Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/41984
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVan Slambrouck, Jan-
dc.contributor.authorSchoenaers, Charlotte-
dc.contributor.authorLaenen , Lies-
dc.contributor.authorJin, Xin-
dc.contributor.authorBeuselinck, Kurt-
dc.contributor.authorVerdonck, Ann-
dc.contributor.authorWauters, Joost-
dc.contributor.authorMOLENBERGHS, Geert-
dc.contributor.authorVanaudenaerde, Bart M.-
dc.contributor.authorVOS, Robin-
dc.contributor.authorMombaerts, Peter-
dc.contributor.authorLagrou, Katrien-
dc.contributor.authorCeulemans, Laurens J.-
dc.date.accessioned2024-01-03T11:05:07Z-
dc.date.available2024-01-03T11:05:07Z-
dc.date.issued2024-
dc.date.submitted2024-01-03T09:49:43Z-
dc.identifier.citationJOURNAL OF VIROLOGICAL METHODS, 323 (Art N° 114848)-
dc.identifier.urihttp://hdl.handle.net/1942/41984-
dc.description.abstractBackground: Transmission of SARS-CoV-2 from donor to recipient is a clinically relevant risk for developing severe COVID-19 after lung transplantation (LTx). This risk of iatrogenic transmission can be reduced by timely detection of viral RNA or antigen in samples of bronchoalveolar lavage (BAL) fluid obtained at the time of lung procurement. We aimed to retrospectively evaluate the detection of SARS-CoV-2 RNA or antigen in BAL fluid samples using three point-of-care tests (POCTs).Methods: BAL fluid samples came from patients hospitalized in an intensive care unit during the COVID-19 pandemic. These pandemic samples were scored as positive or negative for SARS-CoV-2 by a RT-qPCR comparator assay for orf1ab. Three commercially available POCTs were then evaluated: cobas SARS-CoV-2 & Influenza A/B assay with the cobas Liat RT-qPCR system (Roche Diagnostics), ID NOW COVID-19 and COVID-19 2.0 (Abbott), and SARS-CoV-2 Rapid Antigen Test (RAT) (Roche Diagnostics). Samples from the pre-pandemic era served as negative controls.Results: We analyzed a total of 98 BAL fluid samples, each from a different patient: 58 positive pandemic samples (orf1ab Ct<38), 20 putatively negative pandemic samples (orf1ab Ct >= 38), and 20 pre-pandemic samples. Uni-variate logistic regression shows that the probability of detection was highest for cobas Liat, followed by ID NOW, and then RAT. Of clinical relevance, cobas Liat detected SARS-CoV-2 RNA in 30 of the 31 positive pandemic samples that were collected within 10 days after RT-qPCR diagnosis of SARS-CoV-2 infection. None of the 20 pre-pandemic samples had a false-positive result for any POCT.Conclusions: POCTs enable the detection of SARS-CoV-2 RNA or antigen in BAL fluid samples and may provide additional information to decide if donor lungs are suitable for transplantation. Detection of respiratory pathogens with POCTs at the time of donor lung procurement is a potential strategy to increase safety in LTx by preventing iatrogenic transmission and severe postoperative infections.-
dc.description.sponsorshipFund Academic Research (KOOR) of University Hospitals Leuven. The authors thank Nicole Jannis (KU Leuven, Belgium) and Yo Vande Broeck (University Hospitals Leuven, Belgium) for their help with collecting and processing of samples.-
dc.language.isoen-
dc.publisherELSEVIER-
dc.rights2023 Elsevier B.V. All rights reserved.-
dc.subject.otherBronchoalveolar lavage-
dc.subject.otherCOVID-19-
dc.subject.otherLung transplantation-
dc.subject.otherPoint -of -care test-
dc.subject.otherSARS-CoV-2-
dc.titleThe value of point-of-care tests for the detection of SARS-CoV-2 RNA or antigen in bronchoalveolar lavage fluid-
dc.typeJournal Contribution-
dc.identifier.volume323-
local.format.pages5-
local.bibliographicCitation.jcatA1-
dc.description.notesCeulemans, LJ (corresponding author), Univ Hosp Leuven, Dept Thorac Surg, Herestr 49, B-3000 Leuven, Belgium.-
dc.description.noteslaurens.ceulemans@uzleuven.be-
local.publisher.placeRADARWEG 29, 1043 NX AMSTERDAM, NETHERLANDS-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr114848-
dc.identifier.doi10.1016/j.jviromet.2023.114848-
dc.identifier.pmid37944670-
dc.identifier.isi001113496700001-
dc.contributor.orcidVos, MD, PhD, Robin/0000-0002-3468-9251; Van Slambrouck,-
dc.contributor.orcidJan/0000-0002-7069-1535; Ceulemans, Laurens/0000-0002-4261-7100;-
dc.contributor.orcidVanaudenaerde, Bart/0000-0001-6435-6901-
local.provider.typewosris-
local.description.affiliation[Van Slambrouck, Jan; Schoenaers, Charlotte; Jin, Xin; Vanaudenaerde, Bart M.; Ceulemans, Laurens J.] Katholieke Univ Leuven, Dept Chron Dis & Metab, Lab Resp Dis & Thorac Surg BREATHE, Leuven, Belgium.-
local.description.affiliation[Van Slambrouck, Jan; Schoenaers, Charlotte; Vos, Robin; Ceulemans, Laurens J.] Univ Hosp Leuven, Dept Thorac Surg, Herestr 49, B-3000 Leuven, Belgium.-
local.description.affiliation[Laenen, Lies; Beuselinck, Kurt; Verdonck, Ann; Lagrou, Katrien] Univ Hosp Leuven, Dept Lab Med, Leuven, Belgium.-
local.description.affiliation[Laenen, Lies; Beuselinck, Kurt; Verdonck, Ann; Lagrou, Katrien] Univ Hosp Leuven, Natl Reference Ctr Resp Pathogens, Leuven, Belgium.-
local.description.affiliation[Wauters, Joost] Katholieke Univ Leuven, Dept Microbiol Immunol & Transplantat, Leuven, Belgium.-
local.description.affiliation[Wauters, Joost] Univ Hosp Leuven, Med Intens Care Unit, Leuven, Belgium.-
local.description.affiliation[Molenberghs, Geert] Katholieke Univ Leuven, Interuniv Inst Biostat & Stat Bioinformat, Leuven, Belgium.-
local.description.affiliation[Molenberghs, Geert] UHasselt, Leuven, Belgium.-
local.description.affiliation[Vos, Robin] Univ Hosp Leuven, Dept Resp Dis, Leuven, Belgium.-
local.description.affiliation[Mombaerts, Peter] Max Planck Res Unit Neurogenet, Frankfurt, Germany.-
local.description.affiliation[Lagrou, Katrien] Katholieke Univ Leuven, Dept Microbiol Immunol & Transplantat, Lab Clin Microbiol, Leuven, Belgium.-
local.uhasselt.internationalyes-
item.fulltextWith Fulltext-
item.accessRightsEmbargoed Access-
item.contributorVan Slambrouck, Jan-
item.contributorSchoenaers, Charlotte-
item.contributorLaenen , Lies-
item.contributorJin, Xin-
item.contributorBeuselinck, Kurt-
item.contributorVerdonck, Ann-
item.contributorWauters, Joost-
item.contributorMOLENBERGHS, Geert-
item.contributorVanaudenaerde, Bart M.-
item.contributorVOS, Robin-
item.contributorMombaerts, Peter-
item.contributorLagrou, Katrien-
item.contributorCeulemans, Laurens J.-
item.fullcitationVan Slambrouck, Jan; Schoenaers, Charlotte; Laenen , Lies; Jin, Xin; Beuselinck, Kurt; Verdonck, Ann; Wauters, Joost; MOLENBERGHS, Geert; Vanaudenaerde, Bart M.; VOS, Robin; Mombaerts, Peter; Lagrou, Katrien & Ceulemans, Laurens J. (2024) The value of point-of-care tests for the detection of SARS-CoV-2 RNA or antigen in bronchoalveolar lavage fluid. In: JOURNAL OF VIROLOGICAL METHODS, 323 (Art N° 114848).-
item.embargoEndDate2024-07-31-
crisitem.journal.issn0166-0934-
crisitem.journal.eissn1879-0984-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
The value of point-of-care tests for the detection of SARS-CoV-2 RNA or antigen in bronchoalveolar lavage fluid.pdf
  Restricted Access
Published version2.46 MBAdobe PDFView/Open    Request a copy
Manuscript_VIRMET-D-23-00305.pdf
  Until 2024-07-31
Peer-reviewed author version1.12 MBAdobe PDFView/Open    Request a copy
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.