Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/44477
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Almorad, Alexandre | - |
dc.contributor.author | Della Rocca, Domenico Giovanni | - |
dc.contributor.author | Del Monte, Alvise | - |
dc.contributor.author | VIJGEN, Johan | - |
dc.contributor.author | KOOPMAN, Pieter | - |
dc.contributor.author | Worck, Rene | - |
dc.contributor.author | Johannessen, Arne | - |
dc.contributor.author | Lepiece, Caroline | - |
dc.contributor.author | de Meester de Ravenstein, Antoine | - |
dc.contributor.author | Strisciuglio, Teresa | - |
dc.contributor.author | Poggi, Sara | - |
dc.contributor.author | Stabile, Giuseppe | - |
dc.contributor.author | La Greca, Carmelo | - |
dc.contributor.author | Kheir, Joseph Antoine | - |
dc.contributor.author | Jesel-Morel, Laurence | - |
dc.contributor.author | El Haddad, Milad | - |
dc.contributor.author | Hossein, Amin | - |
dc.contributor.author | Audiat, Charles | - |
dc.contributor.author | Scacciavillani, Roberto | - |
dc.contributor.author | Pannone, Luigi | - |
dc.contributor.author | de Asmundis, Carlo | - |
dc.contributor.author | Chierchia, Gian-Battista | - |
dc.date.accessioned | 2024-10-17T06:27:03Z | - |
dc.date.available | 2024-10-17T06:27:03Z | - |
dc.date.issued | 2024 | - |
dc.date.submitted | 2024-10-15T14:55:51Z | - |
dc.identifier.citation | EP Europace, 26 (9) (Art N° euae227) | - |
dc.identifier.uri | http://hdl.handle.net/1942/44477 | - |
dc.description.abstract | Aims Previous clinical studies on pulmonary vein isolation (PVI) with a radiofrequency balloon (RFB) reported safe and effective procedures using conventional ablation settings with 20/60 s RF delivery via posterior/anterior (PST/ANT) electrodes. The latest evidence suggests that reducing the application time to 15 s (s) on the posterior wall when facing the oesophageal region is as effective as applying 20 s. To prospectively assess whether reducing RF time on PST/ANT segments to 15/45 s can ensure sufficient quality of lesion metrics and compare the new shortened ablation settings with the conventional one in terms of safety, and effectiveness at 1-year. Methods and results A total of 641 patients from seven European centres were enrolled in a collaborative registry, with 374 in the conventional RF delivery group and 267 in the shortened RF delivery group. Procedural outcomes, lesion metrics, and safety profiles were assessed and compared between the groups. Freedom of any atrial tachycarrythmias at one year was 85.4% and 88.2% in the SHRT and CONV groups, respectively. The shortened RF delivery strategy was associated with significantly shorter procedure times (median 63.5 vs. 96.5 min, P < 0.001) and shortened fluoroscopy exposure (median 10.0 vs. 14.0 min, P < 0.001) compared to conventional delivery. Efficacy metrics, including first-pass isolation rates and time to isolation, were comparable between groups. Shortened RF delivery was associated with a lower incidence of procedural complications (1.4% vs. 5.3%, P = 0.04) and optimized thermal characteristics. Conclusion Analyses from the COLLABORATE registry demonstrate that shortening RF energy delivery times to 15/45 s (PST/ANT) during PVI with the RFB resulted in comparable freedom from recurrent atrial tachyarrhythmia compared to conventional delivery times with comparable efficiency and safety. [Graphical Abstract] | - |
dc.description.sponsorship | Funding This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors. Acknowledgements L. Montagna, S. Malara, A. Lintermans, J. Ajoury, M. Mayorga, A. Dubois, and E. Siso for their technical support and knowledge. | - |
dc.language.iso | en | - |
dc.publisher | OXFORD UNIV PRESS | - |
dc.rights | The Author(s) 2024. Published by Oxford University Press on behalf of the European Society of Cardiology. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. | - |
dc.subject.other | Pulmonary vein isolation | - |
dc.subject.other | Radiofrequency balloon | - |
dc.subject.other | Atrial fibrillation | - |
dc.subject.other | Shortened RF delivery | - |
dc.subject.other | Oesophageal temperature | - |
dc.title | Shortened radiofrequency delivery time to optimize efficiency and safety of pulmonary vein isolation with the radiofrequency balloon: insights from the COLLABORATE registry | - |
dc.type | Journal Contribution | - |
dc.identifier.issue | 9 | - |
dc.identifier.volume | 26 | - |
local.format.pages | 10 | - |
local.bibliographicCitation.jcat | A1 | - |
dc.description.notes | Almorad, A (corresponding author), Vrije Univ Brussel, Univ Ziekenhuis Brussel, Heart Rhythm Management Ctr, Postgrad Program Cardiac Electrophysiol & Pacing, Laarbeeklaan 101, B-1090 Brussels, Belgium. | - |
dc.description.notes | alexandre.almorad@uzbrussel.be | - |
local.publisher.place | GREAT CLARENDON ST, OXFORD OX2 6DP, ENGLAND | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
local.bibliographicCitation.artnr | euae227 | - |
dc.identifier.doi | 10.1093/europace/euae227 | - |
dc.identifier.pmid | 39228338 | - |
dc.identifier.isi | 001322622400001 | - |
dc.contributor.orcid | Almorad, Alexandre/0000-0002-9743-1661; Del Monte, | - |
dc.contributor.orcid | Alvise/0000-0001-6672-4931; Koopman, Pieter/0000-0002-6373-180X; Della | - |
dc.contributor.orcid | Rocca, Domenico/0000-0003-3837-3462; johannessen, | - |
dc.contributor.orcid | arne/0000-0003-0294-3750; vijgen, johan/0000-0003-4928-4836; Worck, | - |
dc.contributor.orcid | Rene/0000-0001-9501-6168 | - |
local.provider.type | wosris | - |
local.description.affiliation | [Almorad, Alexandre; Della Rocca, Domenico Giovanni; Del Monte, Alvise; Audiat, Charles; Scacciavillani, Roberto; Pannone, Luigi; de Asmundis, Carlo; Chierchia, Gian-Battista] Vrije Univ Brussel, Univ Ziekenhuis Brussel, Heart Rhythm Management Ctr, Postgrad Program Cardiac Electrophysiol & Pacing, Laarbeeklaan 101, B-1090 Brussels, Belgium. | - |
local.description.affiliation | [Vijgen, Johan; Koopman, Pieter] Jessa Ziekenhuis, Cardiol Dept, Hartcentrum Hasselt, Hasselt, Belgium. | - |
local.description.affiliation | [Worck, Rene; Johannessen, Arne] Univ Copenhagen, Gentofte Hosp, Cardiol Lab, Gentofte, Denmark. | - |
local.description.affiliation | [Lepiece, Caroline; de Meester de Ravenstein, Antoine] CHU Helora Jolimont, Cardiol Dept, Jolimont, Belgium. | - |
local.description.affiliation | [Strisciuglio, Teresa; Poggi, Sara; Stabile, Giuseppe] Mediterranea Cardioctr, Cardiol Dept, Naples, Italy. | - |
local.description.affiliation | [Strisciuglio, Teresa] Univ Naples Federico II, Cardiol Dept, Naples, Italy. | - |
local.description.affiliation | [La Greca, Carmelo; Kheir, Joseph Antoine] Fdn Poliambulanza Ist Osped, Electrophysiol Unit, Brescia, Italy. | - |
local.description.affiliation | [Jesel-Morel, Laurence] Ctr Hosp Reg Strasbourg, Cardiol Dept, Strasbourg, France. | - |
local.uhasselt.international | yes | - |
item.fulltext | With Fulltext | - |
item.contributor | Almorad, Alexandre | - |
item.contributor | Della Rocca, Domenico Giovanni | - |
item.contributor | Del Monte, Alvise | - |
item.contributor | VIJGEN, Johan | - |
item.contributor | KOOPMAN, Pieter | - |
item.contributor | Worck, Rene | - |
item.contributor | Johannessen, Arne | - |
item.contributor | Lepiece, Caroline | - |
item.contributor | de Meester de Ravenstein, Antoine | - |
item.contributor | Strisciuglio, Teresa | - |
item.contributor | Poggi, Sara | - |
item.contributor | Stabile, Giuseppe | - |
item.contributor | La Greca, Carmelo | - |
item.contributor | Kheir, Joseph Antoine | - |
item.contributor | Jesel-Morel, Laurence | - |
item.contributor | El Haddad, Milad | - |
item.contributor | Hossein, Amin | - |
item.contributor | Audiat, Charles | - |
item.contributor | Scacciavillani, Roberto | - |
item.contributor | Pannone, Luigi | - |
item.contributor | de Asmundis, Carlo | - |
item.contributor | Chierchia, Gian-Battista | - |
item.fullcitation | Almorad, Alexandre; Della Rocca, Domenico Giovanni; Del Monte, Alvise; VIJGEN, Johan; KOOPMAN, Pieter; Worck, Rene; Johannessen, Arne; Lepiece, Caroline; de Meester de Ravenstein, Antoine; Strisciuglio, Teresa; Poggi, Sara; Stabile, Giuseppe; La Greca, Carmelo; Kheir, Joseph Antoine; Jesel-Morel, Laurence; El Haddad, Milad; Hossein, Amin; Audiat, Charles; Scacciavillani, Roberto; Pannone, Luigi; de Asmundis, Carlo & Chierchia, Gian-Battista (2024) Shortened radiofrequency delivery time to optimize efficiency and safety of pulmonary vein isolation with the radiofrequency balloon: insights from the COLLABORATE registry. In: EP Europace, 26 (9) (Art N° euae227). | - |
item.accessRights | Open Access | - |
crisitem.journal.issn | 1099-5129 | - |
crisitem.journal.eissn | 1532-2092 | - |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Shortened radiofrequency delivery time to optimize efficiency and safety .pdf | Published version | 379.72 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.