Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/35729
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSouza, Keila L.-
dc.contributor.authorda Silva, André T.-
dc.contributor.authorGOUVEIA HENRIQUES, Jose-
dc.contributor.authorVellasco, Pedro C. G.-
dc.contributor.authorRodrigues, Monique C.-
dc.date.accessioned2021-10-28T09:32:57Z-
dc.date.available2021-10-28T09:32:57Z-
dc.date.issued2021-
dc.date.submitted2021-10-22T12:58:17Z-
dc.identifier.citationJesse (Ed.). , p. 666 -674-
dc.identifier.issn2509-7075-
dc.identifier.issn2509-7075-
dc.identifier.urihttp://hdl.handle.net/1942/35729-
dc.description.abstractComposite structures have been applied more frequently because they are an economical structural solution with excellent structural performance. The interaction is guaranteed with the use of elements that transfer the forces between these two materials. The most common mechanical connections between steel and concrete are made through shear connectors. Some of the connectors types used nowadays are stud bolt, U-profiles, Crestbond, Perfobond and T-Perfobond. Eurocode 4 prescribes that a connector has to possess a minimal ductility, one of the main requirements to shear connectors. The current Perfobond presents excellent resistant capacity, but low deformation capacity, contradicting what is prescribed by the code. This paper aims to study a Tubular Perforbond connector by analyzing the parameters that can influence its resistance and deformation capacity, applying FEM through Abaqus software, to simulate the composite structural, mechanical behaviour. When comparing the Tubular Perfobond connector with the Perfobond connector, it was possible to observe that the tubular connectors presented a substantial deformation capacity after peak load, while attending the connector ductility requirements. The use of Tubular connectors also decreased the concrete crushing propagation.-
dc.language.isoen-
dc.publisher-
dc.relation.ispartofseriesEurosteel - European Conference on Steel and Composite Structures-
dc.subject.otherComposite beams-
dc.subject.otherTubular Perfobond shear connector-
dc.subject.otherPushout test-
dc.subject.otherNonlinear analysis-
dc.subject.otherFinite element method Correspondence-
dc.titleNumerical evaluation of tubular perfobond shear connectors-
dc.typeProceedings Paper-
local.bibliographicCitation.authorsJesse-
local.bibliographicCitation.conferencedate1 - 3 September 2021-
local.bibliographicCitation.conferencenameEUROSTEEL 2021 Sheffield – Steel‘s coming home-
local.bibliographicCitation.conferenceplaceSheffiled-
dc.identifier.epage674-
dc.identifier.issue2 - 4-
dc.identifier.spage666-
dc.identifier.volume4-
local.format.pages9-
local.bibliographicCitation.jcatC1-
local.type.refereedRefereed-
local.type.specifiedProceedings Paper-
dc.identifier.doi10.1002/cepa.1346-
dc.identifier.eissn-
local.provider.typePdf-
local.uhasselt.uhpubyes-
local.uhasselt.internationalyes-
item.fulltextWith Fulltext-
item.accessRightsRestricted Access-
item.fullcitationSouza, Keila L.; da Silva, André T.; GOUVEIA HENRIQUES, Jose; Vellasco, Pedro C. G. & Rodrigues, Monique C. (2021) Numerical evaluation of tubular perfobond shear connectors. In: Jesse (Ed.). , p. 666 -674.-
item.contributorSouza, Keila L.-
item.contributorda Silva, André T.-
item.contributorGOUVEIA HENRIQUES, Jose-
item.contributorVellasco, Pedro C. G.-
item.contributorRodrigues, Monique C.-
crisitem.journal.issn2509-7075-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Souza K L et al Numerical evaluation of tubular perfobond shear connectors_cepa.1346.pdf
  Restricted Access
Published version2.04 MBAdobe PDFView/Open    Request a copy
Show simple item record

Page view(s)

26
checked on Sep 7, 2022

Download(s)

4
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.