Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/46157
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGOOSSENS, Juul-
dc.contributor.authorOUDEBROUCKX, Gilles-
dc.contributor.authorVANDENRYT, Thijs-
dc.contributor.authorTHOELEN, Ronald-
dc.date.accessioned2025-06-12T12:35:26Z-
dc.date.available2025-06-12T12:35:26Z-
dc.date.issued2025-
dc.date.submitted2025-06-04T09:26:51Z-
dc.identifier.citationTalanta, 295 (Art N° 128193)-
dc.identifier.urihttp://hdl.handle.net/1942/46157-
dc.description.abstractCell count and viability are critical parameters in biological research, drug discovery, and bioprocessing. Traditional methods for assessing these metrics often rely on destructive, end-point analyses. This research presents a novel multi-parameter sensing platform that enables concurrent analysis of cell viability and count in a microplate format. The platform combines thermal-based and impedance-based sensing to harness the distinct responses of these methods to variations in cell number and viability. Crucially, both techniques are influenced by cell viability and count, but to different degrees. This difference in sensitivity allows for the exploitation of both methods to independently assess these parameters. Thermal sensing primarily quantifies cell biomass, while impedance measurements are more sensitive to membrane integrity changes associated with cell viability. The integration of these sensing elements into a standard microwell format facilitates real-time and label-free measurements. Experiments with Saccharomyces cerevisiae cultures at various concentrations and viability states demonstrated the platform's capabilities. Multivariate regression models were developed to independently predict cell number and viability, achieving root mean square errors of 0.106 x107 cells and 19.67% viability respectively. Notably, performance improved at higher cell concentrations, with viability prediction error reduced to 5.02%. This integrated approach shows promise for continuous, non-destructive monitoring of cell cultures, offering a cost-effective alternative to traditional end-point analysis methods. The platform's ability to provide real-time insights into cell population dynamics could significantly enhance various applications in biotechnology, including bioprocess optimization, drug screening, and toxicity testing. Furthermore, its compatibility with standard microplate formats facilitates easy integration into existing laboratory workflows.-
dc.description.sponsorshipThe authors would like to thank the Biomedical Research Institute at UHasselt (BIOMED) for providing the FACS analysis. They would also like to thank Dieter Reenaers for the assistance in microscopy analysis and cell counting of cell cultures. Additionally, they would like to thank Kato Nelissen for the preliminary measurements and valuable insights-
dc.language.isoen-
dc.publisherELSEVIER-
dc.rights2025 Published by Elsevier B.V.-
dc.subject.otherSensor fusion-
dc.subject.otherEIS-
dc.subject.otherThermal sensing-
dc.subject.otherMicroplate format-
dc.subject.otherViability-
dc.subject.otherCell count-
dc.titleMicroplate-based impedance and thermal sensing system for concurrent cell viability and counting analysis-
dc.typeJournal Contribution-
dc.identifier.volume295-
local.format.pages9-
local.bibliographicCitation.jcatA1-
dc.description.notesGoossens, J (corresponding author), Hasselt Univ, Inst Mat Res IMO, Wetenschapspark 1, B-3590 Diepenbeek, Belgium.-
dc.description.notesjuul.goossens@uhasselt.be; gilles.oudebrouckx@uhasselt.be;-
dc.description.notesthijs.vandenryt@uhasselt.be; ronald.thoelen@uhasselt.be-
local.publisher.placeRADARWEG 29, 1043 NX AMSTERDAM, NETHERLANDS-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr128193-
dc.identifier.doi10.1016/j.talanta.2025.128193-
dc.identifier.pmid40349657-
dc.identifier.isi001491198100004-
local.provider.typewosris-
local.description.affiliation[Goossens, J.; Oudebrouckx, G.; Vandenryt, T.; Thoelen, R.] Hasselt Univ, Inst Mat Res IMO, Wetenschapspark 1, B-3590 Diepenbeek, Belgium.-
local.description.affiliation[Goossens, J.; Oudebrouckx, G.; Vandenryt, T.; Thoelen, R.] IMEC vzw, Div IMOMEC, B-3590 Diepenbeek, Limburg, Belgium.-
local.uhasselt.internationalno-
item.contributorGOOSSENS, Juul-
item.contributorOUDEBROUCKX, Gilles-
item.contributorVANDENRYT, Thijs-
item.contributorTHOELEN, Ronald-
item.fullcitationGOOSSENS, Juul; OUDEBROUCKX, Gilles; VANDENRYT, Thijs & THOELEN, Ronald (2025) Microplate-based impedance and thermal sensing system for concurrent cell viability and counting analysis. In: Talanta, 295 (Art N° 128193).-
item.fulltextWith Fulltext-
item.accessRightsRestricted Access-
crisitem.journal.issn0039-9140-
crisitem.journal.eissn1873-3573-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Microplate-based impedance and thermal sensing system for concurrent cell viability and counting analysis.pdf
  Restricted Access
Published version2.52 MBAdobe PDFView/Open    Request a copy
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.