Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/42670
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSCHRODER, Jonas-
dc.contributor.authorHallemans, Ann-
dc.contributor.authorSaeys, Wim-
dc.contributor.authorYperzeele, Laetitia-
dc.contributor.authorKwakkel, Gert-
dc.contributor.authorTruijen, Steven-
dc.date.accessioned2024-03-25T09:41:16Z-
dc.date.available2024-03-25T09:41:16Z-
dc.date.issued2024-
dc.date.submitted2024-03-25T09:00:41Z-
dc.identifier.citationJournal of Rehabilitation and Assistive Technologies Engineering, 11-
dc.identifier.urihttp://hdl.handle.net/1942/42670-
dc.description.abstractIntroduction: Center-of-pressure (COP) synchronization and symmetry can inform adaptations in balance control following one-sided sensorimotor impairments (e.g., stroke). As established force plates are impossible to transport, we aimed to criterion validate a portable pressure plate for obtaining reliable COP synchronization and symmetry measures, next to conventional postural stability measures. Methods: Twenty healthy adults participated. In a single session, three 40-s eyes-open and eyes-closed quiet stance trials were performed per plate-type, randomly ordered. Individual-limb COPs were measured to calculate between-limb synchronization (BLS) and dynamic control asymmetry (DCA). Net COP (i.e., limbs combined) area, amplitude, and velocity were used to describe anteroposterior (AP) and mediolateral (ML) postural stability. Criterion validity was evaluated using Spearman correlations (r) and Bland-Altman plots. Test-retest reliability was tested using intraclass correlation coefficients (ICC). Results: Strong correlations (r > 0.75) and acceptable reliability (ICC > 0.80) were found regarding individual-limb COP velocity and DCA, net COP ML amplitude and AP and ML velocities. Bland-Altman plots yielded possible proportional bias; the pressure plate systematically underestimated COP scores by force plates and a larger error associated with a larger measurement. Conclusions: Despite correlations between instruments and sufficient reliability for measuring postural stability and DCA, this technical note strongly suggests, due to a systematic deviation, using the same plate-type to accurately assess performance change within subjects longitudinally over time.-
dc.description.sponsorshipFunding The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: The authors would like to acknowledge funding by the Research Foundation Flanders (FWO), Belgium who provided JS a doctoral (PhD) grant for strategic basic research (application number 1S64819N) to conduct this research. Acknowledgments The authors would like to thank Charlotte Johnson for writing assistance, and the following M.Sc. students for aiding data collection and subject recruitment: Heleen Leurs, Carolien Van de Perck, Silke Van Goubergen, Gabriela Wimberska, Denice Kliebisch, and Sofia Lopez-Cotarelo Flemons.-
dc.language.isoen-
dc.publisherSAGE PUBLICATIONS INC-
dc.rightsThe Author(s) 2024. Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).-
dc.subject.otherReliability and validity-
dc.subject.otherpostural balanc-
dc.subject.otherposturography-
dc.subject.otherbiomechanics-
dc.subject.otherforce plate-
dc.subject.othercenter of pressure-
dc.titleIs a portable pressure plate an alternative to force plates for measuring postural stability and interlimb coordination of quiet standing balance control?-
dc.typeJournal Contribution-
dc.identifier.volume11-
local.format.pages10-
local.bibliographicCitation.jcatA1-
dc.description.notesSchröder, J (corresponding author), Hasselt Univ, Fac Rehabil Sci, REVAL Rehabil Res Ctr, Campus Diepenbeek,Wetenschapspk 7, B-3590 Hasselt, Belgium.-
dc.description.notesjonas.schroder@uhasselt.be-
local.publisher.place2455 TELLER RD, THOUSAND OAKS, CA 91320 USA-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1177/20556683241234858-
dc.identifier.isi001179529800001-
local.provider.typewosris-
local.description.affiliation[Schroder, Jonas; Hallemans, Ann; Saeys, Wim; Truijen, Steven] Univ Antwerp, Dept Rehabil Sci & Physiotherapy REVAKI, Res Grp MOVANT, Antwerp, Belgium.-
local.description.affiliation[Schroder, Jonas] Hasselt Univ, Fac Rehabil Sci, REVAL Rehabil Res Ctr, Hasselt, Belgium.-
local.description.affiliation[Saeys, Wim] RevArte Rehabil Hosp, Dept Neurorehabil, Edegem, Belgium.-
local.description.affiliation[Yperzeele, Laetitia] Antwerp Univ Hosp, Neurovasc Ctr Antwerp, Dept Neurol, Edegem, Belgium.-
local.description.affiliation[Yperzeele, Laetitia] Antwerp Univ Hosp, Dept Neurol, Stroke Unit, Edegem, Belgium.-
local.description.affiliation[Yperzeele, Laetitia] Univ Antwerp, Res Grp Translat Neurosci, Antwerp, Belgium.-
local.description.affiliation[Kwakkel, Gert] Vrije Univ Amsterdam, Dept Rehabil Med, Amsterdam Movement Sci, Amsterdam Neurosci,Amsterdam UMC, Amsterdam, Netherlands.-
local.description.affiliation[Kwakkel, Gert] Northwestern Univ, Dept Phys Therapy & Human Movement Sci, Chicago, IL USA.-
local.description.affiliation[Kwakkel, Gert] Amsterdam Rehabil Res Ctr Reade, Amsterdam, Netherlands.-
local.description.affiliation[Schroder, Jonas] Hasselt Univ, Fac Rehabil Sci, REVAL Rehabil Res Ctr, Campus Diepenbeek,Wetenschapspk 7, B-3590 Hasselt, Belgium.-
local.uhasselt.internationalyes-
item.fullcitationSCHRODER, Jonas; Hallemans, Ann; Saeys, Wim; Yperzeele, Laetitia; Kwakkel, Gert & Truijen, Steven (2024) Is a portable pressure plate an alternative to force plates for measuring postural stability and interlimb coordination of quiet standing balance control?. In: Journal of Rehabilitation and Assistive Technologies Engineering, 11.-
item.fulltextWith Fulltext-
item.contributorSCHRODER, Jonas-
item.contributorHallemans, Ann-
item.contributorSaeys, Wim-
item.contributorYperzeele, Laetitia-
item.contributorKwakkel, Gert-
item.contributorTruijen, Steven-
item.accessRightsOpen Access-
crisitem.journal.issn2055-6683-
crisitem.journal.eissn2055-6683-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Is a portable pressure plate an alternative to force plates for measuring postural stability and interlimb _.pdfPublished version1.17 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.