Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/44444
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHuang, Man-
dc.contributor.authorYe, Lei-
dc.contributor.authorYu, Liwen-
dc.contributor.authorZhang , Yuanyuan-
dc.contributor.authorZeng, Ting-
dc.contributor.authorYang , Juan-
dc.contributor.authorTian , Fan-
dc.contributor.authorWu, Zhen-
dc.contributor.authorZhang , Xiuhua-
dc.contributor.authorHu, Chengguo-
dc.contributor.authorYANG, Nianjun-
dc.date.accessioned2024-10-08T11:40:04Z-
dc.date.available2024-10-08T11:40:04Z-
dc.date.issued2024-
dc.date.submitted2024-10-07T13:30:50Z-
dc.identifier.citationAnalytica chimica acta (Print), 1329 (Art N° 343194)-
dc.identifier.urihttp://hdl.handle.net/1942/44444-
dc.description.abstractDependable and sensitive glucose (Glu) testing in foodstuff and blood serum is highly desirable to prevent and treat diabetes. Electrochemical quantification of Glu has attracted great interests due to the advantages, including simple operation, higher sensitivity, easy miniaturization, ease of on-site and wearable detection as well as fast response. High costs and environmental dependence of enzymes pose a challenge to the electrochemical enzymatic biosensors. Nonenzymatic electrochemical Glu sensors are urgently needed to aid the Glu detection in human serum and food samples. To fabricate flexible Glu electrochemical sensors, designing suitable electrode substrate and efficient electrocatalyst is of paramount significance. Herein, the porous patterned laser-induced graphene (LIG) was fabricated on polyimide substrates through an efficient laser-inducing technology, and then used directly as the electrode substrate. Electrochemical deposition of NiCo layered double hydroxide (LDH) nanoflakes on the LIG surface was then conducted to achieve NiCo-LDH/LIG electrode as a Glu sensor. Under optimal conditions, this sensor displays a low detection limit of 0.05 mu M. Two sets of broad detection linear ranges were found to be from 0.5 to 270 mu M and from 0.27 to 3.6 mM, with high sensitivities of 9.750 mu A mu M-1 cm(-2) and 3.760 mu A mu M-1 cm(-2), respectively. The enhanced performance was ascribed to the cooperative action of NiCo-LDH and LIG, in which porous LIG provides extraordinary electroconductibility and a high surface area, while NiCo-LDH offers numerous exposed active sites and outstanding electrocatalytic performance. Practical application was further verified during the Glu detection in human serum and food samples. This research confirms that the NiCo-LDH/LIG composite is a prospective electrode for high-performance Glu sensor and provides a way of developing nonenzymatic electrochemical sensors to analyze the Glu in human serum and food samples, opening new avenues in electrochemical sensing.-
dc.description.sponsorshipThis work was financially supported by open project funding of Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules of Hubei University of China (No. KLSAOFM2302), the Natural Science Foundation of Hubei Province of China (No. 2021CFB1192) and the Graduate Innovative Fund of Wuhan Institute of Technology of China. Thanks to eceshi (www.eceshi.com) for the XRD analysis.-
dc.language.isoen-
dc.publisherELSEVIER-
dc.rights2024 Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies-
dc.subject.otherElectrochemical sensor-
dc.subject.otherGlucose-
dc.subject.otherLaser-induced graphene (LIG)-
dc.subject.otherNiCo-LDH-
dc.subject.otherNonenzymatic sensing-
dc.titleIncorporation of laser-induced graphene with hierarchical NiCo layered double hydroxide nanosheets for electrochemical determination of glucose in food and serum-
dc.typeJournal Contribution-
dc.identifier.volume1329-
local.format.pages11-
local.bibliographicCitation.jcatA1-
dc.description.notesZhang, YY (corresponding author), Wuhan Inst Technol, Sch Chem & Environm Engn, Sch Mat Sci & Engn,Hubei Key Lab Novel Reactor & G, Key Lab Green Chem Engn Proc,Minist Educ, Wuhan 430205, Peoples R China.-
dc.description.notesyyzhang@wit.edu.cn-
local.publisher.placeRADARWEG 29, 1043 NX AMSTERDAM, NETHERLANDS-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr343194-
dc.identifier.doi10.1016/j.aca.2024.343194-
dc.identifier.isi001312363500001-
local.provider.typewosris-
local.description.affiliation[Huang, Man; Ye, Lei; Yu, Liwen; Zhang, Yuanyuan; Zeng, Ting; Yang, Juan; Tian, Fan] Wuhan Inst Technol, Sch Chem & Environm Engn, Sch Mat Sci & Engn,Hubei Key Lab Novel Reactor & G, Key Lab Green Chem Engn Proc,Minist Educ, Wuhan 430205, Peoples R China.-
local.description.affiliation[Wu, Zhen; Zhang, Xiuhua] Hubei Univ, Minist Educ, Hubei Collaborat Innovat Ctr Adv Organ Chem Mat, Key Lab Synth & Applicat Organ Funct Mol,Coll Chem, Wuhan 430062, Peoples R China.-
local.description.affiliation[Hu, Chengguo] Wuhan Univ, Coll Chem & Mol Sci, Wuhan 430072, Peoples R China.-
local.description.affiliation[Yang, Nianjun] Hasselt Univ Diepenbeek, Dept Chem, B-3590 Diepenbeek, Belgium.-
local.description.affiliation[Yang, Nianjun] Hasselt Univ Diepenbeek, IMO IMOMEC, B-3590 Diepenbeek, Belgium.-
local.uhasselt.internationalyes-
item.fullcitationHuang, Man; Ye, Lei; Yu, Liwen; Zhang , Yuanyuan; Zeng, Ting; Yang , Juan; Tian , Fan; Wu, Zhen; Zhang , Xiuhua; Hu, Chengguo & YANG, Nianjun (2024) Incorporation of laser-induced graphene with hierarchical NiCo layered double hydroxide nanosheets for electrochemical determination of glucose in food and serum. In: Analytica chimica acta (Print), 1329 (Art N° 343194).-
item.fulltextWith Fulltext-
item.accessRightsRestricted Access-
item.contributorHuang, Man-
item.contributorYe, Lei-
item.contributorYu, Liwen-
item.contributorZhang , Yuanyuan-
item.contributorZeng, Ting-
item.contributorYang , Juan-
item.contributorTian , Fan-
item.contributorWu, Zhen-
item.contributorZhang , Xiuhua-
item.contributorHu, Chengguo-
item.contributorYANG, Nianjun-
crisitem.journal.issn0003-2670-
crisitem.journal.eissn1873-4324-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Incorporation of laser-induced graphene with hierarchical NiCo layered double hydroxide.pdf
  Restricted Access
Published version8.09 MBAdobe PDFView/Open    Request a copy
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.