Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/42511
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGEFEN, Amit-
dc.contributor.authorAlves, Paulo-
dc.contributor.authorBeeckman, Dimitri-
dc.contributor.authorCullen, Breda-
dc.contributor.authorLazaro-Martinez, Jose Luis-
dc.contributor.authorLev-Tov, Hadar-
dc.contributor.authorSantamaria, Nick-
dc.contributor.authorSwanson, Terry-
dc.contributor.authorWoo, Kevin-
dc.contributor.authorSoderstrom, Bengt-
dc.contributor.authorSvensby, Anna-
dc.contributor.authorMalone, Matthew-
dc.contributor.authorNygren, Erik-
dc.date.accessioned2024-03-01T09:19:31Z-
dc.date.available2024-03-01T09:19:31Z-
dc.date.issued2024-
dc.date.submitted2024-03-01T08:03:52Z-
dc.identifier.citationInternational Wound Journal, 21 (2) (Art N° e14674)-
dc.identifier.urihttp://hdl.handle.net/1942/42511-
dc.description.abstractThis article describes the contemporary bioengineering theory and practice of evaluating the fluid handling performance of foam-based dressings, with focus on the important and clinically relevant engineering structure-function relationships and on advanced laboratory testing methods for pre-clinical quantitative assessments of this common type of wound dressings. The effects of key wound dressing material-related and treatment-related physical factors on the absorbency and overall fluid handling of foam-based dressings are thoroughly and quantitively analysed. Discussions include exudate viscosity and temperature, action of mechanical forces and the dressing microstructure and associated interactions. Based on this comprehensive review, we propose a newly developed testing method, experimental metrics and clinical benchmarks that are clinically relevant and can set the standard for robust fluid handling performance evaluations. The purpose of this evaluative framework is to translate the physical characteristics and performance determinants of a foam dressing into achievable best clinical outcomes. These guiding principles are key to distinguishing desirable properties of a dressing that contribute to optimal performance in clinical settings.-
dc.description.sponsorshipThe current research was conducted by members ofthe International Wound Dressing Technology ExpertPanel (iWDTEP). The iWDTEP consists of consultantspaid by Mölnlycke Health Care AB (Gothenburg,Sweden). Mölnlycke has not controlled (or regulated)the research carried out by the members of the iWD-TEP. The authors would like to acknowledgeMs. Victoria Teng of the Physical Testing Laboratory at Mölnlycke Health Care for the performance ofexperiments using the FLUHTE wound simulatorsystem.-
dc.language.isoen-
dc.publisherWILEY-
dc.rights2024 The Authors.International Wound Journalpublished by Medicalhelplines.com Inc and John Wiley & Sons Ltd. This is an open access article under the terms of theCreative Commons Attribution-NonCommercial-NoDerivsLicense, which permits use and distribution in anymedium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made-
dc.subject.otherabsorbency and retention-
dc.subject.otheradhesion of adhesive dressings-
dc.subject.otherleakage and failure of wound care-
dc.subject.othertesting methods and standards-
dc.subject.othertreatment-
dc.titleFluid handling by foam wound dressings: From engineering theory to advanced laboratory performance evaluations-
dc.typeJournal Contribution-
dc.identifier.issue2-
dc.identifier.volume21-
local.format.pages25-
local.bibliographicCitation.jcatA1-
dc.description.notesGefen, A (corresponding author), Tel Aviv Univ, Fac Engn, Herbert J Berman Chair Vasc Bioengn, Dept Biomed Engn, IL-6997801 Tel Aviv, Israel.-
dc.description.notesgefen@tauex.tau.ac.il-
local.publisher.place111 RIVER ST, HOBOKEN 07030-5774, NJ USA-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnre14674-
dc.identifier.doi10.1111/iwj.14674-
dc.identifier.pmid38353372-
dc.identifier.isi001161410400001-
dc.contributor.orcidSantamaria, Nick/0000-0001-5270-6943; Nygren, Erik/0000-0001-6783-4622;-
dc.contributor.orcidBeeckman, Dimitri/0000-0003-3080-8716; Gefen, Amit/0000-0002-0223-7218;-
dc.contributor.orcidAlves, Paulo/0000-0002-6348-3316-
local.provider.typewosris-
local.description.affiliation[Gefen, Amit] Tel Aviv Univ, Fac Engn, Dept Biomed Engn, Tel Aviv, Israel.-
local.description.affiliation[Gefen, Amit; Beeckman, Dimitri] Univ Ghent, Univ Ctr Nursing & Midwifery, Dept Publ Hlth & Primary Care, Skin Integr Res Grp SKINT, Ghent, Belgium.-
local.description.affiliation[Gefen, Amit] Hasselt Univ, Fac Sci, Dept Math & Stat, Hasselt, Belgium.-
local.description.affiliation[Alves, Paulo] Univ Catolica Portuguesa, Fac Nursing & Hlth Sci, Ctr Interdisciplinary Res Hlth, Wounds Res Lab, Porto, Portugal.-
local.description.affiliation[Beeckman, Dimitri] Orebro Univ, Fac Med & Hlth, Swedish Ctr Skin & Wound Res, Sch Hlth Sci, Orebro, Sweden.-
local.description.affiliation[Cullen, Breda] RedC Consultancy, Bradford, England.-
local.description.affiliation[Lazaro-Martinez, Jose Luis] Univ Complutense Madrid, Diabetic Foot Unit, Madrid 28040, Spain.-
local.description.affiliation[Lev-Tov, Hadar] Univ Miami Hosp, Miller Sch Med, Dr Phillip Frost Dept Dermatol & Cutaneous Surg, Miami, FL USA.-
local.description.affiliation[Santamaria, Nick] Univ Melbourne, Sch Hlth Sci, Melbourne, Vic, Australia.-
local.description.affiliation[Swanson, Terry; Woo, Kevin] Queens Univ, Sch Nursing, Kingston, ON, Canada.-
local.description.affiliation[Svensby, Anna; Nygren, Erik] Molnlycke Hlth Care AB, Wound Care Res & Dev, Gothenburg, Sweden.-
local.description.affiliation[Soderstrom, Bengt; Malone, Matthew] Molnlycke Hlth Care AB, Res & Dev, Bioact & Wound Biol, Gothenburg, Sweden.-
local.description.affiliation[Malone, Matthew] Western Sydney Univ, Sch Med, Infect Dis & Microbiol, Sydney, NSW, Australia.-
local.description.affiliation[Gefen, Amit] Tel Aviv Univ, Fac Engn, Herbert J Berman Chair Vasc Bioengn, Dept Biomed Engn, IL-6997801 Tel Aviv, Israel.-
local.uhasselt.internationalyes-
item.fulltextWith Fulltext-
item.contributorGEFEN, Amit-
item.contributorAlves, Paulo-
item.contributorBeeckman, Dimitri-
item.contributorCullen, Breda-
item.contributorLazaro-Martinez, Jose Luis-
item.contributorLev-Tov, Hadar-
item.contributorSantamaria, Nick-
item.contributorSwanson, Terry-
item.contributorWoo, Kevin-
item.contributorSoderstrom, Bengt-
item.contributorSvensby, Anna-
item.contributorMalone, Matthew-
item.contributorNygren, Erik-
item.accessRightsOpen Access-
item.fullcitationGEFEN, Amit; Alves, Paulo; Beeckman, Dimitri; Cullen, Breda; Lazaro-Martinez, Jose Luis; Lev-Tov, Hadar; Santamaria, Nick; Swanson, Terry; Woo, Kevin; Soderstrom, Bengt; Svensby, Anna; Malone, Matthew & Nygren, Erik (2024) Fluid handling by foam wound dressings: From engineering theory to advanced laboratory performance evaluations. In: International Wound Journal, 21 (2) (Art N° e14674).-
crisitem.journal.issn1742-4801-
crisitem.journal.eissn1742-481X-
Appears in Collections:Research publications
Show simple item record

WEB OF SCIENCETM
Citations

1
checked on Oct 6, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.