Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/42953
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGRUWEZ, Henri-
dc.contributor.authorEzzat, Daniel-
dc.contributor.authorVan Puyvelde, Tim-
dc.contributor.authorDHONT, Sebastiaan-
dc.contributor.authorMEEKERS, Evelyne-
dc.contributor.authorBRUCKERS, Liesbeth-
dc.contributor.authorWOUTERS, Femke-
dc.contributor.authorKellens, Michiel-
dc.contributor.authorVan Herendael, Hugo-
dc.contributor.authorRivero-Ayerza, Maximo-
dc.contributor.authorNUYENS, Dieter-
dc.contributor.authorHaemers , Peter-
dc.contributor.authorPISON, Laurent-
dc.date.accessioned2024-05-15T09:08:38Z-
dc.date.available2024-05-15T09:08:38Z-
dc.date.issued2024-
dc.date.submitted2024-05-14T12:47:34Z-
dc.identifier.citationEUROPACE, 26 (4) (Art N° euae065)-
dc.identifier.urihttp://hdl.handle.net/1942/42953-
dc.description.abstractAims Photoplethysmography- (PPG) based smartphone applications facilitate heart rate and rhythm monitoring in patients with paroxysmal and persistent atrial fibrillation (AF). Despite an endorsement from the European Heart Rhythm Association, validation studies in this setting are lacking. Therefore, we evaluated the accuracy of PPG-derived heart rate and rhythm classification in subjects with an established diagnosis of AF in unsupervised real-world conditions. Methods and results Fifty consecutive patients were enrolled, 4 weeks before undergoing AF ablation. Patients used a handheld single-lead electrocardiography (ECG) device and a fingertip PPG smartphone application to record 3907 heart rhythm measurements twice daily during 8 weeks. The ECG was performed immediately before and after each PPG recording and was given a diagnosis by the majority of three blinded cardiologists. A consistent ECG diagnosis was exhibited along with PPG data of sufficient quality in 3407 measurements. A single measurement exhibited good quality more often with ECG (93.2%) compared to PPG (89.5%; P < 0.001). However, PPG signal quality improved to 96.6% with repeated measurements. Photoplethysmography-based detection of AF demonstrated excellent sensitivity [98.3%; confidence interval (CI): 96.7-99.9%], specificity (99.9%; CI: 99.8-100.0%), positive predictive value (99.6%; CI: 99.1-100.0%), and negative predictive value (99.6%; CI: 99.0-100.0%). Photoplethysmography underestimated the heart rate in AF with 6.6 b.p.m. (95% CI: 5.8 b.p.m. to 7.4 b.p.m.). Bland-Altman analysis revealed increased underestimation in high heart rates. The root mean square error was 11.8 b.p.m. Conclusion Smartphone applications using PPG can be used to monitor patients with AF in unsupervised real-world conditions. The accuracy of AF detection algorithms in this setting is excellent, but PPG-derived heart rate may tend to underestimate higher heart rates. [GRAPHICS] .-
dc.description.sponsorshipFunding H.G. is supported as predoctoral strategic basic research fellow by Research Foundation - Flanders (FWO 1S83221N). The FC app was provided by Qompium NV. Acknowledgements The authors would like to kindly thank Lieke Peeters, Sigrid Christiaens, Nicolas De Melio, and Seppe Maris for their contribution to this work.-
dc.language.isoen-
dc.publisherOXFORD UNIV PRESS-
dc.rightsThe Author(s) 2024. Published by Oxford University Press on behalf of the European Society of Cardiology. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.-
dc.subject.otherAtrial fibrillation-
dc.subject.otherMobile health-
dc.subject.otherPhotoplethysmography-
dc.subject.otherElectrocardiography-
dc.subject.otherSmartphone-
dc.titleReal-world validation of smartphone-based photoplethysmography for rate and rhythm monitoring in atrial fibrillation-
dc.typeJournal Contribution-
dc.identifier.issue4-
dc.identifier.volume26-
local.format.pages9-
local.bibliographicCitation.jcatA1-
dc.description.notesPison, L (corresponding author), Ziekenhuis Oost Limburg, Dept Cardiol, Synaps Pk 1, B-3600 Genk, Belgium.-
dc.description.noteslaurent.pison@zol.be-
local.publisher.placeGREAT CLARENDON ST, OXFORD OX2 6DP, ENGLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnreuae065-
dc.identifier.doi10.1093/europace/euae065-
dc.identifier.pmid38630867-
dc.identifier.isi001203889000002-
dc.contributor.orcidWouters, Femke/0000-0002-4420-6372-
local.provider.typewosris-
local.description.affiliation[Gruwez, Henri; Dhont, Sebastiaan; Meekers, Evelyne; Van Herendael, Hugo; Rivero-Ayerza, Maximo; Nuyens, Dieter; Pison, Laurent] Ziekenhuis Oost Limburg, Dept Cardiol, Synaps Pk 1, B-3600 Genk, Belgium.-
local.description.affiliation[Gruwez, Henri; Van Puyvelde, Tim; Meekers, Evelyne; Haemers, Peter] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium.-
local.description.affiliation[Gruwez, Henri; Ezzat, Daniel; Dhont, Sebastiaan; Meekers, Evelyne; Wouters, Femke; Kellens, Michiel; Pison, Laurent] Hasselt Univ, Fac Med & Life Sci, Limburg Clin Res Ctr, Martelarenlaan 42, B-3500 Hasselt, Belgium.-
local.description.affiliation[Bruckers, Liesbeth] Hasselt Univ, Res Inst Ctr Stat CENSTAT, Hasselt, Belgium.-
local.uhasselt.internationalno-
item.contributorGRUWEZ, Henri-
item.contributorEzzat, Daniel-
item.contributorVan Puyvelde, Tim-
item.contributorDHONT, Sebastiaan-
item.contributorMEEKERS, Evelyne-
item.contributorBRUCKERS, Liesbeth-
item.contributorWOUTERS, Femke-
item.contributorKellens, Michiel-
item.contributorVan Herendael, Hugo-
item.contributorRivero-Ayerza, Maximo-
item.contributorNUYENS, Dieter-
item.contributorHaemers , Peter-
item.contributorPISON, Laurent-
item.fullcitationGRUWEZ, Henri; Ezzat, Daniel; Van Puyvelde, Tim; DHONT, Sebastiaan; MEEKERS, Evelyne; BRUCKERS, Liesbeth; WOUTERS, Femke; Kellens, Michiel; Van Herendael, Hugo; Rivero-Ayerza, Maximo; NUYENS, Dieter; Haemers , Peter & PISON, Laurent (2024) Real-world validation of smartphone-based photoplethysmography for rate and rhythm monitoring in atrial fibrillation. In: EUROPACE, 26 (4) (Art N° euae065).-
item.fulltextWith Fulltext-
item.accessRightsOpen Access-
crisitem.journal.issn1099-5129-
crisitem.journal.eissn1532-2092-
Appears in Collections:Research publications
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.