Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/37353
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWOUTERS, Femke-
dc.contributor.authorGRUWEZ, Henri-
dc.contributor.authorVRANKEN, Julie-
dc.contributor.authorErnon, Ludovic-
dc.contributor.authorMESOTTEN, Dieter-
dc.contributor.authorVANDERVOORT, Pieter-
dc.contributor.authorVERHAERT, David-
dc.date.accessioned2022-05-30T13:47:47Z-
dc.date.available2022-05-30T13:47:47Z-
dc.date.issued2022-
dc.date.submitted2022-05-10T12:46:01Z-
dc.identifier.citationFRONTIERS IN CARDIOVASCULAR MEDICINE, 9 (Art N° 839853)-
dc.identifier.issn2297-055X-
dc.identifier.urihttp://hdl.handle.net/1942/37353-
dc.description.abstractBackground and CaseThis case report exemplifies the clinical application of non-invasive photoplethysmography (PPG)-based rhythm monitoring in the awakening mobile health (mHealth) era to detect symptomatic and asymptomatic paroxysmal atrial fibrillation (AF) in a cryptogenic stroke patient. Despite extensive diagnostic workup, the etiology remains unknown in one out of three ischemic strokes (i.e., cryptogenic stroke). Prolonged cardiac monitoring can reveal asymptomatic atrial fibrillation in up to one-third of this population. This case report describes a cryptogenic stroke patient who received prolonged cardiac monitoring with an insertable cardiac monitor (ICM) as standard of care. In the context of a clinical study, the patient simultaneously monitored his heart rhythm with a PPG-based smartphone application. AF was detected simultaneously on both the ICM and smartphone application after three days of monitoring. Similar AF burden was detected during follow-up (five episodes, median duration of 28 and 34 h on ICM and mHealth, respectively, p = 0.5). The detection prompted the initiation of oral anticoagulation and AF catheter ablation procedure. ConclusionThis is the first report of the cryptogenic stroke patient in whom PPG-based mHealth was able to detect occurrence and burden of the symptomatic and asymptomatic paroxysmal AF episodes with similar precision as ICM. It accentuates the potential role of PPG-based mHealth in prolonged cardiac rhythm monitoring in cryptogenic stroke patients.-
dc.description.sponsorshipThis study was supported by the Bijzonder Onderzoeksfonds (BOF) of Hasselt University (BOF20DOC17). This study is part of Limburg Clinical Research Center, supported by the foundation Limburg Sterk Merk, province of Limburg, Flemish government, Hasselt University, Ziekenhuis OostLimburg and Jessa Hospital-
dc.language.isoen-
dc.publisherFRONTIERS MEDIA SA-
dc.rights2022 Wouters, Gruwez, Vranken, Ernon, Mesotten, Vandervoort and Verhaert. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.-
dc.subject.otheratrial fibrillation-
dc.subject.othercryptogenic stroke-
dc.subject.othermobile health-
dc.subject.othercase report-
dc.subject.otherinsertable cardiac monitor (ICM)-
dc.titleWill Smartphone Applications Replace the Insertable Cardiac Monitor in the Detection of Atrial Fibrillation? The First Comparison in a Case Report of a Cryptogenic Stroke Patient-
dc.typeJournal Contribution-
dc.identifier.spage839853-
dc.identifier.volume9-
local.format.pages6-
local.bibliographicCitation.jcatA1-
dc.description.notesWouters, F (corresponding author), Hasselt Univ, Fac Med & Life Sci, Limburg Clin Res Ctr, Mobile Hlth Unit, Hasselt, Belgium.; Wouters, F (corresponding author), Ziekenhuis Oost Limburg, Dept Future Hlth, Genk, Belgium.-
dc.description.notesfemke.wouters@uhasselt.be-
local.publisher.placeAVENUE DU TRIBUNAL FEDERAL 34, LAUSANNE, CH-1015, SWITZERLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr839853-
dc.identifier.doi10.3389/fcvm.2022.839853-
dc.identifier.pmid35402567-
dc.identifier.isiWOS:000780912500001-
dc.contributor.orcidWouters, Femke/0000-0002-4420-6372-
dc.identifier.eissn2297-055X-
local.provider.typewosris-
local.description.affiliation[Wouters, Femke; Gruwez, Henri; Vranken, Julie; Mesotten, Dieter; Vandervoort, Pieter] Hasselt Univ, Fac Med & Life Sci, Limburg Clin Res Ctr, Mobile Hlth Unit, Hasselt, Belgium.-
local.description.affiliation[Wouters, Femke; Gruwez, Henri; Vranken, Julie; Vandervoort, Pieter] Ziekenhuis Oost Limburg, Dept Future Hlth, Genk, Belgium.-
local.description.affiliation[Gruwez, Henri; Vandervoort, Pieter; Verhaert, David] Ziekenhuis Oost Limburg, Dept Cardiol, Genk, Belgium.-
local.description.affiliation[Gruwez, Henri] Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium.-
local.description.affiliation[Ernon, Ludovic] Ziekenhuis Oost Limburg, Dept Neurol, Genk, Belgium.-
local.description.affiliation[Mesotten, Dieter] Ziekenhuis Oost Limburg, Dept Anesthesiol, Genk, Belgium.-
local.uhasselt.internationalno-
item.validationecoom 2023-
item.fulltextWith Fulltext-
item.accessRightsOpen Access-
item.fullcitationWOUTERS, Femke; GRUWEZ, Henri; VRANKEN, Julie; Ernon, Ludovic; MESOTTEN, Dieter; VANDERVOORT, Pieter & VERHAERT, David (2022) Will Smartphone Applications Replace the Insertable Cardiac Monitor in the Detection of Atrial Fibrillation? The First Comparison in a Case Report of a Cryptogenic Stroke Patient. In: FRONTIERS IN CARDIOVASCULAR MEDICINE, 9 (Art N° 839853).-
item.contributorWOUTERS, Femke-
item.contributorGRUWEZ, Henri-
item.contributorVRANKEN, Julie-
item.contributorErnon, Ludovic-
item.contributorMESOTTEN, Dieter-
item.contributorVANDERVOORT, Pieter-
item.contributorVERHAERT, David-
crisitem.journal.issn2297-055X-
crisitem.journal.eissn2297-055X-
Appears in Collections:Research publications
Show simple item record

WEB OF SCIENCETM
Citations

1
checked on Apr 30, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.