, Olivier; Descy, Julie; Floré, Katelijne; MAGERMAN, Koen; Rodriguez-Villalobos, Hector; Van den Abeele, Anne-Marie & Huang, Te-Din (2021) Multicenter study of automated systems for colistin susceptibility testing. In: European journal of clinical microbiology & infectious diseases (Print), 40 (3) , p. 575 -579.-
item.accessRightsClosed Access-
crisitem.journal.issn0934-9723-
crisitem.journal.eissn1435-4373-
Appears in Collections:Research publications
Show simple item record

WEB OF SCIENCETM
Citations

5
checked on Apr 30, 2024

Page view(s)

58
checked on Jun 19, 2023

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.