Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/40819
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | SCHOUTTETEN, Melanie | - |
dc.contributor.author | Lindeboom, Lucas | - |
dc.contributor.author | Brys, Astrid | - |
dc.contributor.author | LANSSENS, Dorien | - |
dc.contributor.author | SMEETS, Christophe | - |
dc.contributor.author | DE CANNIERE, Helene | - |
dc.contributor.author | DE MOOR, Bart | - |
dc.contributor.author | Peeters , Jacques | - |
dc.contributor.author | HEYLEN, Line | - |
dc.contributor.author | Van Hoof, Chris | - |
dc.contributor.author | Groenendaal, Willemijn | - |
dc.contributor.author | Kooman, Jeroen | - |
dc.contributor.author | VANDERVOORT, Pieter | - |
dc.date.accessioned | 2023-09-04T08:43:20Z | - |
dc.date.available | 2023-09-04T08:43:20Z | - |
dc.date.issued | 2023 | - |
dc.date.submitted | 2023-09-04T07:23:35Z | - |
dc.identifier.citation | NEPHROLOGY DIALYSIS TRANSPLANTATION, 38 , p. I844 -I845 | - |
dc.identifier.uri | http://hdl.handle.net/1942/40819 | - |
dc.description.abstract | Background and Aims: In contrast to portable whole-body bioimpedance, which estimates fluid status at a single point in time, thoracic bioimpedance applied by a wearable device could enable continuous measurements. However, clinical experience with thoracic bioimpedance in patients in dialysis is still limited. The aim of this study is to test the reproducibility of whole-body and thoracic bioimpedance measurements and to compare their association with hemodynamic changes during hemodialysis. Method: In total, 54 patients were included in this cross-sectional observational study. Whole-body resistance at 5kHz, thoracic resistance at 8kHz, systolic blood pressure and ultrafiltration volume were measured. All measurements were taken at pre-and end-dialysis during two consecutive sessions. Data were approached by mixed-modelling and Spearman correlation analysis. | - |
dc.language.iso | en | - |
dc.publisher | OXFORD UNIV PRESS | - |
dc.rights | Free access | - |
dc.title | Comparison of whole-body versus thoracic bioimpedance in relation to ultrafiltration volume and systolic blood pressure during hemodialysis | - |
dc.type | Journal Contribution | - |
local.bibliographicCitation.conferencedate | JUN 15-18, 2023 | - |
local.bibliographicCitation.conferencename | 60th ERA Congress | - |
local.bibliographicCitation.conferenceplace | Milan, ITALY | - |
dc.identifier.epage | I845 | - |
dc.identifier.spage | I844 | - |
dc.identifier.volume | 38 | - |
local.format.pages | 2 | - |
local.bibliographicCitation.jcat | M | - |
local.publisher.place | GREAT CLARENDON ST, OXFORD OX2 6DP, ENGLAND | - |
local.type.refereed | Refereed | - |
local.type.specified | Meeting Abstract | - |
dc.identifier.isi | 001022961103033 | - |
local.provider.type | wosris | - |
local.description.affiliation | [Schoutteten, Melanie; Lanssens, Dorien; De Canniere, Helene; De Moor, Bart] Univ Hasselt, Hasselt, Belgium. | - |
local.description.affiliation | [Lindeboom, Lucas; Groenendaal, Willemijn] Imec Netherlands, Eindhoven, Netherlands. | - |
local.description.affiliation | [Brys, Astrid; Kooman, Jeroen] MUMC, Maastricht, Netherlands. | - |
local.description.affiliation | [Smeets, Christophe; Peeters, Jacques; Vandervoort, Pieter] IMEC, Louvain, Belgium. | - |
local.uhasselt.international | yes | - |
item.accessRights | Open Access | - |
item.fulltext | With Fulltext | - |
item.contributor | SCHOUTTETEN, Melanie | - |
item.contributor | Lindeboom, Lucas | - |
item.contributor | Brys, Astrid | - |
item.contributor | LANSSENS, Dorien | - |
item.contributor | SMEETS, Christophe | - |
item.contributor | DE CANNIERE, Helene | - |
item.contributor | DE MOOR, Bart | - |
item.contributor | Peeters , Jacques | - |
item.contributor | HEYLEN, Line | - |
item.contributor | Van Hoof, Chris | - |
item.contributor | Groenendaal, Willemijn | - |
item.contributor | Kooman, Jeroen | - |
item.contributor | VANDERVOORT, Pieter | - |
item.fullcitation | SCHOUTTETEN, Melanie; Lindeboom, Lucas; Brys, Astrid; LANSSENS, Dorien; SMEETS, Christophe; DE CANNIERE, Helene; DE MOOR, Bart; Peeters , Jacques; HEYLEN, Line; Van Hoof, Chris; Groenendaal, Willemijn; Kooman, Jeroen & VANDERVOORT, Pieter (2023) Comparison of whole-body versus thoracic bioimpedance in relation to ultrafiltration volume and systolic blood pressure during hemodialysis. In: NEPHROLOGY DIALYSIS TRANSPLANTATION, 38 , p. I844 -I845. | - |
crisitem.journal.issn | 0931-0509 | - |
crisitem.journal.eissn | 1460-2385 | - |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
#4784IDENTIFICATION OF FACTORS ASSOCIATED WITH DEATH IN DIALYSIS PATIENTS USING A MACHINE LEARNING-BASED PREDICTIVE MODEL.pdf | Published version | 168.03 kB | Adobe PDF | View/Open |
Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.