Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/48819
Title: Experimental and analytical assessment of the sheathing-to-framing connection behavior in timber frame walls with single-sided double-layered sheathing panels A R T I C L E I N F O Keywords: Experiments Analytical Connections in shear walls Timber Ductility Staples Failure modes Eurocode 5 Double-layered sheathing panel Gypsum plasterboard
Authors: BYLOOS, Dries 
VANDOREN, Bram 
Issue Date: 2026
Publisher: Elsevier
Source: Engineering structures, 357 , p. 122512 (Art N° 122512)
Abstract: This study investigates the structural performance of sheathing-to-framing connections in timber frame walls incorporating single-sided double-layered sheathing panels. An experimental program was conducted, involving monotonic push-out shear tests on various materials and fastening combinations, with loading applied both parallel and perpendicular to the timber grain. The study assessed key performance indicators such as shear strength, stiffness, ductility, and failure mechanisms for single-and double-layered sheathing configurations using gypsum-based and wood-based panels. Results demonstrated that adding a second sheathing layer significantly enhances shear capacity and stiffness, typically resulting in an increase by a factor of 1.7-2.9, depending on configuration. However, the effect on ductility was configuration-dependent, with notable increases observed in setups using non-structural inner layers. The failure modes varied by sheathing type: gypsum panels exhibited staple punching and cracking, while wood-based panels showed staple withdrawal. Analytical predictions, derived from adapted Johansen and Blaßmodels, aligned well with experimental shear capacities and expected failure modes in most configurations, particularly for those using non-load-bearing sheathing materials. Comparisons with large-scale wall racking tests validated the small-scale findings, although some discrepancies in stiffness were observed due to possible construction imperfections in the full assemblies. Ultimately, this work addresses a gap in both the current and forthcoming second generation of Eurocode 5, which currently lacks provisions for single-sided, double-layered wall systems.
Keywords: : Experiments;Analytical;Connections in shear walls;Timber;Ductility;Staples;Failure modes;Eurocode 5;Double-layered sheathing panel;Gypsum plasterboard
Document URI: http://hdl.handle.net/1942/48819
ISSN: 0141-0296
e-ISSN: 1873-7323
DOI: 10.1016/j.engstruct.2026.122512
Rights: 2026 Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies
Category: A1
Type: Journal Contribution
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
1-s2.0-S0141029626004256-main.pdf
  Restricted Access
Published version2.87 MBAdobe PDFView/Open    Request a copy
AuthorVersionConnections.pdf
  Until 2026-10-01
Peer-reviewed author version2.31 MBAdobe PDFView/Open    Request a copy
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.