Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/37198
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSarkozy, Andrea-
dc.contributor.authorVIJGEN, Johan-
dc.contributor.authorDe Potter, Tom-
dc.contributor.authorSchilling, Richard-
dc.contributor.authorMarkides, Vias-
dc.date.accessioned2022-04-13T13:11:27Z-
dc.date.available2022-04-13T13:11:27Z-
dc.date.issued2022-
dc.date.submitted2022-04-07T11:39:06Z-
dc.identifier.citationJOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY,-
dc.identifier.urihttp://hdl.handle.net/1942/37198-
dc.description.abstractPurpose We aimed to assess the feasibility, safety, and operator feedback of a novel star-shaped high-density mapping catheter containing 48 platinum-iridium mapping electrodes distributed across eight spines. Methods This prospective, single-arm, first-in-human study was conducted at five European sites. Primary endpoints were completion of pre-ablation mapping requirements, obtaining clinically indicated mapping with the new catheter without resorting to non-study mapping catheters, and incidence of serious adverse events (SAEs). Physician feedback survey assessed catheter performance, including deployment, ease of use, and mapping results. The subjects were followed for 7 days post-procedure. Results Of 31 patients enrolled (11 ventricular tachycardia [VT], 10 scar-related atrial tachycardia [AT]/atypical atrial flutter [AFL], and 10 persistent atrial fibrillation [PsAF]), 28 had study catheter inserted for mapping purposes. Pre-ablation mapping was achieved in 23/28 patients (82.1%). Median of total pre-ablation mapping times were 121.0, 72.5, and 31.5 min for the VT, scar-related AT/atypical AFL, and PsAF subgroups, respectively. More than two-thirds of mapping points acquired were used to generate CARTO maps relevant for ablation. All 16 patients who had conduction channel(s), gaps(s), or critical isthmus identified had the areas successfully mapped. The ability to deploy, maneuver, and reach the atria and ventricles using the catheter was rated positively for most procedures. Only one SAE (heart failure) was reported, unrelated to the device. Conclusion The study results demonstrate the feasibility of the OCTARAY catheter to successfully map complex arrhythmias with good safety profile. Operator feedback indicates satisfaction with ease of use and maneuverability of the catheter.-
dc.description.sponsorshipBiosense Webster, Inc.-
dc.language.isoen-
dc.publisherSPRINGER-
dc.rights© The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2022-
dc.subject.otherAdvanced mapping; Catheters; Electrodes; Atrial fibrillation; Atrial-
dc.subject.othertachycardia; Ventricular tachycardia-
dc.titleAn early multicenter experience of the novel high-density star-shaped mapping catheter in complex arrhythmias-
dc.typeJournal Contribution-
local.format.pages10-
local.bibliographicCitation.jcatA1-
dc.description.notesSarkozy, A (corresponding author), Univ Hosp Antwerp, Dept Cardiol, Wilrijkstr 10, B-2650 Edegem, Belgium.; Sarkozy, A (corresponding author), Univ Antwerp, Prinsstr 13, B-2000 Antwerp, Belgium.-
dc.description.notesAndrea.Sarkozy@uza.be-
local.publisher.placeVAN GODEWIJCKSTRAAT 30, 3311 GZ DORDRECHT, NETHERLANDS-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.statusEarly view-
dc.identifier.doi10.1007/s10840-022-01176-2-
dc.identifier.isiWOS:000773840200001-
local.provider.typewosris-
local.description.affiliation[Sarkozy, Andrea] Univ Hosp Antwerp, Dept Cardiol, Wilrijkstr 10, B-2650 Edegem, Belgium.-
local.description.affiliation[Sarkozy, Andrea] Univ Antwerp, Prinsstr 13, B-2000 Antwerp, Belgium.-
local.description.affiliation[Vijgen, Johan] Jessa Ziekenhuis, Campus Virga Jesse,Stadsomvaart 11, B-3500 Hasselt, Belgium.-
local.description.affiliation[De Potter, Tom] Onze Lieve Vrouw Hosp, Cardiol Dept, Moorselbaan 164, B-9300 Aalst, Belgium.-
local.description.affiliation[Schilling, Richard] St Bartholomews Hosp, London EC1A 7BE, England.-
local.description.affiliation[Markides, Vias] Royal Brompton Hosp, Sydney St, London SW3 6NP, England.-
local.uhasselt.internationalyes-
item.contributorSarkozy, Andrea-
item.contributorVIJGEN, Johan-
item.contributorDe Potter, Tom-
item.contributorSchilling, Richard-
item.contributorMarkides, Vias-
item.fulltextWith Fulltext-
item.fullcitationSarkozy, Andrea; VIJGEN, Johan; De Potter, Tom; Schilling, Richard & Markides, Vias (2022) An early multicenter experience of the novel high-density star-shaped mapping catheter in complex arrhythmias. In: JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY,.-
item.accessRightsRestricted Access-
crisitem.journal.issn1383-875X-
crisitem.journal.eissn1572-8595-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
s10840-022-01176-2.pdf
  Restricted Access
Published version1.92 MBAdobe PDFView/Open    Request a copy
Show simple item record

WEB OF SCIENCETM
Citations

3
checked on Apr 30, 2024

Page view(s)

22
checked on Jun 15, 2022

Download(s)

2
checked on Jun 15, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.