Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/36331
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVan Berkel, Brecht-
dc.contributor.authorSmets, Gwendolien-
dc.contributor.authorVan Schelverghem, Gertjan-
dc.contributor.authorHouben, Elien-
dc.contributor.authorPeuskens, Dieter-
dc.contributor.authorDaenekindt, Thomas-
dc.contributor.authorBuelens, Evelene-
dc.contributor.authorWEYNS, Frank-
dc.contributor.authorNens, Joris-
dc.contributor.authorHOUBEN, Albrecht-
dc.contributor.authorVAN CAUTER, Sofie-
dc.date.accessioned2021-12-22T15:40:47Z-
dc.date.available2021-12-22T15:40:47Z-
dc.date.issued2021-
dc.date.submitted2021-12-19T21:53:33Z-
dc.identifier.citationAPPLIED SCIENCES-BASEL, 11 (21) , (Art N° 10326)-
dc.identifier.urihttp://hdl.handle.net/1942/36331-
dc.description.abstractNavigation systems used during minimally invasive spine procedures have evolved from uniplanar, two-dimensional C-arm fluoroscopy to multiplanar, 3D intraoperative computed tomography (iCT). In this study, the radiation exposure to the patient and operating room staff in posterior intervertebral lumbar fusion procedures is compared between iCT and C-arm fluoroscopy. The effective dose of the surgeon, operating nurse, and anesthesiologist was measured during surgery with personal dosimeters, and the effective dose of the patient was measured with Gafchromic(TM) films. The time efficiency of the procedure was evaluated by recording the duration of pedicle screw fixation and the duration of the total surgery time. A total of 75 patients participated in the study; 30 patients had surgery guided by iCT and 45 by C-arm fluoroscopy. The radiation dose of the surgeon, the operating nurse, and the anesthesiologist was thirteen fold lower with surgeries assisted by iCT compared to C-arm fluoroscopy. In contrast, the effective dose of the patient significantly increased with iCT. Using iCT, radiation exposure of the operating room staff can be significantly reduced. iCT increases the effective dose of the patient and prolongs the operative time.-
dc.language.isoen-
dc.publisherMDPI-
dc.rights© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).-
dc.subject.otherintraoperative computed tomography; radiation; posterior lumbar fusion-
dc.titleComparison of Radiation Exposure of AIRO Intraoperative CT with C-Arm Fluoroscopy during Posterior Lumbar Interbody Fusion-
dc.typeJournal Contribution-
dc.identifier.issue21-
dc.identifier.volume11-
local.format.pages12-
local.bibliographicCitation.jcatA1-
dc.description.notesVan Berkel, B; Van Cauter, S (corresponding author), Ziekenhuis Oost Limburg, Dept Med Imaging, B-3600 Genk, Belgium.; Van Berkel, B; Van Cauter, S (corresponding author), Univ Hosp Leuven, Dept Radiol, B-3000 Leuven, Belgium.; Van Cauter, S (corresponding author), Univ Hasselt, Fac Med, B-3500 Hasselt, Belgium.-
dc.description.notesbrecht.vanberkel@student.kuleuven.be; gwendoliensmets@outlook.com;-
dc.description.notesgertjanvs@hotmail.com; eliennshouben@gmail.com; dieter.peuskens@zol.be;-
dc.description.notesThomas.Daenekindt@zol.be; eveleen.buelens@zol.be; frank.weyns@zol.be;-
dc.description.notesjoris.nens@zol.be; albrecht.houben@zol.be; sofie.vancauter@zol.be-
local.publisher.placeST ALBAN-ANLAGE 66, CH-4052 BASEL, SWITZERLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr10326-
dc.identifier.doi10.3390/app112110326-
dc.identifier.isiWOS:000726942300001-
local.provider.typewosris-
local.uhasselt.uhpubyes-
local.description.affiliation[Van Berkel, Brecht; Nens, Joris; Houben, Albrecht; Van Cauter, Sofie] Ziekenhuis Oost Limburg, Dept Med Imaging, B-3600 Genk, Belgium.-
local.description.affiliation[Van Berkel, Brecht; Van Cauter, Sofie] Univ Hosp Leuven, Dept Radiol, B-3000 Leuven, Belgium.-
local.description.affiliation[Smets, Gwendolien; Van Schelverghem, Gertjan; Houben, Elien; Weyns, Frank; Van Cauter, Sofie] Univ Hasselt, Fac Med, B-3500 Hasselt, Belgium.-
local.description.affiliation[Peuskens, Dieter; Daenekindt, Thomas; Buelens, Eveleen; Weyns, Frank] Ziekenhuis Oost Limburg, Dept Neurosurg, B-3600 Genk, Belgium.-
local.uhasselt.internationalno-
item.validationecoom 2022-
item.accessRightsOpen Access-
item.fullcitationVan Berkel, Brecht; Smets, Gwendolien; Van Schelverghem, Gertjan; Houben, Elien; Peuskens, Dieter; Daenekindt, Thomas; Buelens, Evelene; WEYNS, Frank; Nens, Joris; HOUBEN, Albrecht & VAN CAUTER, Sofie (2021) Comparison of Radiation Exposure of AIRO Intraoperative CT with C-Arm Fluoroscopy during Posterior Lumbar Interbody Fusion. In: APPLIED SCIENCES-BASEL, 11 (21) , (Art N° 10326).-
item.fulltextWith Fulltext-
item.contributorVan Berkel, Brecht-
item.contributorSmets, Gwendolien-
item.contributorVan Schelverghem, Gertjan-
item.contributorHouben, Elien-
item.contributorPeuskens, Dieter-
item.contributorDaenekindt, Thomas-
item.contributorBuelens, Evelene-
item.contributorWEYNS, Frank-
item.contributorNens, Joris-
item.contributorHOUBEN, Albrecht-
item.contributorVAN CAUTER, Sofie-
crisitem.journal.eissn2076-3417-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
applsci-11-10326.pdfPublished version1.95 MBAdobe PDFView/Open
Show simple item record

WEB OF SCIENCETM
Citations

1
checked on Apr 22, 2024

Page view(s)

46
checked on Jul 20, 2022

Download(s)

4
checked on Jul 20, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.