Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/37940
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGHEKIERE, Olivier-
dc.contributor.authorDacher, Jean-Nicolas-
dc.contributor.authorDewilde , Willem-
dc.contributor.authorCOOLS, Wilfried-
dc.contributor.authorDENDALE, Paul-
dc.contributor.authorNchimi, Alain-
dc.date.accessioned2022-09-01T07:19:39Z-
dc.date.available2022-09-01T07:19:39Z-
dc.date.issued2022-
dc.date.submitted2022-08-16T12:38:11Z-
dc.identifier.citationJournal of the Belgian Society of Radiology, 106 (1) (Art N° 59)-
dc.identifier.urihttp://hdl.handle.net/1942/37940-
dc.description.abstractBackground: To evaluate the diagnostic accuracy of semi-quantitative adenosine perfusion magnetic resonance imaging (MRI) to determine fractional flow reserve (FFR) <= 0.80 intermediate-grade coronary stenoses as compared to visual analysis. Methods: Forty-six patients (mean age 61 +/- 9 years; 33 males) with 49 intermediate-grade stenoses (59 +/- 7.6%; range, 42-70% minimal diameter reduction) underwent adenosine perfusion MRI and FFR measurement within four months in this retrospective study. MRI was visually assessed by two experienced readers twice with one-year interval, the second time with the knowledge of the diseased artery. The stress subendocardial myocardial enhancement maximal upslope was evaluated distal to the coronary stenosis (=RISK) and divided by the same value in remote myocardium supplied by normal arteries (=REMOTE) to obtain the relative myocardial perfusion index (RMPI). Results: The average FFR value was 0.84 +/- 0.09 and 15/49(31%) intermediate-grade stenoses were FFR <= 0.80. The kappa-values for interobserver agreement assessing inducible perfusion defects on visual readings was 0.20 on the first reading and increased to 0.62 with the knowledge of the stenosis location. Consensus readings had a diagnostic accuracy of 82%(40/49) in identifying FFR <= 0.80 stenoses on both blinded and unblinded readings with regards to the knowledge of the stenosis location. Meanwhile, stress subendocardial RMPI had higher accuracy (43/49[88%]) than visual readings to predict FFR <= 0.80 stenoses, using a cutoff value of 0.84. Conclusion: By assessing perfusion changes in remote myocardium, semi-quantitative MRI analysis using stress subendocardial RMPI can provide an equal or more accurate alternative to visual analysis in identifying FFR <= 0.80 intermediate-grade stenoses. Larger cohorts of patients are required to validate this approach.-
dc.description.sponsorshipThe authors gratefully acknowledge Isabelle Mancini and Dr. Julien Djekic of the radiology department and Dr. Michel Bellekens of the cardiology department at CHC Hospital, Liège, and Dr. Tim Coolen of the radiology department at University Hospital Erasme, Brussels for their assistance in acquiring the data. This work has received funding by by General Electrics Healthcare. The funding has been used to cover the costs of the adenosine perfusion MR, the contrast medium and adenosine of all included patients. Funding for the statistical analysis was received by Limburg Clinical Research Center (LCRC) Hasselt University, Hospital Oost-Limburg and Jessa Hospital.-
dc.language.isoen-
dc.publisherUBIQUITY PRESS LTD-
dc.rights2022 The Author(s). This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC-BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. See http://creativecommons.org/licenses/by/4.0/.-
dc.subject.otherCoronary artery stenosis-
dc.subject.otherperfusion magnetic resonance imaging-
dc.subject.otheradenosine-
dc.subject.otherfractional flow reserve-
dc.subject.othersemi-quantitative analysis-
dc.titleSemi-Quantitative Versus Visual Analysis of Adenosine Perfusion Magnetic Resonance Imaging in Intermediate-Grade Coronary Artery Stenosis Using Fractional Flow Reserve as the Reference: A Pilot Study-
dc.typeJournal Contribution-
dc.identifier.issue1-
dc.identifier.volume106-
local.bibliographicCitation.jcatA1-
dc.description.notesGhekiere, O (corresponding author), Jessa Ziekenhuis, Dept Radiol, Stadsomvaart 11, B-3500 Hasselt, Belgium.-
dc.description.notesolivier.ghekiere@jessazh.be-
local.publisher.placeUnit 3.22, East London Works, 65-75 Whitechapel Road, LONDON, E1 1DU, ENGLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr59-
dc.identifier.doi10.5334/jbsr.2675-
dc.identifier.pmid35814277-
dc.identifier.isi000819272400002-
local.provider.typewosris-
local.description.affiliation[Ghekiere, Olivier] Jessa Ziekenhuis, Dept Radiol, Stadsomvaart 11, B-3500 Hasselt, Belgium.-
local.description.affiliation[Ghekiere, Olivier] Ctr Hosp Chretien CHC, Dept Radiol, Rue Hesbaye 75, B-4000 Liege, Belgium.-
local.description.affiliation[Ghekiere, Olivier; Dendale, Paul] Hasselt Univ, Fac Med & Life Sci, Biomed & Reval, Agoralaan,Bldg A&C, B-3500 Hasselt, Belgium.-
local.description.affiliation[Dacher, Jean-Nicolas] Normandie UNIV, CHU Rouen, Dept Radiol, Inserm U1096,UNIROUEN, F-76000 Rouen, France.-
local.description.affiliation[Dewilde, Willem] Imelda Hosp, Dept Cardiol, Imeldalaan 9, B-2820 Bonheiden, Belgium.-
local.description.affiliation[Cools, Wilfired] Vrje Univ Brussel VUB, Interfac Ctr Data Proc & Stat, Pl Str 2, B-1050 Brussels, Belgium.-
local.description.affiliation[Dendale, Paul] Jessa Ziekenhuis, Heart Ctr Hasselt, Stadsomvaart 11, B-3500 Hasselt, Belgium.-
local.description.affiliation[Nchimi, Alain] Ctr Hosp Luxembourg, 4 Rue Ernest Barble, L-1120 Luxembourg, Luxembourg.-
local.uhasselt.internationalyes-
item.validationecoom 2023-
item.contributorGHEKIERE, Olivier-
item.contributorDacher, Jean-Nicolas-
item.contributorDewilde , Willem-
item.contributorCOOLS, Wilfried-
item.contributorDENDALE, Paul-
item.contributorNchimi, Alain-
item.accessRightsOpen Access-
item.fullcitationGHEKIERE, Olivier; Dacher, Jean-Nicolas; Dewilde , Willem; COOLS, Wilfried; DENDALE, Paul & Nchimi, Alain (2022) Semi-Quantitative Versus Visual Analysis of Adenosine Perfusion Magnetic Resonance Imaging in Intermediate-Grade Coronary Artery Stenosis Using Fractional Flow Reserve as the Reference: A Pilot Study. In: Journal of the Belgian Society of Radiology, 106 (1) (Art N° 59).-
item.fulltextWith Fulltext-
crisitem.journal.issn2514-8281-
crisitem.journal.eissn2514-8281-
Appears in Collections:Research publications
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.