Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/36467
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | OUDEBROUCKX, Gilles | - |
dc.contributor.author | GOOSSENS, Juul | - |
dc.contributor.author | BORMANS, Seppe | - |
dc.contributor.author | VANDENRYT, Thijs | - |
dc.contributor.author | WAGNER, Patrick | - |
dc.contributor.author | THOELEN, Ronald | - |
dc.date.accessioned | 2022-01-11T14:55:31Z | - |
dc.date.available | 2022-01-11T14:55:31Z | - |
dc.date.issued | 2022 | - |
dc.date.submitted | 2022-01-07T07:29:20Z | - |
dc.identifier.citation | ACS Applied Materials & Interfaces, 14 (2), p. 2440-2451 | - |
dc.identifier.issn | 1944-8244 | - |
dc.identifier.uri | http://hdl.handle.net/1942/36467 | - |
dc.description.abstract | Microplates have become a standard tool in the pharmaceutical industry and academia for a broad range of screening assays. One of the most commonly performed assays is the cell proliferation assay, which is often used for the purpose of drug discovery. Microplate readers play a crucial role in this field, as they enable high-throughput testing of large sample numbers. Common drawbacks of the most popular plate reader technologies are that they are end-point-based and most often require the use of detection reagents. As a solution, with this work, we aim to expand the possibilities of real-time and label-free monitoring of cell proliferation inside a microplate format by introducing a novel thermal-based sensing approach. For this purpose, we have developed thin-film sensors that can easily be integrated into the bottom of standard 96-well plates. First, the accuracy and precision of the sensors for measuring temperature and thermal effusivity are assessed via characterization experiments. These experiments highlight the fast response of the sensors to changes in temperature and thermal effusivity, as well as the excellent reproducibility between different sensors. Later, proof-of-principle measurements were performed on the proliferation of Saccharomyces cerevisiae. The proliferation measurements show that the thermal sensors were able to simultaneously detect relative changes in cell number as well as changes in metabolic activity. This dual functionality makes the presented sensor technology a promising candidate for monitoring microplate assays. | - |
dc.description.sponsorship | The authors kindly acknowledge support for this work by the Research Foundation Flanders FWO within Project G.0791.16.N. Furthermore, this work is funded by the BIOMAT project, which is carried out under Interreg VA Grensregio VlaanderenNederland and is supported by the European Union and The European Regional Development Fund and with the financial support of the Province of Limburg, Belgium. We thank Daniel Nieder for the initial preliminary experiments and Senne Seneca for stimulating discussions. Thanks are extended to Makerspace PXL/ UHasselt for the technical support. | - |
dc.language.iso | en | - |
dc.publisher | AMER CHEMICAL SOC | - |
dc.rights | 2022 American Chemical Society | - |
dc.subject.other | thermal sensor | - |
dc.subject.other | microplate reader | - |
dc.subject.other | cell proliferation | - |
dc.subject.other | cell number | - |
dc.subject.other | metabolic activity | - |
dc.title | Integrating Thermal Sensors in a Microplate Format: Simultaneous Real-Time Quantification of Cell Number and Metabolic Activity | - |
dc.type | Journal Contribution | - |
dc.identifier.epage | 2451 | - |
dc.identifier.issue | 2 | - |
dc.identifier.spage | 2440 | - |
dc.identifier.volume | 14 | - |
local.format.pages | 12 | - |
local.bibliographicCitation.jcat | A1 | - |
local.publisher.place | 1155 16TH ST, NW, WASHINGTON, DC 20036 USA | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
dc.identifier.doi | 10.1021/acsami.1c14668 | - |
dc.identifier.pmid | 34990545 | - |
dc.identifier.isi | 000742325200001 | - |
dc.identifier.eissn | - | |
local.provider.type | CrossRef | - |
local.uhasselt.uhpub | yes | - |
local.uhasselt.international | no | - |
item.validation | ecoom 2023 | - |
item.contributor | OUDEBROUCKX, Gilles | - |
item.contributor | GOOSSENS, Juul | - |
item.contributor | BORMANS, Seppe | - |
item.contributor | VANDENRYT, Thijs | - |
item.contributor | WAGNER, Patrick | - |
item.contributor | THOELEN, Ronald | - |
item.fullcitation | OUDEBROUCKX, Gilles; GOOSSENS, Juul; BORMANS, Seppe; VANDENRYT, Thijs; WAGNER, Patrick & THOELEN, Ronald (2022) Integrating Thermal Sensors in a Microplate Format: Simultaneous Real-Time Quantification of Cell Number and Metabolic Activity. In: ACS Applied Materials & Interfaces, 14 (2), p. 2440-2451. | - |
item.fulltext | With Fulltext | - |
item.accessRights | Open Access | - |
crisitem.journal.issn | 1944-8244 | - |
crisitem.journal.eissn | 1944-8252 | - |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
acsami.1c14668.pdf Restricted Access | Published version | 3.3 MB | Adobe PDF | View/Open Request a copy |
achemso_manuscript_thermal_well_sensors.pdf | Peer-reviewed author version | 7.87 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.