dc.description.abstractPurposeThis study aimed to investigate Doppler characteristics of maternal internal jugular veins in uncomplicated pregnancies vs. those affected by hypertensive disorders. Materials and methodsVenous pulse transit time and venous impedance index were measured at three different locations (right proximal, right distal, left proximal) of internal jugular veins according to a standardised combined Doppler-Electrocardiogram protocol in five different groups of pregnant women: uncomplicated pregnancy, early-onset preeclampsia, late-onset preeclampsia, gestational hypertension, and normotensive pregnancies with a small for gestational age foetus. Values of both parameters of the latter four groups were plotted against the reference range of uncomplicated pregnancies at corresponding gestation. Linear mixed models with random intercept were used to investigate gestational changes in venous pulse transit time and venous impedance index at the three internal jugular vein locations within and between the different groups. ResultsA total of 127 women were included: 41 had uncomplicated pregnancies, 13 had early-onset preeclampsia, 25 had late-onset preeclampsia, 22 had gestational hypertension, and 26 had normotensive pregnancies with a small for gestational age foetus. Venous pulse transit time values were lower than uncomplicated pregnancy (p <= 0.001) at all three locations in the third trimester of early-onset preeclampsia. ConclusionContrary to late-onset preeclampsia and gestational hypertension, early-onset preeclampsia is characterised by a lower venous pulse transit time at internal jugular veins compared to uncomplicated pregnancy, suggesting increased venous vascular tone.-
dc.language.isoen-
dc.publisherFRONTIERS MEDIA SA-
dc.rights© 2022 Dierickx, Kremer, Bruckers and Gyselaers. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.-
dc.subject.othercombined Doppler-Electrocardiogram-
dc.subject.othervenous pulse transit time-
dc.subject.othervenous impedance index-
dc.subject.otherpreeclampsia-
dc.subject.othergestational hypertension-
dc.subject.othervenous maternal haemodynamics-
dc.subject.othereclampsia-
dc.subject.otherinternal jugular vein-
dc.titleEarly-onset preeclampsia is characterised by an increased vascular tone in internal jugular veins-
dc.typeJournal Contribution-
dc.identifier.volume9-
local.bibliographicCitation.jcatA1-
dc.description.notesDierickx, I (corresponding author), Sint Lucas Ziekenhuis, Dept Obstet & Gynaecol, Ghent, Belgium.; Dierickx, I (corresponding author), Hasselt Univ, Dept Physiol, Hasselt, Belgium.-
dc.description.notesinge.dierickx@azstlucas.be-
local.publisher.placeAVENUE DU TRIBUNAL FEDERAL 34, LAUSANNE, CH-1015, SWITZERLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr911059-
dc.identifier.doi10.3389/fcvm.2022.911059-
dc.identifier.pmid36035962-
dc.identifier.isi000844884500001-
local.provider.typewosris-
local.description.affiliation[Dierickx, Inge] Sint Lucas Ziekenhuis, Dept Obstet & Gynaecol, Ghent, Belgium.-
local.description.affiliation[Dierickx, Inge; Gyselaers, Wilfried] Hasselt Univ, Dept Physiol, Hasselt, Belgium.-
local.description.affiliation[Kremer, Cecile; Bruckers, Liesbeth] Hasselt Univ, Interuniv Inst Biostat & Stat Bioinformat, Hasselt, Belgium.-
local.description.affiliation[Gyselaers, Wilfried] East Limburg Hosp, Dept Obstet & Gynaecol, Genk, Belgium.-
local.uhasselt.internationalno-
item.fulltextWith Fulltext-
item.accessRightsOpen Access-
item.validationecoom 2023-
item.contributorDIERICKX, Inge-
item.contributorKREMER, Cécile-
item.contributorBRUCKERS, Liesbeth-
item.contributorGYSELAERS, Wilfried-
item.fullcitationDIERICKX, Inge; KREMER, Cécile; BRUCKERS, Liesbeth & GYSELAERS, Wilfried (2022) Early-onset preeclampsia is characterised by an increased vascular tone in internal jugular veins. In: Frontiers in Cardiovascular Medicine, 9 (Art N° 911059).-
crisitem.journal.issn2297-055X-
crisitem.journal.eissn2297-055X-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Early-onset preeclampsia is characterised by an increased vascular tone in internal jugular veins.pdfPublished version430.79 kBAdobe PDFView/Open
Show simple item record

WEB OF SCIENCETM
Citations

1
checked on May 8, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.