dc.description.abstractModern masonry structures, apart from having a load-bearing function, are more and more subjected to additional non-structural requirements related to, e.g., thermal insulation and moisture control. This has respectively led to the introduction of thermal break layers, in practice often executed using autoclaved aerated concrete (AAC) blocks, and damp proof courses (DPC) in masonry walls. These modifications have an impact on the mechanical characteristics of the masonry, such as the shear strength. In this paper, an extensive experimental campaign is therefore conducted on masonry triplets to investigate the initial shear strength of concrete block and clay brick masonry, including AAC blocks. The impact of the the presence of a polyethylene DPC layer is also studied. Moreover, the position of the DPC membrane is varied, i.e., directly on top of the brick (which is generally not recommended yet common in construction practice) and in the middle of the mortar joint. In total, 138 shear tests were performed according to the EN 1052-3 standard, with low to moderate precompression levels. The test results focus on the differences in friction angle, shear modulus, and friction coefficient. It is concluded that the presence of an AAC block decreases the initial shear strength to a value which is lower than the one assumed by Eurocode 6. Moreover, when adding a DPC membrane, the shear strength is reduced even further to almost zero, in particular when the membrane is not put in the middle of the mortar joint.-
dc.language.isoen-
dc.publisherMDPI-
dc.rightsCopyright: © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).-
dc.subject.otherautoclaved aerated concrete (AAC)-
dc.subject.otherdamp proof course (DPC)-
dc.subject.otherinitial shear strength-
dc.subject.otherEN 1052-3-
dc.titleExperimental Characterization of the Initial Shear Strength of Composite Masonry including AAC Blocks and DPC Layers-
dc.typeJournal Contribution-
dc.identifier.issue22-
dc.identifier.volume13-
local.bibliographicCitation.jcatA1-
local.publisher.placeST ALBAN-ANLAGE 66, CH-4052 BASEL, SWITZERLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr12749-
dc.identifier.doi10.3390/su132212749-
dc.identifier.isi000724797800001-
local.provider.typePdf-
local.uhasselt.uhpubyes-
local.uhasselt.internationalno-
item.validationecoom 2022-
item.accessRightsOpen Access-
item.fullcitationVANHEUKELOM, Martijn; DAS, Rajarshi; DEGEE, Herve & VANDOREN, Bram (2021) Experimental Characterization of the Initial Shear Strength of Composite Masonry including AAC Blocks and DPC Layers. In: Sustainability (Basel), 13 (22) (Art N° 12749).-
item.fulltextWith Fulltext-
item.contributorVANHEUKELOM, Martijn-
item.contributorDAS, Rajarshi-
item.contributorDEGEE, Herve-
item.contributorVANDOREN, Bram-
crisitem.journal.eissn2071-1050-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
sustainability-13-12749.pdfPublished version15.4 MBAdobe PDFView/Open
Show simple item record

WEB OF SCIENCETM
Citations

2
checked on Apr 23, 2024

Page view(s)

46
checked on Aug 23, 2022

Download(s)

16
checked on Aug 23, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.