Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/41500
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVanreusel, Verdi-
dc.contributor.authorGasparini, Alessia-
dc.contributor.authorGalante, Federica-
dc.contributor.authorMariani, Giulia-
dc.contributor.authorPacitti, Matteo-
dc.contributor.authorColijn, Arnaud-
dc.contributor.authorRENIERS, Brigitte-
dc.contributor.authorYALVAC, Burak-
dc.contributor.authorVandenbroucke, Dirk-
dc.contributor.authorPeeters, Marc-
dc.contributor.authorLeblans, Paul-
dc.contributor.authorFelici, Giuseppe-
dc.contributor.authorde Freitas Nascimento, Luana-
dc.contributor.authorVerellen, Dirk-
dc.date.accessioned2023-10-11T09:33:34Z-
dc.date.available2023-10-11T09:33:34Z-
dc.date.issued2023-
dc.date.submitted2023-10-05T12:38:35Z-
dc.identifier.citationPhysica Medica-European Journal of Medical Physics, 114 (Art N° 103147)-
dc.identifier.issn1120-1797-
dc.identifier.urihttp://hdl.handle.net/1942/41500-
dc.description.abstractRadiotherapy is part of the treatment of over 50% of cancer patients. Its efficacy is limited by the radiotoxicity to the healthy tissue. FLASH-RT is based on the biological effect that ultra-high dose rates (UHDR) and very short treatment times strongly reduce normal tissue toxicity, while preserving the anti-tumoral effect. Despite many positive preclinical results, the translation of FLASH-RT to the clinic is hampered by the lack of accurate dosimetry for UHDR beams. To date radiochromic film is commonly used for dose assessment but has the drawback of lengthy and cumbersome read out procedures. In this work, we investigate the equivalence of a 2D OSL system to radiochromic film dosimetry in terms of dose rate independency. The comparison of both systems was done using the ElectronFlash linac. We investigated the dose rate dependence by variation of the (1) modality, (2) pulse repetition frequency, (3) pulse length and (4) source to surface distance. Additionally, we compared the 2D characteristics by field size measurements. The OSL calibration showed transferable between conventional and UHDR modality. Both systems are equally independent of average dose rate, pulse length and instantaneous dose rate. The OSL system showed equivalent in field size determination within 3 sigma. We show the promising nature of the 2D OSL system to serve as alternative for radiochromic film in UHDR electron beams. However, more in depth characterization is needed to assess its full potential.-
dc.description.sponsorshipThis work was supported by VLAIO, Belgium via the Flanders.HealthTech call [HBC.2021.0946]. SCK CEN and Iridium Network are also non-funded collaborators to the 18HLT04 UHDpulse project which received funding from the EMPIR program.-
dc.language.isoen-
dc.publisherELSEVIER SCI LTD-
dc.rights2023 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights reserved.-
dc.subject.otherFLASH-RT-
dc.subject.otherReference dosimetry-
dc.subject.otherOptically stimulated luminescence-
dc.titleOptically stimulated luminescence system as an alternative for radiochromic film for 2D reference dosimetry in UHDR electron beams-
dc.typeJournal Contribution-
dc.identifier.volume114-
local.bibliographicCitation.jcatA1-
dc.description.notesVanreusel, V (corresponding author), Boeretang 200, Mol, Belgium.-
dc.description.notesverdi.vanreusel@sckcen.be-
local.publisher.place125 London Wall, London, ENGLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr103147-
dc.identifier.doi10.1016/j.ejmp.2023.103147-
dc.identifier.pmid37804712-
dc.identifier.isi001148184400001-
dc.identifier.eissn1724-191X-
local.provider.typeCrossRef-
local.description.affiliation[Vanreusel, Verdi; Nascimento, Luana de Freitas] SCK CEN, Res Dosimetr Applicat, Boeretang 200, B-2400 Mol, Belgium.-
local.description.affiliation[Vanreusel, Verdi; Gasparini, Alessia; Galante, Federica; Mariani, Giulia; Pacitti, Matteo; Colijn, Arnaud; Reniers, Brigitte; Yalvac, Burak; Vandenbroucke, Dirk; Peeters, Marc; Leblans, Paul; Felici, Giuseppe; Verellen, Dirk; Nascimento, Luana de Freitas] Univ Antwerp, CORE, Univ Pl 1, B-2610 Antwerp, Belgium.-
local.description.affiliation[Vanreusel, Verdi; Gasparini, Alessia; Verellen, Dirk] Iridium Netwerk, Oosterveldlaan 22, B-2610 Antwerp, Belgium.-
local.description.affiliation[Galante, Federica; Mariani, Giulia; Pacitti, Matteo; Felici, Giuseppe] Sordina IORT Technol SpA, Via Ind 1-A, I-04011 Aprilia, Latina, Italy.-
local.description.affiliation[Reniers, Brigitte; Yalvac, Burak] Hasselt Univ, NuTeC, CMK, Wetenschapspk 27, B-3590 Diepenbeek, Belgium.-
local.description.affiliation[Vandenbroucke, Dirk; Leblans, Paul] Agfa NV, Septestr 27, B-2640 Mortsel, Belgium.-
local.description.affiliation[Peeters, Marc] UZA, Edegem, Belgium.-
local.description.affiliation[Vanreusel, Verdi] Boeretang 200, Mol, Belgium.-
local.uhasselt.internationalyes-
item.fullcitationVanreusel, Verdi; Gasparini, Alessia; Galante, Federica; Mariani, Giulia; Pacitti, Matteo; Colijn, Arnaud; RENIERS, Brigitte; YALVAC, Burak; Vandenbroucke, Dirk; Peeters, Marc; Leblans, Paul; Felici, Giuseppe; de Freitas Nascimento, Luana & Verellen, Dirk (2023) Optically stimulated luminescence system as an alternative for radiochromic film for 2D reference dosimetry in UHDR electron beams. In: Physica Medica-European Journal of Medical Physics, 114 (Art N° 103147).-
item.contributorVanreusel, Verdi-
item.contributorGasparini, Alessia-
item.contributorGalante, Federica-
item.contributorMariani, Giulia-
item.contributorPacitti, Matteo-
item.contributorColijn, Arnaud-
item.contributorRENIERS, Brigitte-
item.contributorYALVAC, Burak-
item.contributorVandenbroucke, Dirk-
item.contributorPeeters, Marc-
item.contributorLeblans, Paul-
item.contributorFelici, Giuseppe-
item.contributorde Freitas Nascimento, Luana-
item.contributorVerellen, Dirk-
item.fulltextWith Fulltext-
item.accessRightsOpen Access-
crisitem.journal.issn1120-1797-
crisitem.journal.eissn1724-191X-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
1-s2.0-S1120179723001746-main.pdfPublished version2.33 MBAdobe PDFView/Open
Show simple item record

WEB OF SCIENCETM
Citations

2
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.