dc.identifier.citationJournal of tissue viability, 35 (1) (Art N° 100977)-
dc.identifier.urihttp://hdl.handle.net/1942/48097-
dc.description.abstractBackground: Single-use negative-pressure wound therapy (suNPWT) dressings for closed surgical incisions are predominantly rectangular, despite long-time evidence from biomechanics that sharp or small-radius corners generate localized stress concentrations in underlying tissues. Optimizing dressing geometry and stiffness distribution may reduce the peri-incisional stress concentrations and improve closure. Objectives: To determine how dressing shape and regional stiffness variations influence the peri-wound skin stresses and stress concentrations and the incision closure biomechanics under a negative pressure level of-125 mmHg. Methods: A validated three-dimensional finite element model of a sutured midline incision was developed. Five homogeneous dressing shapes (rectangular, circular, elliptical, stadium, and dome) of identical contact area and material properties were compared for reduction in peak lateral skin stresses (Delta S). The best-performing dressing shape underwent further testing in eight stiffness configurations (homogeneous, or with stiffer/softer peripheral regions in symmetric or axisymmetric patterns). The lateral displacement of the peri-wound skin was used as a measure for the closure work. A sensitivity analysis was conducted on chosen model variants for broader transferability and for exploring potential covariance between dressing shape and material properties. Results: Among the homogeneous dressing shapes, the circular dressing achieved the greatest stress reduction (Delta S = 2.9 %) versus the rectangular control (0.9 %). In the circular form, incorporating a stiffer peripheral symmetric ring around a softer core improved performance (Delta S = 3.2 %) while maintaining substantial lateral displacement (3.35 mm), achieving an optimal combination of stress relief with closure assistance. A fully stiff homogeneous dressing maximized the Delta S (6.5 %) but provided negligible closure support, whereas a fully soft dressing behaved conversely. The sensitivity analysis did not change these quantitative rankings across the studied model variants. Conclusions: Eliminating sharp or small-radius geometric discontinuities and tuning the regional stiffness can markedly attenuate peri-incisional stresses without compromising the contribution of the dressing to the closure work. Circular suNPWT dressings with a peripheral stiffer ring offer a biomechanically superior, manufacturable alternative to conventional rectangular designs, warranting further pre-clinical and clinical evaluations.-
dc.description.sponsorshipThis work was partially supported by the Israeli Ministry of Innovation, Science and Technology: Breakthrough Research Program Grant no. 1001702603, awarded to Professor Amit Gefen in 2023.-
dc.language.isoen-
dc.publisherELSEVIER SCI LTD-
dc.rights2025 The Authors. Published by Elsevier Ltd on behalf of Society of Tissue Viability. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).-
dc.subject.otherDressing design and shape optimization-
dc.subject.otherWound healing biomechanics-
dc.subject.otherComputational finite element modeling and simulations-
dc.subject.otherMechanobiology in wound care-
dc.subject.otherSkin and subdermal tissue stress-
dc.titleBe there or be square: Should we adopt non-rectangular dressing shapes in single-use negative pressure wound therapy?-
dc.typeJournal Contribution-
dc.identifier.issue1-
dc.identifier.volume35-
local.format.pages10-
local.bibliographicCitation.jcatA1-
dc.description.notesGefen, A (corresponding author), Tel Aviv Univ, Fac Engn, Herbert J Berman Chair Vasc Bioengn, Sch Biomed Engn,Biomed Engn, IL-69978 Tel Aviv, Israel.-
dc.description.notesgefen@tauex.tau.ac.il-
local.publisher.place125 London Wall, London, ENGLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr100977-
dc.identifier.doi10.1016/j.jtv.2025.100977-
dc.identifier.pmid41351949-
dc.identifier.isi001636957400001-
local.provider.typewosris-
local.description.affiliation[Barzilay, Ofek; Gefen, Amit] Tel Aviv Univ, Fac Engn, Sch Biomed Engn, Tel Aviv, Israel.-
local.description.affiliation[Gefen, Amit] Univ Ghent, Univ Ctr Nursing & Midwifery, Dept Publ Hlth & Primary Care, Skin Integr Res Grp SKINT, Ghent, Belgium.-
local.description.affiliation[Gefen, Amit] Hasselt Univ, Dept Math & Stat, Fac Sci, Hasselt, Belgium.-
local.description.affiliation[Gefen, Amit] Hasselt Univ, Data Sci Inst, Fac Sci, Hasselt, Belgium.-
local.uhasselt.internationalyes-
item.fulltextWith Fulltext-
item.contributorBarzilay, Ofek-
item.contributorGEFEN, Amit-
item.accessRightsOpen Access-
item.fullcitationBarzilay, Ofek & GEFEN, Amit (2026) Be there or be square: Should we adopt non-rectangular dressing shapes in single-use negative pressure wound therapy?. In: Journal of tissue viability, 35 (1) (Art N° 100977).-
crisitem.journal.issn0965-206X-
crisitem.journal.eissn1876-4746-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
main.pdfPublished version4.56 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.