dc.identifier.urihttp://hdl.handle.net/1942/40560-
dc.description.abstract(1) Background: Stent underexpansion is the main cause of stent thrombosis and restenosis. Coronary angiography has limitations in the assessment of stent expansion. Enhanced stent imaging (ESI) methods allow a detailed visualization of stent deployment. We qualitatively compare image results from two ESI system vendors (StentBoost & TRADE; (SB) and CAAS StentEnhancer & TRADE; (SE)) and report quantitative results of deployed stents diameters by quantitative coronary angiography (QCA) and by SE. (2) Methods: The ESI systems from SB and SE were compared and graded by two blinded observers for different characteristics: 1 visualization of the proximal and distal edges of the stents; 2 visualization of the stent struts; 3 presence of underexpansion and 4 calcifications. Stent diameters were quantitatively measured using dedicated QCA and SE software and compared to chart diameters according to the pressure of implantation. (3) Results: A total of 249 ESI sequences were qualitatively compared. Inter-observer variability was noted for strut visibility and total scores. Inter-observer agreement was found for the assessment of proximal stent edge and stent underexpansion. The predicted chart diameters were 0.31 & PLUSMN; 0.30 mm larger than SE diameters (p < 0.05). Stent diameters by SE after post-dilatation were 0.47 & PLUSMN; 0.31 mm smaller than the post-dilation balloon diameter (p < 0.05). SE-derived diameters significantly differed from QCA; by Bland-Altman analysis the bias was -0.37 & PLUSMN; 0.42 mm (p < 0.001). (4) Conclusions: SE provides an enhanced visualization and allows precise quantitative assessment of stent expansion without the limitations of QCA when overlapping coronary side branches are present.-
dc.language.isoen-
dc.publisherMDPI-
dc.rights2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).-
dc.subject.otherstent-
dc.subject.otherpercutaneous coronary intervention-
dc.subject.otherquantitative coronary angiography-
dc.titleClinical Validation of a New Enhanced Stent Imaging Method-
dc.typeJournal Contribution-
dc.identifier.issue6-
dc.identifier.volume16-
local.bibliographicCitation.jcatA1-
dc.description.notesCarlier, S (corresponding author), Univ Mons UMONS, Dept Cardiol, B-7000 Mons, Belgium.; Carlier, S (corresponding author), CHU Ambroise Pare, Cardiol Dept, B-7000 Mons, Belgium.-
dc.description.noteschadi.ghafari@umons.ac.be; khalilhouissa@gmail.com; jo.dens@zol.be;-
dc.description.notesclaudiu-mih.ungureanu@jolimont.be; peter.kayaert@jessazh.be;-
dc.description.notescyril.constant@ulb.ac.be; stephane.carlier@umons.ac.be-
local.publisher.placeST ALBAN-ANLAGE 66, CH-4052 BASEL, SWITZERLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr276-
dc.identifier.doi10.3390/a16060276-
dc.identifier.isi001013888200001-
local.provider.typewosris-
local.description.affiliation[Ghafari, Chadi; Ungureanu, Claudiu; Carlier, Stephane] Univ Mons UMONS, Dept Cardiol, B-7000 Mons, Belgium.-
local.description.affiliation[Houissa, Khalil] Mil Hosp Tunis, Dept Cardiol, Tunis 1000, Tunisia.-
local.description.affiliation[Dens, Jo] Ziekenhuis Oost Limburg, Cardiol Dept, B-3600 Genk, Belgium.-
local.description.affiliation[Ungureanu, Claudiu] Hop Jolimont, Cardiol Dept, B-7100 La Louviere, Belgium.-
local.description.affiliation[Kayaert, Peter] Jessa Ziekenhuis, Cardiol Dept, B-3500 Hasselt, Belgium.-
local.description.affiliation[Constant, Cyril] Free Univ Brussels ULB, Fac Med, B-1050 Brussels, Belgium.-
local.description.affiliation[Carlier, Stephane] CHU Ambroise Pare, Cardiol Dept, B-7000 Mons, Belgium.-
local.uhasselt.internationalyes-
item.fullcitationGhafari, Chadi; Houissa, Khalil; DENS, Jo; Ungureanu, Claudiu; Kayaert, Peter; Constant, Cyril & Carlier, Stephane (2023) Clinical Validation of a New Enhanced Stent Imaging Method. In: Algorithms, 16 (6) (Art N° 276).-
item.contributorGhafari, Chadi-
item.contributorHouissa, Khalil-
item.contributorDENS, Jo-
item.contributorUngureanu, Claudiu-
item.contributorKayaert, Peter-
item.contributorConstant, Cyril-
item.contributorCarlier, Stephane-
item.accessRightsOpen Access-
item.fulltextWith Fulltext-
crisitem.journal.eissn1999-4893-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Clinical Validation of a New Enhanced Stent Imaging Method.pdfPublished version2.02 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.