Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/39006
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVanreusel, Verdi-
dc.contributor.authorGasparini, Alessia-
dc.contributor.authorGalante, Federica-
dc.contributor.authorMariani, Giulia-
dc.contributor.authorPacitti, Matteo-
dc.contributor.authorCociorb, Madalina-
dc.contributor.authorGiammanco, Andrea-
dc.contributor.authorRENIERS, Brigitte-
dc.contributor.authorREULENS, Nathalie-
dc.contributor.authorShonde, Tunde Blessed-
dc.contributor.authorVallet, Hugo-
dc.contributor.authorVandenbroucke, Dirk-
dc.contributor.authorPeeters , Marc-
dc.contributor.authorLeblans, Paul-
dc.contributor.authorMa, Biwu-
dc.contributor.authorFelici, Giuseppe-
dc.contributor.authorVerellen, Dirk-
dc.contributor.authorNascimento, Luana de Freitas-
dc.date.accessioned2022-12-06T09:05:25Z-
dc.date.available2022-12-06T09:05:25Z-
dc.date.issued2022-
dc.date.submitted2022-12-01T13:22:21Z-
dc.identifier.citationPhysica Medica-European Journal of Medical Physics, 103 , p. 127 -137-
dc.identifier.urihttp://hdl.handle.net/1942/39006-
dc.description.abstractFLASH radiation therapy is a novel technique combining ultra-high dose rates (UHDR) with very short treatment times to strongly decrease normal tissue toxicity while preserving the anti-tumoral effect. However, the radiobiological mechanisms and exact conditions for obtaining the FLASH-effect are still under investigation. There are strong indications that parameters defining the beam structure, such as dose per pulse, instantaneous dose rate and pulse repetition frequency (PRF) are of importance. UHDR irradiations therefore come with dosimetric challenges, including both dose assessment and temporal ones. In this work, a first characterization of 6 real-time point scintillating dosimeters with 5 phosphors (Al2O3:C,Mg; Y2O3:Eu; Al2O3:C; (C38H34P2)MnBr4 and (C38H34P2)MnCl4, was performed in an UHDR pulsed electron beam. The dose rate independence of the calibration was tested by calibrating the detector at conventional and UHDR. Dose rate dependence was observed, however, further investigation, including intermediate dose rates, is needed. Linearity of the response with dose was tested by varying the number of pulses and a linearity with R-2 > 0.9989 was observed up to at least 200 Gy. Dose per pulse linearity was investigated by variation of the pulse length and SSD. All point scintillators showed saturation effects up to some extent and the instantaneous dose rate dependence was confirmed. A PRF dependence was observed for the Al2O3:C,Mg and Al2O3:C- based point scintillators. This was expected as the luminescence decay time of these materials exceeds the inter-pulse time.-
dc.description.sponsorshipThis work was supported by VLAIO via the Flanders.HealthTech call [HBC.2021.0946]. SCK CEN and Iridium Network are also non-funded collaborators to the 18HLT04 UHDpulse project which received funding from the EMPIR programme. UHDR research in the Iridium Network is partially funded by Sordina IORT Technologies S.p.A.. TBS and BM thank the support from the FSU GAP Commercialization Investment Program.-
dc.language.isoen-
dc.publisherELSEVIER SCI LTD-
dc.rights2022 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights reserved-
dc.subject.otherFLASH-RT-
dc.subject.otherReal-time dosimetry-
dc.subject.otherRadioluminescence-
dc.subject.otherPoint scintillators-
dc.titlePoint scintillator dosimetry in ultra-high dose rate electron "FLASH" radiation therapy: A first characterization-
dc.typeJournal Contribution-
dc.identifier.epage137-
dc.identifier.spage127-
dc.identifier.volume103-
local.format.pages11-
local.bibliographicCitation.jcatA1-
dc.description.notesVanreusel, V (corresponding author), SCK CEN, Res Dosimetr Applicat, Mol, Belgium.; Vanreusel, V (corresponding author), Univ Antwerp, CORE, Antwerp, Belgium.; Vanreusel, V (corresponding author), Iridium Netwerk, Antwerp, Belgium.-
dc.description.notesverdi.vanreusel@sckcen.be-
local.publisher.placeTHE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, OXON, ENGLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1016/j.ejmp.2022.10.005-
dc.identifier.pmid36302279-
dc.identifier.isi000880766300002-
dc.contributor.orcidVanreusel, Verdi/0000-0001-7287-133X; Gasparini,-
dc.contributor.orcidAlessia/0000-0001-5078-5131-
local.provider.typewosris-
local.description.affiliation[Vanreusel, Verdi; Nascimento, Luana de Freitas] SCK CEN, Res Dosimetr Applicat, Mol, Belgium.-
local.description.affiliation[Vanreusel, Verdi; Gasparini, Alessia; Vallet, Hugo; Verellen, Dirk] Univ Antwerp, CORE, Antwerp, Belgium.-
local.description.affiliation[Vanreusel, Verdi; Gasparini, Alessia; Verellen, Dirk] Iridium Netwerk, Antwerp, Belgium.-
local.description.affiliation[Galante, Federica; Mariani, Giulia; Pacitti, Matteo; Felici, Giuseppe] Sordina IORT Technol SpA, Latina, Italy.-
local.description.affiliation[Cociorb, Madalina; Giammanco, Andrea] DoseVue NV, Diepenbeek, Belgium.-
local.description.affiliation[Reniers, Brigitte; Reulens, Nathalie] Hasselt Univ, CMK, NuTeC, Hasselt, Belgium.-
local.description.affiliation[Shonde, Tunde Blessed; Ma, Biwu] Florida State Univ, Dept Chem & Biochem, Tallahassee, FL USA.-
local.description.affiliation[Leblans, Paul] Agfa NV, Mortsel, Belgium.-
local.description.affiliation[Peeters, Marc] UZA, Edegem, Belgium.-
local.uhasselt.internationalyes-
item.validationecoom 2023-
item.fullcitationVanreusel, Verdi; Gasparini, Alessia; Galante, Federica; Mariani, Giulia; Pacitti, Matteo; Cociorb, Madalina; Giammanco, Andrea; RENIERS, Brigitte; REULENS, Nathalie; Shonde, Tunde Blessed; Vallet, Hugo; Vandenbroucke, Dirk; Peeters , Marc; Leblans, Paul; Ma, Biwu; Felici, Giuseppe; Verellen, Dirk & Nascimento, Luana de Freitas (2022) Point scintillator dosimetry in ultra-high dose rate electron "FLASH" radiation therapy: A first characterization. In: Physica Medica-European Journal of Medical Physics, 103 , p. 127 -137.-
item.contributorVanreusel, Verdi-
item.contributorGasparini, Alessia-
item.contributorGalante, Federica-
item.contributorMariani, Giulia-
item.contributorPacitti, Matteo-
item.contributorCociorb, Madalina-
item.contributorGiammanco, Andrea-
item.contributorRENIERS, Brigitte-
item.contributorREULENS, Nathalie-
item.contributorShonde, Tunde Blessed-
item.contributorVallet, Hugo-
item.contributorVandenbroucke, Dirk-
item.contributorPeeters , Marc-
item.contributorLeblans, Paul-
item.contributorMa, Biwu-
item.contributorFelici, Giuseppe-
item.contributorVerellen, Dirk-
item.contributorNascimento, Luana de Freitas-
item.accessRightsRestricted Access-
item.fulltextWith Fulltext-
crisitem.journal.issn1120-1797-
crisitem.journal.eissn1724-191X-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Point scintillator dosimetry in ultra-high dose rate electron “FLASH” radiation therapy_ A first characterization.pdf
  Restricted Access
Published version2.45 MBAdobe PDFView/Open    Request a copy
Show simple item record

WEB OF SCIENCETM
Citations

7
checked on May 8, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.