Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/46601
Title: | Ultrasound shear wave elastography for detection of myocardial fibrosis | Authors: | Petrescu, Aniela Cvijic, Marta Wouters , Laurine Youssef, Ahmed Bezy, Stephanie Orlowska, Marta Degtiarova, Ganna DUCHENNE, Jürgen Bogaert, Jan D'hooge, Jan Voigt, Jens-Uwe |
Issue Date: | 2025 | Publisher: | OXFORD UNIV PRESS | Source: | European Heart Journal-Cardiovascular Imaging, | Status: | Early view | Abstract: | Aims Diffuse interstitial or replacement fibrosis is a common feature of a large variety of cardiomyopathies. These alterations contribute to increased myocardial stiffness (MS). Echocardiographic shear wave (SW) elastography is an emerging approach for measuring MS in vivo. SWs occur after mechanical excitation of the myocardium, e.g. after mitral valve closure, and their propagation velocity is directly related to MS. The objective of this study was to investigate whether SW velocities (SWVs) can distinguish between interstitial and replacement fibrosis. Methods and results Fifty-two patients [30 heart transplanted patients (52.6 +/- 16.0 years, 80% male) and 22 hypertrophic cardiomyopathy patients (54.4 +/- 15.6 years, 85% male)] and 37 healthy volunteers (47.2 +/- 16.6 years, 76% male) were included. SW elastography was performed using an experimental scanner at 1172 +/- 302 frames per second. Patients were classified according to T-1 mapping, extracellular volume (ECV) mapping, and late gadolinium enhancement measured by cardiac magnetic resonance into three groups: no fibrosis, interstitial fibrosis (MIF), and replacement fibrosis (MRF). SWVs differed among groups (P < 0.001), with a significant post hoc test between MIF and MRF and subjects without fibrosis (6.5 +/- 1.1 m/s and 8.7 +/- 1.2 m/s, respectively). Significant correlations were noted between SWVs and ECV values (r = 0.70, P < 0.0001) and native T-1 values (r = 0.48, P = 0.0004). SWVs below 6.0 m/s showed the highest accuracy to identify patients without fibrosis [sensitivity 90%, specificity 90%, area under the curve (AUC) = 0.95]. A cut-off of 8.1 m/s could distinguish MRF from MIF (sensitivity 69%, specificity 100%, AUC = 0.92). Conclusion Natural SWVs can distinguish between normal and pathological myocardium and depend on the fibrosis burden of the myocardium. | Notes: | Voigt, JU (corresponding author), Katholieke Univ Leuven, Dept Cardiovasc Sci, Herestraat 49, B-3000 Leuven, Belgium.; Voigt, JU (corresponding author), Univ Hosp Leuven, Dept Cardiovasc Dis, Herestr 49, B-3000 Leuven, Belgium. jens-uwe.voigt@uzleuven.be |
Keywords: | high-frame-rate echocardiography;shear wave;myocardial stiffness;myocardial fibrosis | Document URI: | http://hdl.handle.net/1942/46601 | ISSN: | 2047-2404 | e-ISSN: | 2047-2412 | DOI: | 10.1093/ehjci/jeaf200 | ISI #: | 001543845300001 | Category: | A1 | Type: | Journal Contribution |
Appears in Collections: | Research publications |
Show full item record
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.