Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/36259
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGRUWEZ, Henri-
dc.contributor.authorEvens, S.-
dc.contributor.authorDESTEGHE, Lien-
dc.contributor.authorDREESEN, Pauline-
dc.contributor.authorKNAEPEN, Lieselotte-
dc.contributor.authorWOUTERS, Femke-
dc.contributor.authorDAUW, Jeroen-
dc.contributor.authorDEFERM, Sebastien-
dc.contributor.authorSMEETS, Christophe-
dc.contributor.authorPISON, Laurent-
dc.contributor.authorHaemers, P.-
dc.contributor.authorHEIDBUCHEL, Hein-
dc.contributor.authorVANDERVOORT, Pieter-
dc.date.accessioned2021-12-16T19:29:37Z-
dc.date.available2021-12-16T19:29:37Z-
dc.date.issued2021-
dc.date.submitted2021-12-14T19:29:24Z-
dc.identifier.citationEUROPEAN HEART JOURNAL, 42 , p. 319 -319-
dc.identifier.urihttp://hdl.handle.net/1942/36259-
dc.description.abstractBackground: In the awakening era of mobile health, wearables equipped with photoplethysmography (PPG) technology to monitor the heart rate (HR) and rhythm are on the rise. Smartwatches and wristbands enable HR monitoring for consumers at massive scale. Unfortunately, once consumers become patients, physicians are limited by insufficient evidence to support the clinical use of PPG based wearables. Accurate identification of heartbeats is the first step in the interpretation of PPG traces and should be validated. Purpose: To assess the agreement between continuous PPG monitoring using a smartwatch and continuous ECG Holter monitoring in the identification of heartbeats and calculation of the HR. Methods: One hundred patients (≥18 years) without a pacemaker-dependent heart rhythm who were referred to a university hospital and a large tertiary hospital for elective 24-hour ECG Holter monitoring were asked to wear a continuous PPG monitoring smartwatch (i.e. Samsung GWA2 or Empatica E4) simultaneously with the 24-hour Holter monitor. All activities of daily life were allowed. The ECG trace and PPG waveform were synchronised and fragmented in one-minute fragments. The one-minute ECG fragments were labelled as AF, non-AF, or insufficient quality based on the routine clinical interpretation (i.e. software + physician overread-ing), and the average HR during each fragment was calculated by Holter algorithm. The PPG fragments were analysed by an artificial intelligence (AI) algorithm (i.e. FibriCheck) that labelled fragments as sufficient or in-
dc.description.sponsorshipResearch Foundation-Flanders, Strategic Basic Research Fund-
dc.language.isoen-
dc.publisherOXFORD UNIV PRESS-
dc.titleAssessment of heart rate agreement on continuous photoplethysmography monitoring using a smartwatch versus beat-to-beat synchronized ECG monitoring-
dc.typeJournal Contribution-
dc.identifier.epage319-
dc.identifier.spage319-
dc.identifier.volume42-
local.format.pages1-
local.bibliographicCitation.jcatM-
local.publisher.placeGREAT CLARENDON ST, OXFORD OX2 6DP, ENGLAND-
local.type.refereedRefereed-
local.type.specifiedMeeting Abstract-
dc.identifier.isiWOS:000720456900274-
local.provider.typewosris-
local.uhasselt.uhpubyes-
local.description.affiliation[Gruwez, H.; Haemers, P.] Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium.-
local.description.affiliation[Evens, S.] Qompium NV, Hasselt, Belgium.-
local.description.affiliation[Desteghe, L.; Knaepen, L.; Heidbuchel, H.] Univ Hosp Antwerp, Cardiol, Antwerp, Belgium.-
local.description.affiliation[Dreesen, P.; Wouters, F.] Hasselt Univ, Fac Med & Life Sci, Hasselt, Belgium.-
local.description.affiliation[Dauw, J.; Deferm, S.; Pison, L.; Vandervoort, P.] Hosp Oost Limburg ZOL, Dept Cardiol, Genk, Belgium.-
local.description.affiliation[Smeets, C.] Hosp Oost Limburg ZOL, Future Hlth Dept, Genk, Belgium.-
local.uhasselt.internationalno-
item.fulltextWith Fulltext-
item.contributorGRUWEZ, Henri-
item.contributorEvens, S.-
item.contributorDESTEGHE, Lien-
item.contributorDREESEN, Pauline-
item.contributorKNAEPEN, Lieselotte-
item.contributorWOUTERS, Femke-
item.contributorDAUW, Jeroen-
item.contributorDEFERM, Sebastien-
item.contributorSMEETS, Christophe-
item.contributorPISON, Laurent-
item.contributorHaemers, P.-
item.contributorHEIDBUCHEL, Hein-
item.contributorVANDERVOORT, Pieter-
item.accessRightsRestricted Access-
item.fullcitationGRUWEZ, Henri; Evens, S.; DESTEGHE, Lien; DREESEN, Pauline; KNAEPEN, Lieselotte; WOUTERS, Femke; DAUW, Jeroen; DEFERM, Sebastien; SMEETS, Christophe; PISON, Laurent; Haemers, P.; HEIDBUCHEL, Hein & VANDERVOORT, Pieter (2021) Assessment of heart rate agreement on continuous photoplethysmography monitoring using a smartwatch versus beat-to-beat synchronized ECG monitoring. In: EUROPEAN HEART JOURNAL, 42 , p. 319 -319.-
crisitem.journal.issn0195-668X-
crisitem.journal.eissn1522-9645-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
ehab724.0319.pdf
  Restricted Access
Published version305.36 kBAdobe PDFView/Open    Request a copy
Show simple item record

WEB OF SCIENCETM
Citations

2
checked on Apr 24, 2024

Page view(s)

50
checked on Jul 20, 2022

Download(s)

8
checked on Jul 20, 2022

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.