Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/45783
Title: Time-dependency of test-retest reliability and measurement error of center-of-pressure synchronization and symmetry during quiet standing within specific frequencies in early sub-acute stroke
Authors: van Hinsberg, Amber
Saeys, Wim
Hallemans, Ann
Kwakkel, Gert
Yperzeele, Laetitia
Truijen, Steven
SCHRODER, Jonas 
Issue Date: 2025
Publisher: ELSEVIER IRELAND LTD
Source: Gait & posture, 119 , p. 110 -117
Abstract: Background: People with unilateral sensorimotor impairments after a stroke exhibit poor between-limb synchronization and asymmetries in balance control by relying on their less-affected side to maintain stability during standing. Therefore, there is a growing consensus to include center-of-pressure metrics as between-limb synchronization and dynamic control asymmetry when investigating balance improvements poststroke. However, the test-retest reliability of these metrics remains under-investigated, hindering uptake of these assessments in future stroke rehabilitation and recovery studies. Research question: First, are three immediate test-repetitions necessary for obtaining reliable synchronization and asymmetry scores in individuals with sub-acute stroke, or can fewer repetitions suffice? Second, does timing of assessments at 3-, 5-, 8-, and 12-weeks poststroke affect these estimates' test-retest reliability and measurement error? Methods: Thirty stroke survivors with moderate-to-severe motor impairments were tested at 3-, 5-, 8-, and 12weeks poststroke. At each timepoint, they completed three 40-second quiet standing trials on a dual force plate which measured center-of-pressure signals separately on each side. We calculated between-limb synchronization (i.e., cross-correlation) and dynamic control asymmetry (i.e., symmetry index) using the original centerof-pressure signal, and after decomposition into high and low (cut-off 0.4 Hz) frequency bands. Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to assess test-retest reliability and measurement error. A cut-off was used to determine acceptable reliability (ICC>0.75). Results: Between-limb synchronization and dynamic control asymmetry showed good-to-excellent reliability (ICCs=0.80-0.97) across three repetitions at all timepoints. Reducing to two repetitions yielded acceptable reliability (ICC=0.77-0.95) for dynamic control asymmetry and high-frequency measures, yet insufficient reliability for between-limb synchronization. At the 3-weeks timepoint, ICCs were generally lower, with more error, compared to later timepoints. Conclusion: Novel performance metrics quantifying synchronization and asymmetry of balance control can be reliably obtained during the early sub-acute phase if three test-repetitions are administered per assessment.
Notes: Schröder, J (corresponding author), Campus Diepenbeek,Wetenschapspk 7, B-3590 Diepenbeek, Belgium.
jonas.schroder@uhasselt.be
Keywords: Stroke;Balance;Reliability;Force plate;Measurement error;Center of Pressure
Document URI: http://hdl.handle.net/1942/45783
ISSN: 0966-6362
e-ISSN: 1879-2219
DOI: 10.1016/j.gaitpost.2025.02.026
ISI #: 001441255400001
Rights: 2025 Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
Category: A1
Type: Journal Contribution
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
Time-dependency of test-retest reliability and measurement error of center-of-pressure synchronization and symmetry .pdf
  Restricted Access
Published version2.14 MBAdobe PDFView/Open    Request a copy
AC.pdf
  Until 2025-12-01
Peer-reviewed author version1.15 MBAdobe PDFView/Open    Request a copy
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.