dc.description.abstractAn automated potentiometric determination of the oxygen content of the superconductor YBCO is described. The end-point of the titration is found using a linear Gran plot technique. Suitable equations are derived by which the number of titration points can be considerably reduced and the titration can be stopped even before the equivalence point is reached. Automation of the iodimetric titration can be performed in an easy manner. During the titration a good estimate of the equivalence volume can be calculated using only two titration points.-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.subject.otherPOTENTIOMETRY; TITRIMETRY; COPPER; GRAN PLOTS; IODIMETRY; SUPERCONDUCTORS; YBCO SUPERCONDUCTOR-
dc.titleAUTOMATED IODIMETRIC DETERMINATION OF CU+, CU-2+ AND CU-3+ IN THE SUPERCONDUCTOR YBCO USING A MODIFIED GRAN PLOT TECHNIQUE-
dc.typeJournal Contribution-
dc.identifier.epage519-
dc.identifier.issue1-2-
dc.identifier.spage511-
dc.identifier.volume273-
local.format.pages9-
dc.description.notesYPERMAN, J, LIMBURG STATE UNIV CTR,INORGAN & PHYS CHEM LAB,B-3590 DIEPENBEEK,BELGIUM.-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.bibliographicCitation.oldjcatA1-
dc.identifier.isiA1993KM93400060-
item.fullcitationYPERMAN, Jan; DE BACKER, An; VOS, A; FRANCO, Dirk; MULLENS, Jules & VAN POUCKE, Lucien (1993) AUTOMATED IODIMETRIC DETERMINATION OF CU+, CU-2+ AND CU-3+ IN THE SUPERCONDUCTOR YBCO USING A MODIFIED GRAN PLOT TECHNIQUE. In: ANALYTICA CHIMICA ACTA, 273(1-2). p. 511-519.-
item.fulltextNo Fulltext-
item.contributorYPERMAN, Jan-
item.contributorDE BACKER, An-
item.contributorVOS, A-
item.contributorFRANCO, Dirk-
item.contributorMULLENS, Jules-
item.contributorVAN POUCKE, Lucien-
item.accessRightsClosed Access-
Appears in Collections:Research publications
Show simple item record

WEB OF SCIENCETM
Citations

10
checked on May 2, 2024

Page view(s)

62
checked on Sep 6, 2022

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.