Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/43096
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDe Potter, Tom-
dc.contributor.authorGrimaldi, Massimo-
dc.contributor.authorDuytschaever, Mattias-
dc.contributor.authorAnic, Ante-
dc.contributor.authorVIJGEN, Johan-
dc.contributor.authorNeuzil, Petr-
dc.contributor.authorVan Herendael, Hugo-
dc.contributor.authorVerma, Atul-
dc.contributor.authorSkanes, Allan-
dc.contributor.authorScherr, Daniel-
dc.contributor.authorPurerfellner, Helmut-
dc.contributor.authorRackauskas, Gediminas-
dc.contributor.authorJais, Pierre-
dc.contributor.authorReddy, Vivek Y.-
dc.date.accessioned2024-06-11T06:17:43Z-
dc.date.available2024-06-11T06:17:43Z-
dc.date.issued2024-
dc.date.submitted2024-06-07T08:48:52Z-
dc.identifier.citationCirculation-Arrhythmia and Electrophysiology, 17 (5) (Art N° e012667)-
dc.identifier.urihttp://hdl.handle.net/1942/43096-
dc.description.abstractBACKGROUND:We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study's conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success.METHODS:InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success.RESULTS:The patient cohort included 186 patients: aged 59 +/- 10 years, female 30%, and CHA2DS2-VASc 1.3 +/- 1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%-81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%-87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%-90.9%) or 94.0% (95% CI, 90.6%-97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction >= 60% (adjusted odds ratio, 0.30) and patients receiving >= 48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received >= 12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications.CONCLUSIONS:The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (>= 48 total or >= 12 per vein) resulted in an improved 1-year success rate of approximate to 80%.REGISTRATION:URL: https://www.clinicaltrials.gov; Unique identifier: NCT04524364-
dc.description.sponsorshipAcknowledgments The authors would like to express their deepest gratitude to all investigators, including coinvestigators and guest operating investigators. They wish to thank the following individuals for their support in trial design, execution, statistical analysis, medical writing, and additional value to developing the manuscript: Tara Gomez, Eric Byun, Nathalie Macours, Carmen Rousseeuw, Sarah Rabau, Lee Ming Boo, Christina Kaneko, Jaclyn Alcazar, Yanmin Wang, Tiffany Tan, Guixia Huang, Stephen Hynes, and Puneet Jatana. Michelle Hughes, BSc, with Lumanity Communications Inc. (Yardley, PA), provided medical writing and editorial support, in accordance with Good Publication Practice guidelines, which were funded by Biosense Webster, Inc, under direction of the authors.-
dc.language.isoen-
dc.publisherLIPPINCOTT WILLIAMS & WILKINS-
dc.rights2024 The Authors. Circulation: Arrhythmia and Electrophysiology is published on behalf of the American Heart Association, Inc., by Wolters Kluwer Health, Inc. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided that the original work is properly cited-
dc.subject.otheratrial fibrillation-
dc.subject.othercatheters-
dc.subject.otherelectroporation-
dc.subject.otherpulmonary veins-
dc.titlePredictors of Success for Pulmonary Vein Isolation With Pulsed-field Ablation Using a Variable-loop Catheter With 3D Mapping Integration: Complete 12-month Outcomes From inspIRE-
dc.typeJournal Contribution-
dc.identifier.issue5-
dc.identifier.volume17-
local.format.pages9-
local.bibliographicCitation.jcatA1-
dc.description.notesDe Potter, T (corresponding author), Onze Lieve Vrouw Hosp, Dienst Cardiol, Moorselbaan 164, B-9300 Aalst, Belgium.-
dc.description.notestom.de.potter@olvz-aalst.be; fiatric@hotmail.com;-
dc.description.notesMattias.Duytschaever@azsintjan.be; anteanic@gmail.com;-
dc.description.notesjohan.vijgen@jessazh.be; pneuzil@seznam.cz; hugo.vanherendael@zol.be;-
dc.description.notesatul.verma@mcgill.ca; askanes@uwo.ca; daniel.scherr@medunigraz.at;-
dc.description.notesgediminas.rackauskas@santa.lt-
local.publisher.placeTWO COMMERCE SQ, 2001 MARKET ST, PHILADELPHIA, PA 19103 USA-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnre012667-
dc.identifier.doi10.1161/CIRCEP.123.012667-
dc.identifier.pmid38655693-
dc.identifier.isi001228299100008-
dc.contributor.orcidvijgen, johan/0000-0003-4928-4836; Anic, Ante/0000-0002-6864-3999-
local.provider.typewosris-
local.description.affiliation[De Potter, Tom] Onze Lieve Vrouw Hosp, Dienst Cardiol, Moorselbaan 164, B-9300 Aalst, Belgium.-
local.description.affiliation[De Potter, Tom] Onze Lieve Vrouw Hosp, Dienst Cardiol, Aalst, Belgium.-
local.description.affiliation[Grimaldi, Massimo] Osped Gen Reg F Miulli UOC Cardiol, Bari, Italy.-
local.description.affiliation[Duytschaever, Mattias] Acad Hosp St Jan, Brugge, Belgium.-
local.description.affiliation[Anic, Ante] Univ Hosp Ctr Split, Split, Croatia.-
local.description.affiliation[Vijgen, Johan] Jessa Hosp, Hasselt, Belgium.-
local.description.affiliation[Neuzil, Petr] Homolce Hosp, Dept Cardiol, Prague, Czech Republic.-
local.description.affiliation[Van Herendael, Hugo] Ziekenhuis Oost, Genk, Belgium.-
local.description.affiliation[Verma, Atul] McGill Univ, Ctr Hlth, Montreal, PQ, Canada.-
local.description.affiliation[Skanes, Allan] Univ Western Ontario, London, ON, Canada.-
local.description.affiliation[Scherr, Daniel] Med Univ Graz, Graz, Austria.-
local.description.affiliation[Purerfellner, Helmut] Ordensklinikum Linz GmbH, Linz, Austria.-
local.description.affiliation[Rackauskas, Gediminas] Vilnius Univ, Ctr Cardiol & Angiol, Dept Cardiovasc Dis, Vilnius, Lithuania.-
local.description.affiliation[Jais, Pierre] Bordeaux Univ, Ctr Hosp Univ Bordeaux, IHU LIRYC ANR 10 IAHU 04, Bordeaux, France.-
local.description.affiliation[Reddy, Vivek Y.] Mt Sinai Fuster Heart Hosp, Helmsley Electrophysiol Ctr, New York, NY USA.-
local.description.affiliation[Reddy, Vivek Y.] Na Homolce Hosp, Dept Cardiol, Prague, Czech Republic.-
local.uhasselt.internationalyes-
item.fullcitationDe Potter, Tom; Grimaldi, Massimo; Duytschaever, Mattias; Anic, Ante; VIJGEN, Johan; Neuzil, Petr; Van Herendael, Hugo; Verma, Atul; Skanes, Allan; Scherr, Daniel; Purerfellner, Helmut; Rackauskas, Gediminas; Jais, Pierre & Reddy, Vivek Y. (2024) Predictors of Success for Pulmonary Vein Isolation With Pulsed-field Ablation Using a Variable-loop Catheter With 3D Mapping Integration: Complete 12-month Outcomes From inspIRE. In: Circulation-Arrhythmia and Electrophysiology, 17 (5) (Art N° e012667).-
item.fulltextWith Fulltext-
item.contributorDe Potter, Tom-
item.contributorGrimaldi, Massimo-
item.contributorDuytschaever, Mattias-
item.contributorAnic, Ante-
item.contributorVIJGEN, Johan-
item.contributorNeuzil, Petr-
item.contributorVan Herendael, Hugo-
item.contributorVerma, Atul-
item.contributorSkanes, Allan-
item.contributorScherr, Daniel-
item.contributorPurerfellner, Helmut-
item.contributorRackauskas, Gediminas-
item.contributorJais, Pierre-
item.contributorReddy, Vivek Y.-
item.accessRightsOpen Access-
crisitem.journal.issn1941-3149-
crisitem.journal.eissn1941-3084-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
de-potter-et-al-2024-predictors-of-success-for-pulmonary-vein-isolation-with-pulsed-field-ablation-using-a-variable.pdfPublished version783.25 kBAdobe PDFView/Open
Show simple item record

WEB OF SCIENCETM
Citations

1
checked on Sep 22, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.