Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/41687
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPinxterhuis, Tineke H.-
dc.contributor.authorPloumen, Eline H.-
dc.contributor.authorZocca, Paolo-
dc.contributor.authorDoggen, Carine J. M.-
dc.contributor.authorSchotborgh, Carl E.-
dc.contributor.authorAnthonio, Rutger L.-
dc.contributor.authorRoguin, Ariel-
dc.contributor.authorDanse, Peter W.-
dc.contributor.authorBENIT, Edouard-
dc.contributor.authorAminian, Adel-
dc.contributor.authorHouwelingen, K. Gert van-
dc.contributor.authorLinssen, Gerard C. M.-
dc.contributor.authorGeelkerken, Robert H.-
dc.contributor.authorvon Birgelen, Clemens-
dc.date.accessioned2023-11-08T09:59:35Z-
dc.date.available2023-11-08T09:59:35Z-
dc.date.issued2023-
dc.date.submitted2023-11-01T12:59:32Z-
dc.identifier.citationCardiovascular Diagnosis and Therapy, 13 (4) , p. 673 -685-
dc.identifier.urihttp://hdl.handle.net/1942/41687-
dc.description.abstractBackground: In patients with peripheral arterial disease (PADs), who underwent percutaneous coronary intervention (PCI), little is known about the potential impact of using different new-generation drug-eluting stents (DES) on outcome. In PCI all-comers, the results of most between-stent comparisons-stratified by strut thickness-suggested some advantage of coronary stents with ultrathin-struts. The current post-hoc analysis aimed to assess outcomes of PCI with ultrathin-strut biodegradable polymer sirolimus-eluting stents (BP-SES) vs. thin-strut durable polymer zotarolimus-eluting stents (DP-ZES) in patients with PADs. Methods: We pooled 3-year patient-level data from two large-scale randomized all-comer trials to compare Orsiro ultrathin-strut BP-SES vs. Resolute-type thin-strut DP-ZES in trial participants with concomitant PADs. BIO-RESORT (December 2012 to August 2015) and BIONYX (October 2015 to December 2016) included all-comer patients who were aged 18 years or older, capable of providing informed consent, and required a PCI. The trials had web-based randomization, with block sizes of 4 and 8, performed in a 1:1:1 or 1:1 fashion. Assessors, research staff, and patients were blinded to the type of stent used. We assessed the composite main clinical endpoint target vessel failure [TVF: cardiac death, target vessel related myocardial infarction (MI), or clinically indicated target vessel revascularization (TVR)], its components, and stent thrombosis.Results: Of 4,830 trial participants, 360 had PADs: 177 (49.2%) were treated with BP-SES and 183 (50.8%) with DP-ZES. Baseline characteristics were similar. For BP-SES, the 3-year TVF rate was 11.0% and for DP-ZES 17.9% [hazard ratio (HR): 0.59, 95% CI: 0.33-1.04; P=0.07]. For BP-SES, the TVR rate was lower than for DP-ZES (4.1% vs. 11.0%; HR: 0.36, 95% CI: 0.15-0.86; P=0.016), but this did not translate into between-group differences in cardiac death or MI. In small vessels (<2.75 mm), the TVR rate was also lower in BP-SES (5.6% vs. 13.9%; HR: 0.32, 95% CI: 0.11-0.91; P=0.024). Definite-or-probable stent thrombosis rates were 1.2% and 2.3% (P=0.43).Conclusions: In PCI patients with PADs, the 3-year TVF incidence was numerically lower in the ultrathin-strut BP-SES vs. the thin-strut DP-ZES group. Furthermore, TVR risk was significantly lower in ultrathin-strut BP-SES, mainly driven by a lower TVR rate in small vessels. Trial Registration: BIO-RESORT trial: clinicaltrials.gov (NCT01674803); BIONYX trial: clinicaltrials.gov (NCT02508714).-
dc.description.sponsorshipFunding: The BIO-RESORT trial was equally funded by Biotronik, Boston Scientific, and Medtronic. The BIONYX trial was equally funded by Biotronik, and Medtronic. Funders of the original randomized clinical trials had no impact on the design, conduct, analysis, and reporting of the present study. There was no external funding for performing the present study.-
dc.language.isoen-
dc.publisherAME PUBLISHING COMPANY-
dc.rightsCardiovascular Diagnosis and Therapy. All rights reserved. Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the noncommercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0/.-
dc.subject.otherCoronary artery disease-
dc.subject.otherperipheral arterial disease (PADs)-
dc.subject.otherpercutaneous coronary intervention (PCI)-
dc.subject.otherdrug-eluting stent-
dc.subject.otherrandomized trial-
dc.titleOutcome of percutaneous coronary intervention using ultrathin- strut biodegradable polymer sirolimus-eluting versus thin-strut durable polymer zotarolimus-eluting stents in patients with comorbid peripheral arterial disease: a post-hoc analysis from two randomized trials-
dc.typeJournal Contribution-
dc.identifier.epage685-
dc.identifier.issue4-
dc.identifier.spage673-
dc.identifier.volume13-
local.format.pages15-
local.bibliographicCitation.jcatA1-
dc.description.notesvon Birgelen, C (corresponding author), Univ Twente, Fac BMS, Tech Med Ctr, Hlth Technol & Serv Res, Enschede, Netherlands.; von Birgelen, C (corresponding author), Thoraxctr Twente, Cardiol Dept A25, Med Spectrum Twente MST, Koningspl 1, NL-7512 EZ Enschede, Netherlands.-
dc.description.notesc.vonbirgelen@mst.nl-
local.publisher.placeFLAT-RM C 16F, KINGS WING PLAZA 1, NO 3 KWAN ST, SHATIN, HONG KONG 00000, PEOPLES R CHINA-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.21037/cdt-22-584-
dc.identifier.pmid37675090-
dc.identifier.isi001039480900001-
local.provider.typewosris-
local.description.affiliation[Pinxterhuis, Tineke H.; Ploumen, Eline H.; Zocca, Paolo; Houwelingen, K. Gert van; von Birgelen, Clemens] Thoraxctr Twente, Med Spectrum Twente, Dept Cardiol, Enschede, Netherlands.-
local.description.affiliation[Pinxterhuis, Tineke H.; Ploumen, Eline H.; Doggen, Carine J. M.; von Birgelen, Clemens] Univ Twente, Fac BMS, Tech Med Ctr, Hlth Technol & Serv Res, Enschede, Netherlands.-
local.description.affiliation[Schotborgh, Carl E.] Haga Hosp, Dept Cardiol, The Hague, Netherlands.-
local.description.affiliation[Anthonio, Rutger L.] Scheper Hosp, Dept Cardiol, Treant Zorggrp, Emmen, Netherlands.-
local.description.affiliation[Roguin, Ariel] Israel Inst Technol, Hadera & B Rappaport Fac Med, Hillel Yaffe Med Ctr, Dept Cardiol, Haifa, Israel.-
local.description.affiliation[Danse, Peter W.] Rijnstate Hosp, Dept Cardiol, Arnhem, Netherlands.-
local.description.affiliation[Benit, Edouard] Jessa Hosp, Dept Cardiol, Hasselt, Belgium.-
local.description.affiliation[Aminian, Adel; Linssen, Gerard C. M.] Ctr Hosp Univ Charleroi, Dept Cardiol, Charleroi, Belgium.-
local.description.affiliation[Linssen, Gerard C. M.] Ziekenhuisgrp Twente, Dept Cardiol, Almelo, Netherlands.-
local.description.affiliation[Geelkerken, Robert H.] Med Spectrum Twente, Dept Vasc Surg, Enschede, Netherlands.-
local.description.affiliation[Geelkerken, Robert H.] Univ Twente, Fac Sci & Technol, Tech Med Ctr, Multimodal Med Imaging Grp M3I, Enschede, Netherlands.-
local.description.affiliation[von Birgelen, Clemens] Thoraxctr Twente, Cardiol Dept A25, Med Spectrum Twente MST, Koningspl 1, NL-7512 EZ Enschede, Netherlands.-
local.uhasselt.internationalyes-
item.fulltextWith Fulltext-
item.fullcitationPinxterhuis, Tineke H.; Ploumen, Eline H.; Zocca, Paolo; Doggen, Carine J. M.; Schotborgh, Carl E.; Anthonio, Rutger L.; Roguin, Ariel; Danse, Peter W.; BENIT, Edouard; Aminian, Adel; Houwelingen, K. Gert van; Linssen, Gerard C. M.; Geelkerken, Robert H. & von Birgelen, Clemens (2023) Outcome of percutaneous coronary intervention using ultrathin- strut biodegradable polymer sirolimus-eluting versus thin-strut durable polymer zotarolimus-eluting stents in patients with comorbid peripheral arterial disease: a post-hoc analysis from two randomized trials. In: Cardiovascular Diagnosis and Therapy, 13 (4) , p. 673 -685.-
item.accessRightsOpen Access-
item.contributorPinxterhuis, Tineke H.-
item.contributorPloumen, Eline H.-
item.contributorZocca, Paolo-
item.contributorDoggen, Carine J. M.-
item.contributorSchotborgh, Carl E.-
item.contributorAnthonio, Rutger L.-
item.contributorRoguin, Ariel-
item.contributorDanse, Peter W.-
item.contributorBENIT, Edouard-
item.contributorAminian, Adel-
item.contributorHouwelingen, K. Gert van-
item.contributorLinssen, Gerard C. M.-
item.contributorGeelkerken, Robert H.-
item.contributorvon Birgelen, Clemens-
crisitem.journal.issn2223-3652-
crisitem.journal.eissn2223-3660-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
115897-PB7-5703-R2.pdfPublished version327.98 kBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.