Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/45052
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Martinho, Tiago | - |
dc.contributor.author | CAEKEBEKE, Pieter | - |
dc.contributor.author | Verstuyft, Lotte | - |
dc.contributor.author | van Riet, Roger | - |
dc.date.accessioned | 2025-01-10T12:53:17Z | - |
dc.date.available | 2025-01-10T12:53:17Z | - |
dc.date.issued | 2024 | - |
dc.date.submitted | 2024-12-23T15:11:36Z | - |
dc.identifier.citation | Shoulder & Elbow, | - |
dc.identifier.uri | http://hdl.handle.net/1942/45052 | - |
dc.description.abstract | Radiocapitellar arthroplasty has been shown to improve pain and function in patients with a degenerative joint. Due to problems with the loosening of the radial head component, one of the few available systems was removed from the global market. This offered specific challenges in terms of treatment strategies when one or both components of a system that is no longer available fail. Due to the very different geometry of the capitellar implant, revision of the capitellar component would require a complex procedure, likely requiring bone graft and a high chance of early failure, leaving resection or interposition arthroplasty as the only available option. Although implant mismatch is common practice in hip and knee arthroplasty with satisfactory results, it should remain a salvage option as the off-label use of components gives rise to several medicolegal implications. We report two cases of radiocapitellar arthroplasty partial revision, by replacing only the radial head component with an implant from another system while keeping the well-fixed original capitellar component in place. At a minimum of three-year follow-up, both cases improved from poor to good and excellent Mayo elbow performance scores. There were no signs of implant failure on standard radiographs. | - |
dc.language.iso | en | - |
dc.publisher | SAGE PUBLICATIONS INC | - |
dc.rights | The Author(s) 2024 | - |
dc.subject.other | Radial head arthroplasty | - |
dc.subject.other | Radial head arthroplasty | - |
dc.subject.other | radial head replacement | - |
dc.subject.other | radial head replacement | - |
dc.subject.other | radial head prosthesis | - |
dc.subject.other | radial head prosthesis | - |
dc.subject.other | revision radial head arthroplasty | - |
dc.subject.other | revision radial head arthroplasty | - |
dc.subject.other | elbow | - |
dc.subject.other | elbow | - |
dc.subject.other | osteoarthritis | - |
dc.subject.other | osteoarthritis | - |
dc.title | Revision radiocapitellar arthroplasty by mismatched implant components - A salvage option: A report of two cases with a minimum three-year follow-up | - |
dc.type | Journal Contribution | - |
local.format.pages | 6 | - |
local.bibliographicCitation.jcat | A1 | - |
dc.description.notes | van Riet, R (corresponding author), AZ Monica, Dept Orthopaed Surg, Stevenslei 20, B-2100 Antwerp, Belgium.; van Riet, R (corresponding author), Harley St Specialist Hosp, London W1G 8HU, England. | - |
dc.description.notes | drrogervanriet@azmonica.be | - |
local.publisher.place | 2455 TELLER RD, THOUSAND OAKS, CA 91320 USA | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
local.bibliographicCitation.status | Early view | - |
dc.identifier.doi | 10.1177/17585732241297152 | - |
dc.identifier.pmid | 39664167 | - |
dc.identifier.isi | 001373232500001 | - |
local.provider.type | wosris | - |
local.description.affiliation | [Martinho, Tiago] Tour Hosp, Div Orthopaed & Trauma Surg, Meyrin, Switzerland. | - |
local.description.affiliation | [Martinho, Tiago] Univ Geneva, Fac Med, Geneva, Switzerland. | - |
local.description.affiliation | [Caekebeke, Pieter] Ziekenhuis Oost Limburg, Dept Orthopaed Surg, Genk, Belgium. | - |
local.description.affiliation | [Caekebeke, Pieter] Univ Hasselt, Fac Rehabil Sci, Hasselt, Belgium. | - |
local.description.affiliation | [Verstuyft, Lotte] AZ Sint Lucas, Dept Orthopaed Surg & Traumatol, Ghent, Belgium. | - |
local.description.affiliation | [van Riet, Roger] AZ Monica, Dept Orthopaed Surg, Stevenslei 20, B-2100 Antwerp, Belgium. | - |
local.description.affiliation | [van Riet, Roger] Univ Hosp Antwerp, Antwerp, Belgium. | - |
local.uhasselt.international | yes | - |
item.contributor | Martinho, Tiago | - |
item.contributor | CAEKEBEKE, Pieter | - |
item.contributor | Verstuyft, Lotte | - |
item.contributor | van Riet, Roger | - |
item.fullcitation | Martinho, Tiago; CAEKEBEKE, Pieter; Verstuyft, Lotte & van Riet, Roger (2024) Revision radiocapitellar arthroplasty by mismatched implant components - A salvage option: A report of two cases with a minimum three-year follow-up. In: Shoulder & Elbow,. | - |
item.accessRights | Open Access | - |
item.fulltext | With Fulltext | - |
crisitem.journal.issn | 1758-5732 | - |
crisitem.journal.eissn | 1758-5740 | - |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Revision radiocapitellar arthroplasty by mismatched implant components .pdf Restricted Access | Early view | 1.9 MB | Adobe PDF | View/Open Request a copy |
zz.pdf | Peer-reviewed author version | 20.45 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.