Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/47979
Full metadata record
DC FieldValueLanguage
dc.contributor.authorShirinskiy, Igor J.-
dc.contributor.authorMacken, Arno A.-
dc.contributor.authorCAEKEBEKE, Pieter-
dc.contributor.authorvan Deurzen, Derek F. P.-
dc.contributor.authorTuijthof, Gabrielle J. M.-
dc.contributor.authorAlta, Tjarco D. W.-
dc.contributor.authorBleys, Ronald L. A. W.-
dc.contributor.authorJanssen, Rob P. A.-
dc.contributor.authorvan den Bekerom, Michel P. J.-
dc.date.accessioned2026-01-06T10:07:20Z-
dc.date.available2026-01-06T10:07:20Z-
dc.date.issued2025-
dc.date.submitted2026-01-05T14:19:46Z-
dc.identifier.citationJSES international, 9 (4) , p. 1199 -1204-
dc.identifier.urihttp://hdl.handle.net/1942/47979-
dc.description.abstractBackground: Although variations in fixation techniques for proximal biceps tenodesis have been evaluated by different biomechanical studies, the optimal fixation technique remains unclear. To further advance the biceps tenodesis technique using unicortical button, a novel curved button was developed. This study aimed to compare the time-zero biomechanical performance of a curved intramedullary button with that of a standard flat button in proximal biceps tenodesis. Methods: A total of 16 cadaveric fresh-frozen shoulders were randomly allocated to undergo proximal biceps tenodesis using either a standard flat button or the new curved button (developed by Materialise, Leuven, Belgium). Following the tenodesis, the biceps tendon was subjected to a cyclic load, ranging from 5 to 100N, at a frequency of 2.5 Hz for a total of 1000 cycles. After this, the tendon was loaded to failure. During testing, displacement after cyclic loading, ultimate failure load, stiffness, and modes of failure were evaluated. Results: All 16 specimens were included in the data analysis. No failure occurred during cyclic testing. After cyclic testing, the median displacement was 10.4 mm (6.1-16.1) for curved button and 11.9 mm (6.043.9) for flat button (P = .534). The mean ultimate load to failure for the curved button was 239.4 +/- 35.1 N, and 227.0 +/- 42.0 N for the flat button (P = .721). The mean stiffness was 70.0 +/- 10.3 N/mm for the curved button and 61.3 +/- 17.3 N/mm for the flat button (P = .242). Conclusions: In this time-zero in-vitro study, the curved and flat buttons exhibited similar biomechanical properties in terms of displacement, load to failure, and stiffness. Considering these results and the theoretical advantages of the curved button, this technique could be a new alternative for the treatment of proximal long-head biceps tendon pathology. (c) 2025 The Author(s). Published by Elsevier Inc. on behalf of American Shoulder and Elbow Surgeons. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).-
dc.description.sponsorshipArthroscopy & Arthroplasty Courses Utrecht 2023; Orthopaedic Research-
dc.language.isoen-
dc.publisherELSEVIER-
dc.rights2025 The Author(s). Published by Elsevier Inc. on behalf of American Shoulder and Elbow Surgeons. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).-
dc.subject.otherProximal-
dc.subject.otherFixation-
dc.subject.otherIntramedullary-
dc.subject.otherButton-
dc.subject.otherRepair-
dc.subject.otherTendon-
dc.subject.otherBiceps-
dc.titleEvaluation of a curved intramedullary button vs. traditional flat button for proximal biceps tenodesis: a biomechanical study-
dc.typeJournal Contribution-
dc.identifier.epage1204-
dc.identifier.issue4-
dc.identifier.spage1199-
dc.identifier.volume9-
local.format.pages6-
local.bibliographicCitation.jcatA1-
dc.description.notesvan den Bekerom, MPJ (corresponding author), Vrije Univ Amsterdam, Fac Behav & Movement Sci, Dept Human Movement Sci, Amsterdam Movement Sci, De Boelelaan 1105, NL-1081 HV Amsterdam, Netherlands.; van den Bekerom, MPJ (corresponding author), OLVG, Amsterdam Shoulder & Elbow Ctr Expertise, Amsterdam, Netherlands.-
dc.description.notesm.p.j.vanden.bekerom@vu.nl-
local.publisher.placeRADARWEG 29, 1043 NX AMSTERDAM, NETHERLANDS-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1016/j.jseint.2025.03.020-
dc.identifier.pmid40959037-
dc.identifier.isi001634899200029-
local.provider.typewosris-
local.description.affiliation[Shirinskiy, Igor J.; van den Bekerom, Michel P. J.] Vrije Univ Amsterdam, Fac Behav & Movement Sci, Dept Human Movement Sci, Amsterdam Movement Sci, De Boelelaan 1105, NL-1081 HV Amsterdam, Netherlands.-
local.description.affiliation[Shirinskiy, Igor J.; van den Bekerom, Michel P. J.] OLVG, Dept Orthoped Surg, Shoulder & Elbow Unit, Amsterdam, Netherlands.-
local.description.affiliation[Macken, Arno A.] Clin Gen Annecy, Alps Surg Inst, Annecy, France.-
local.description.affiliation[Macken, Arno A.] Erasmus MC, Dept Orthopaed & Sports Med, Rotterdam, Netherlands.-
local.description.affiliation[Caekebeke, Pieter] Ziekenhuis Oost Limburg, Dept Orthopaed & Traumatol, Genk, Belgium.-
local.description.affiliation[Caekebeke, Pieter] Univ Hasselt, Fac Rehabil Sci, Hasselt, Belgium.-
local.description.affiliation[van Deurzen, Derek F. P.; van den Bekerom, Michel P. J.] OLVG, Amsterdam Shoulder & Elbow Ctr Expertise, Amsterdam, Netherlands.-
local.description.affiliation[Tuijthof, Gabrielle J. M.] Univ Twente, Dept Biomech Engn, Enschede, Netherlands.-
local.description.affiliation[Alta, Tjarco D. W.] Spaarne Gasthuis, Dept Orthopaed & Traumatol, Haarlem Hoofddorp, Netherlands.-
local.description.affiliation[Bleys, Ronald L. A. W.] Univ Med Ctr Utrecht, Dept Anat, Utrecht, Netherlands.-
local.description.affiliation[Bleys, Ronald L. A. W.; Janssen, Rob P. A.] Maxima Med Ctr, Dept Orthopaed Surg & Trauma, Eindhoven, Netherlands.-
local.description.affiliation[Janssen, Rob P. A.] Eindhoven Univ Technol, Dept Biomed Engn, Orthopaed Biomech, Eindhoven, Netherlands.-
local.description.affiliation[Janssen, Rob P. A.] Fontys Univ Appl Sci, Dept Paramed Sci Hlth Innovat & Technol, Eindhoven, Netherlands.-
local.uhasselt.internationalyes-
item.fulltextWith Fulltext-
item.contributorShirinskiy, Igor J.-
item.contributorMacken, Arno A.-
item.contributorCAEKEBEKE, Pieter-
item.contributorvan Deurzen, Derek F. P.-
item.contributorTuijthof, Gabrielle J. M.-
item.contributorAlta, Tjarco D. W.-
item.contributorBleys, Ronald L. A. W.-
item.contributorJanssen, Rob P. A.-
item.contributorvan den Bekerom, Michel P. J.-
item.accessRightsOpen Access-
item.fullcitationShirinskiy, Igor J.; Macken, Arno A.; CAEKEBEKE, Pieter; van Deurzen, Derek F. P.; Tuijthof, Gabrielle J. M.; Alta, Tjarco D. W.; Bleys, Ronald L. A. W.; Janssen, Rob P. A. & van den Bekerom, Michel P. J. (2025) Evaluation of a curved intramedullary button vs. traditional flat button for proximal biceps tenodesis: a biomechanical study. In: JSES international, 9 (4) , p. 1199 -1204.-
crisitem.journal.eissn2666-6383-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
main.pdfPublished version1.39 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.