Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/40035
Full metadata record
DC FieldValueLanguage
dc.contributor.authorvan den Buijs, Deborah M. F.-
dc.contributor.authorPoels, Ella M.-
dc.contributor.authorFerdinande, Bert-
dc.contributor.authorCottens, Daan-
dc.contributor.authorVROLIX, Mathias-
dc.contributor.authorDAUW, Jeroen-
dc.contributor.authorDENS, Jo-
dc.contributor.authorAMELOOT, Koen-
dc.date.accessioned2023-05-08T13:55:15Z-
dc.date.available2023-05-08T13:55:15Z-
dc.date.issued2023-
dc.date.submitted2023-05-05T10:38:58Z-
dc.identifier.citationMedical science monitor, 29 , p. e939429 (Art N° e939429)-
dc.identifier.urihttp://hdl.handle.net/1942/40035-
dc.description.abstractBackground: During transradial coronary angiography, when conventional J-tip wires fail to deliver catheters to the aortic root due to anatomical obstacles, additional hydrophilic wires, such as Radifocus (Terumo) or Silverway (Asahi), are used. We recently showed that the Silverway guidewire was effective at delivering the catheter to the aortic root. In this study, we aimed to compare the efficacy and safety of Radifocus and Silverway guidewires in 100 patients after failed use of the J-tip guidewire. Material/Methods: After patients had a failure of a conventional J-tip wire to reach the aortic root, 100 patients were 1:1 randomized to either the Silverway or Radifocus wire. All patients with failure of the J-tip wire were eligible. The primary endpoint was the time between wire entry in the catheter and successful delivery of the catheter to the aortic root. Secondary endpoints included change of access site, number of complications, and questionnaires on subjective wire assessments by the performing interventional cardiologist. Results: The primary endpoint was significantly shorter in patients randomized to the Silverway arm (median 30 s [21-39] vs 48 s [36-66]; P<0.001)). The percentage of patients with change of access site was not different between the groups (2 vs 2, not significant). Only 1 minor complication (2%) occurred, in the Radifocus group. Questionnaires revealed that torque control, crossing, and support were all significantly better with the Silverway wire (P<0.001). Conclusions: Silverway showed superior torque control, resulting in faster catheter delivery to the aortic root when compared with the Radifocus guidewire.-
dc.language.isoen-
dc.publisherINT SCIENTIFIC INFORMATION, INC-
dc.rightsThis work is licensed under Creative Common AttributionNonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)-
dc.subject.otherCardiac Catheterization-
dc.subject.otherCardiac Catheterization-
dc.subject.otherCardiac Catheters-
dc.subject.otherCardiac Catheters-
dc.subject.otherCoronary Angiography-
dc.subject.otherCoronary Angiography-
dc.subject.otherRadial Artery Full-text PDF: https-
dc.subject.otherRadial Artery-
dc.titleComparison of Radifocus versus Silverway Guidewires for Percutaneous Radial Angiography Following Failed Use of a J-Tip Guidewire-
dc.typeJournal Contribution-
dc.identifier.spagee939429-
dc.identifier.volume29-
local.format.pages6-
local.bibliographicCitation.jcatA1-
dc.description.notesvan den Buijs, DMF; Poels, EM (corresponding author), Ziekenhuis Oost Limburg, Dept Cardiol, Genk, Limburg, Belgium.-
dc.description.notesd.vandenbuijs@gmail.com-
local.publisher.place150 BROADHOLLOW RD, STE 114, MELVILLE, NY 11747 USA-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnre939429-
dc.identifier.doi10.12659/MSM.939429-
dc.identifier.pmid37025045-
dc.identifier.isi000972040900001-
dc.contributor.orcidvan den Buijs, Deborah/0000-0002-1613-5829-
local.provider.typewosris-
local.description.affiliation[van den Buijs, Deborah M. F.; Poels, Ella M.; Ferdinande, Bert; Cottens, Daan; Vrolix, Mathias; Dauw, Jeroen; Dens, Jo; Ameloot, Koen] Ziekenhuis Oost Limburg, Dept Cardiol, Genk, Limburg, Belgium.-
local.description.affiliation[Dens, Jo; Ameloot, Koen] Univ Hasselt, Fac Med & Life Sci, Diepenbeek, Belgium.-
local.uhasselt.internationalno-
item.fullcitationvan den Buijs, Deborah M. F.; Poels, Ella M.; Ferdinande, Bert; Cottens, Daan; VROLIX, Mathias; DAUW, Jeroen; DENS, Jo & AMELOOT, Koen (2023) Comparison of Radifocus versus Silverway Guidewires for Percutaneous Radial Angiography Following Failed Use of a J-Tip Guidewire. In: Medical science monitor, 29 , p. e939429 (Art N° e939429).-
item.contributorvan den Buijs, Deborah M. F.-
item.contributorPoels, Ella M.-
item.contributorFerdinande, Bert-
item.contributorCottens, Daan-
item.contributorVROLIX, Mathias-
item.contributorDAUW, Jeroen-
item.contributorDENS, Jo-
item.contributorAMELOOT, Koen-
item.accessRightsOpen Access-
item.fulltextWith Fulltext-
crisitem.journal.issn1234-1010-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
939429.pdfPublished version2.5 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.