Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/40560
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ghafari, Chadi | - |
dc.contributor.author | Houissa, Khalil | - |
dc.contributor.author | DENS, Jo | - |
dc.contributor.author | Ungureanu, Claudiu | - |
dc.contributor.author | Kayaert, Peter | - |
dc.contributor.author | Constant, Cyril | - |
dc.contributor.author | Carlier, Stephane | - |
dc.date.accessioned | 2023-07-12T08:48:15Z | - |
dc.date.available | 2023-07-12T08:48:15Z | - |
dc.date.issued | 2023 | - |
dc.date.submitted | 2023-07-06T13:57:39Z | - |
dc.identifier.citation | Algorithms, 16 (6) (Art N° 276) | - |
dc.identifier.uri | http://hdl.handle.net/1942/40560 | - |
dc.description.abstract | (1) Background: Stent underexpansion is the main cause of stent thrombosis and restenosis. Coronary angiography has limitations in the assessment of stent expansion. Enhanced stent imaging (ESI) methods allow a detailed visualization of stent deployment. We qualitatively compare image results from two ESI system vendors (StentBoost & TRADE; (SB) and CAAS StentEnhancer & TRADE; (SE)) and report quantitative results of deployed stents diameters by quantitative coronary angiography (QCA) and by SE. (2) Methods: The ESI systems from SB and SE were compared and graded by two blinded observers for different characteristics: 1 visualization of the proximal and distal edges of the stents; 2 visualization of the stent struts; 3 presence of underexpansion and 4 calcifications. Stent diameters were quantitatively measured using dedicated QCA and SE software and compared to chart diameters according to the pressure of implantation. (3) Results: A total of 249 ESI sequences were qualitatively compared. Inter-observer variability was noted for strut visibility and total scores. Inter-observer agreement was found for the assessment of proximal stent edge and stent underexpansion. The predicted chart diameters were 0.31 & PLUSMN; 0.30 mm larger than SE diameters (p < 0.05). Stent diameters by SE after post-dilatation were 0.47 & PLUSMN; 0.31 mm smaller than the post-dilation balloon diameter (p < 0.05). SE-derived diameters significantly differed from QCA; by Bland-Altman analysis the bias was -0.37 & PLUSMN; 0.42 mm (p < 0.001). (4) Conclusions: SE provides an enhanced visualization and allows precise quantitative assessment of stent expansion without the limitations of QCA when overlapping coronary side branches are present. | - |
dc.language.iso | en | - |
dc.publisher | MDPI | - |
dc.rights | 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/). | - |
dc.subject.other | stent | - |
dc.subject.other | percutaneous coronary intervention | - |
dc.subject.other | quantitative coronary angiography | - |
dc.title | Clinical Validation of a New Enhanced Stent Imaging Method | - |
dc.type | Journal Contribution | - |
dc.identifier.issue | 6 | - |
dc.identifier.volume | 16 | - |
local.bibliographicCitation.jcat | A1 | - |
dc.description.notes | Carlier, S (corresponding author), Univ Mons UMONS, Dept Cardiol, B-7000 Mons, Belgium.; Carlier, S (corresponding author), CHU Ambroise Pare, Cardiol Dept, B-7000 Mons, Belgium. | - |
dc.description.notes | chadi.ghafari@umons.ac.be; khalilhouissa@gmail.com; jo.dens@zol.be; | - |
dc.description.notes | claudiu-mih.ungureanu@jolimont.be; peter.kayaert@jessazh.be; | - |
dc.description.notes | cyril.constant@ulb.ac.be; stephane.carlier@umons.ac.be | - |
local.publisher.place | ST ALBAN-ANLAGE 66, CH-4052 BASEL, SWITZERLAND | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
local.bibliographicCitation.artnr | 276 | - |
dc.identifier.doi | 10.3390/a16060276 | - |
dc.identifier.isi | 001013888200001 | - |
local.provider.type | wosris | - |
local.description.affiliation | [Ghafari, Chadi; Ungureanu, Claudiu; Carlier, Stephane] Univ Mons UMONS, Dept Cardiol, B-7000 Mons, Belgium. | - |
local.description.affiliation | [Houissa, Khalil] Mil Hosp Tunis, Dept Cardiol, Tunis 1000, Tunisia. | - |
local.description.affiliation | [Dens, Jo] Ziekenhuis Oost Limburg, Cardiol Dept, B-3600 Genk, Belgium. | - |
local.description.affiliation | [Ungureanu, Claudiu] Hop Jolimont, Cardiol Dept, B-7100 La Louviere, Belgium. | - |
local.description.affiliation | [Kayaert, Peter] Jessa Ziekenhuis, Cardiol Dept, B-3500 Hasselt, Belgium. | - |
local.description.affiliation | [Constant, Cyril] Free Univ Brussels ULB, Fac Med, B-1050 Brussels, Belgium. | - |
local.description.affiliation | [Carlier, Stephane] CHU Ambroise Pare, Cardiol Dept, B-7000 Mons, Belgium. | - |
local.uhasselt.international | yes | - |
item.fullcitation | Ghafari, Chadi; Houissa, Khalil; DENS, Jo; Ungureanu, Claudiu; Kayaert, Peter; Constant, Cyril & Carlier, Stephane (2023) Clinical Validation of a New Enhanced Stent Imaging Method. In: Algorithms, 16 (6) (Art N° 276). | - |
item.contributor | Ghafari, Chadi | - |
item.contributor | Houissa, Khalil | - |
item.contributor | DENS, Jo | - |
item.contributor | Ungureanu, Claudiu | - |
item.contributor | Kayaert, Peter | - |
item.contributor | Constant, Cyril | - |
item.contributor | Carlier, Stephane | - |
item.accessRights | Open Access | - |
item.fulltext | With Fulltext | - |
crisitem.journal.eissn | 1999-4893 | - |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Clinical Validation of a New Enhanced Stent Imaging Method.pdf | Published version | 2.02 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.