Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/46016
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lathouwers, Elke | - |
dc.contributor.author | Maricot, Alexandre | - |
dc.contributor.author | TASSIGNON, Bruno | - |
dc.contributor.author | Geers, Sybille | - |
dc.contributor.author | Flynn, Louis | - |
dc.contributor.author | Verstraten, Tom | - |
dc.contributor.author | De Pauw, Kevin | - |
dc.date.accessioned | 2025-05-19T06:31:39Z | - |
dc.date.available | 2025-05-19T06:31:39Z | - |
dc.date.issued | 2025 | - |
dc.date.submitted | 2025-05-16T13:43:28Z | - |
dc.identifier.citation | Journal of Neuroengineering and Rehabilitation, 22 (1) (Art N° 105) | - |
dc.identifier.uri | http://hdl.handle.net/1942/46016 | - |
dc.description.abstract | Background Evaluation studies on active microprocessor-controlled knees (AMPK) in individuals with unilateral transfemoral amputation (TFA) are lacking in the literature. Furthermore, research on user accommodation to AMPK remains to be investigated. Hence, this study aims to conduct a comparison between an AMPK and individual's current prosthesis and assess the accommodation to using an AMPK during daily activities over a 5-week period on functional performance tests. Methods Participants with TFA completed a protocol comprising L-test, slope walking, level walking (2MWT) and dual-task level walking (dual-2MWT) once a week with their current prosthesis and the AMPK. The outcomes of interest were the distance covered during the 2MWT and dual-2MWT, time required to perform the L-test, accuracy of the serial subtractions during the dual-2MWT, heart rate (HR), rating of perceived exertion, fatigue, comfort and perceived workload. Generalised least-squared models were built to investigate differences in prosthetic conditions over time. Pearson correlations were calculated to determine associations between the performance and subjective outcomes. The level of significance was set at 0.05. Results Seven participants (age = 53 years +/- 14 years) completed the study. Over time, the AMPK participants took longer to complete the L-test than their current prosthesis (p < 0.001). They reported higher fatigue (p = 0.033), lower comfort (p = 0.010), and higher perceived exertion with the AMPK (p = 0.048). Slope walking showed no significant walking speed or HR differences except higher HR with the AMPK in session 3 (p = 0.032). Dual-task level walking demonstrated lower walking speed with the AMPK (p = 0.035) and more responses to serial subtractions in sessions two (p = 0.043) and four (p = 0.023). No other differences between conditions were found on one of the functional tests. Weak associations (|r|= 0-0.5) were observed between performance and subjective measures. Conclusion Using the AMPK highlights initial challenges in task completion times and subjective comfort and fatigue levels. Our findings indicate that five one-hour sessions are insufficient for achieving user accommodation, and underscore the need for further research with a larger sample, continued prosthetic use and user accommodation to enhance prosthetic functioning and user experiences. Trial registration: NCT05407545. | - |
dc.description.sponsorship | Funding This work was supported by the Federal Public Service for Policy and Support (AidWear project) and is part of the SRP77 Exercise and the Brain in Health & Disease: The Added Value of Human-Centered Robotics. Acknowledgements We thank Össur ehf for their willingness to provide the Power Knee™ and ProFlex XC for conducting this study. We also extend our gratitude to OrthoMatton for patient recruitment and thank Jonathan Slattery and Sien Muylaert for their assistance in the data collection. | - |
dc.language.iso | en | - |
dc.publisher | BMC | - |
dc.rights | The Author(s) 2025. Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modifed the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/. | - |
dc.subject.other | Lower-limb amputation | - |
dc.subject.other | Prosthesis | - |
dc.subject.other | Accommodation | - |
dc.subject.other | Microprocessor-controlled knee | - |
dc.title | User accommodation to an active microprocessor-controlled knee in individuals with unilateral transfemoral amputation: a 5-week non-randomized trial | - |
dc.type | Journal Contribution | - |
dc.identifier.issue | 1 | - |
dc.identifier.volume | 22 | - |
local.format.pages | 15 | - |
local.bibliographicCitation.jcat | A1 | - |
dc.description.notes | De Pauw, K (corresponding author), Vrije Univ Brussel, Human Physiol & Sports Physiotherapy Res Grp, B-1050 Brussels, Belgium.; De Pauw, K (corresponding author), Vrije Univ Brussel, Brussels Human Robot Res Ctr BruBot, B-1050 Brussels, Belgium. | - |
dc.description.notes | kevin.de.pauw@vub.be | - |
local.publisher.place | CAMPUS, 4 CRINAN ST, LONDON N1 9XW, ENGLAND | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
local.bibliographicCitation.artnr | 105 | - |
dc.identifier.doi | 10.1186/s12984-025-01637-5 | - |
dc.identifier.pmid | 40329316 | - |
dc.identifier.isi | 001482939900001 | - |
local.provider.type | wosris | - |
local.description.affiliation | [Lathouwers, Elke; Maricot, Alexandre; Tassignon, Bruno; De Pauw, Kevin] Vrije Univ Brussel, Human Physiol & Sports Physiotherapy Res Grp, B-1050 Brussels, Belgium. | - |
local.description.affiliation | [Lathouwers, Elke; Flynn, Louis; Verstraten, Tom; De Pauw, Kevin] Vrije Univ Brussel, Brussels Human Robot Res Ctr BruBot, B-1050 Brussels, Belgium. | - |
local.description.affiliation | [Tassignon, Bruno] Hasselt Univ, Fac Rehabil Sci, REVAL Rehabil Res Ctr, Diepenbeek, Belgium. | - |
local.description.affiliation | [Geers, Sybille] Ghent Univ Hosp, Unit Phys & Rehabil Med, B-9000 Ghent, Belgium. | - |
local.description.affiliation | [Flynn, Louis; Verstraten, Tom] Vrije Univ Brussel, Robot & Multibody Mech Res Grp, B-1050 Brussels, Belgium. | - |
local.uhasselt.international | no | - |
item.contributor | Lathouwers, Elke | - |
item.contributor | Maricot, Alexandre | - |
item.contributor | TASSIGNON, Bruno | - |
item.contributor | Geers, Sybille | - |
item.contributor | Flynn, Louis | - |
item.contributor | Verstraten, Tom | - |
item.contributor | De Pauw, Kevin | - |
item.fullcitation | Lathouwers, Elke; Maricot, Alexandre; TASSIGNON, Bruno; Geers, Sybille; Flynn, Louis; Verstraten, Tom & De Pauw, Kevin (2025) User accommodation to an active microprocessor-controlled knee in individuals with unilateral transfemoral amputation: a 5-week non-randomized trial. In: Journal of Neuroengineering and Rehabilitation, 22 (1) (Art N° 105). | - |
item.accessRights | Closed Access | - |
item.fulltext | With Fulltext | - |
crisitem.journal.eissn | 1743-0003 | - |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
User accommodation to an active microprocessor-controlled knee.pdf | 904.3 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.