Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/42824
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPhilips, Tim-
dc.contributor.authorMolenaers, Ben-
dc.contributor.authorCAEKEBEKE, Pieter-
dc.contributor.authorFlies, Mike-
dc.contributor.authorVanderhaeghen, Olivier-
dc.contributor.authorDUERINCKX, Joris-
dc.date.accessioned2024-04-26T08:21:34Z-
dc.date.available2024-04-26T08:21:34Z-
dc.date.issued2024-
dc.date.submitted2024-04-23T11:40:39Z-
dc.identifier.citationARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 144 , p. 2127-2129-
dc.identifier.urihttp://hdl.handle.net/1942/42824-
dc.description.abstractIntroduction Time-efficiency of individually wrapped screws versus screws in a screw rack is not well established. Materials and methods We performed a prospective single-center clinical study timing the interval between the surgeon asking and receiving a screw during plate and screw osteosynthesis of distal radius fractures. Patients were randomized for individually wrapped screws or screws in a screw rack. The study was conducted in a Level 1 Trauma Center and surgeries were performed between March and June 2023. Results Average handling time for screws from a screw rack was 9 s (SD 5.5; range 3-28) and 22 s for individually wrapped screws (SD 6.1; range 6-38). This average difference of 13 s is significant (p < 0.0001). Conclusion There is a significant increase in handling time using individually wrapped screws over using a screw rack. Level of evidence Level I (therapeutic, randomized controlled trial).-
dc.description.sponsorshipWe would like to thank Frauke Somers, scientifc collaborator or Future Health by ZOL Genk, for her very appreciated help with all practical aspects of the study-
dc.language.isoen-
dc.publisherSPRINGER-
dc.rightsThe Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2024-
dc.subject.otherDistal radius-
dc.subject.otherFracture-
dc.subject.otherSurgery-
dc.subject.otherScrew-
dc.subject.otherEfficiency-
dc.subject.otherRack-
dc.subject.otherIndividual-
dc.titleComparison of time-efficiency of individually wrapped screws and sterile screw racks in distal radius fracture treatment-
dc.typeJournal Contribution-
dc.identifier.epage2129-
dc.identifier.spage2127-
dc.identifier.volume144-
local.format.pages3-
local.bibliographicCitation.jcatA1-
dc.description.notesDuerinckx, J (corresponding author), Ziekenhuis Oost Limburg, Dept Orthopaed Surg & Traumatol, Synaps Pk 1, B-3600 Genk, Belgium.; Duerinckx, J (corresponding author), Hasselt Univ, Fac Rehabil Sci, Agoralaan 5, B-3590 Diepenbeek, Belgium.-
dc.description.notesjoris.duerinckx@zol.be-
local.publisher.placeONE NEW YORK PLAZA, SUITE 4600, NEW YORK, NY, UNITED STATES-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1007/s00402-024-05278-6-
dc.identifier.pmid38494566-
dc.identifier.isi001186146900001-
local.provider.typewosris-
local.description.affiliation[Philips, Tim; Molenaers, Ben; Caekebeke, Pieter; Duerinckx, Joris] Ziekenhuis Oost Limburg, Dept Orthopaed Surg & Traumatol, Synaps Pk 1, B-3600 Genk, Belgium.-
local.description.affiliation[Philips, Tim] Univ Hosp Gent, Dept Orthopaed Surg & Traumatol, Corneel Heymanslaan 10, B-9000 Ghent, Belgium.-
local.description.affiliation[Duerinckx, Joris] Hasselt Univ, Fac Rehabil Sci, Agoralaan 5, B-3590 Diepenbeek, Belgium.-
local.description.affiliation[Flies, Mike; Vanderhaeghen, Olivier] DEO Care, Paalsesteenweg 170, B-3583 Beringen, Belgium.-
local.uhasselt.internationalno-
item.contributorPhilips, Tim-
item.contributorMolenaers, Ben-
item.contributorCAEKEBEKE, Pieter-
item.contributorFlies, Mike-
item.contributorVanderhaeghen, Olivier-
item.contributorDUERINCKX, Joris-
item.fullcitationPhilips, Tim; Molenaers, Ben; CAEKEBEKE, Pieter; Flies, Mike; Vanderhaeghen, Olivier & DUERINCKX, Joris (2024) Comparison of time-efficiency of individually wrapped screws and sterile screw racks in distal radius fracture treatment. In: ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 144 , p. 2127-2129.-
item.accessRightsOpen Access-
item.fulltextWith Fulltext-
crisitem.journal.issn0936-8051-
crisitem.journal.eissn1434-3916-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
rr.pdf
  Restricted Access
Published version1.02 MBAdobe PDFView/Open    Request a copy
auteursversie.pdfPeer-reviewed author version255.73 kBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.