Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/49104Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | COLSON, Dries | - |
| dc.contributor.author | Vaassen, Femke | - |
| dc.contributor.author | Weterings, Jan | - |
| dc.contributor.author | YALVAC, Burak | - |
| dc.contributor.author | Paul, van Haaren | - |
| dc.contributor.author | Verrijssen, An-Sofie | - |
| dc.contributor.author | Berbee, Maaike | - |
| dc.contributor.author | Van Limbergen, Evert J. | - |
| dc.contributor.author | Bellezzo, Murillo | - |
| dc.contributor.author | Verhaegen, Frank | - |
| dc.contributor.author | RENIERS, Brigitte | - |
| dc.date.accessioned | 2026-05-18T12:20:36Z | - |
| dc.date.available | 2026-05-18T12:20:36Z | - |
| dc.date.issued | 2026 | - |
| dc.date.submitted | 2026-05-18T12:18:42Z | - |
| dc.identifier.citation | Physics in Medicine and Biology, 71 (8) (Art N° 085007) | - |
| dc.identifier.uri | http://hdl.handle.net/1942/49104 | - |
| dc.description.abstract | Objective. To investigate the evolution of beam quality in the Papillon+ contact x-ray therapy device and its dosimetric impact, a fast and straightforward beam quality index (QI) measurement method was proposed and validated. Additionally, the dosimetric consequences of tumour intrusion into the applicator tube were examined through Monte Carlo (MC) simulations and, for the first time, direct in-applicator dose measurements. Approach. QI measurements were performed every four weeks from mid-2022. Half-value layer (HVL) and depth-dose profile measurements in a plastic water low energy range phantom were conducted twice, with a two-year interval. Dose distributions for tumour intrusion scenarios (2.5-10 mm) were assessed using MC simulations and Gafchromic film measurements inside the applicator tube. Gross tumour volume (GTV) dose calculations (physical and EQD2) were performed for varying tumour thicknesses, intrusion depths, and diameters. Main results. All methods consistently demonstrated progressive beam hardening over time, with the HVL increasing from 0.77 mm Al to 0.93 mm Al. This spectral shift, attributed to x-ray tube ageing and radiation-induced material changes, was reversibly corrected after service replacement of the flattening filter, restoring the soft spectrum (HVL approximate to 0.69 mm Al). Tumour intrusion produced the strongest dosimetric effect, with surface dose increases up to 2.4-fold at 10 mm intrusion, exceeding MC predictions. GTV D90 decreased with tumour thickness but increased sharply with intrusion depth, whereas tumour diameter and surrounding medium had a negligible impact. Significance. This work highlights the importance of systematic beam quality follow-up in contact x-ray brachytherapy systems. Routine QI monitoring, together with well-defined beam-quality specifications and action limits, enables early detection of deviations, timely maintenance, and sustained compliance of the delivered beam quality in clinical practice. Tumour positioning relative to and protrusion into the applicator remains the dominant factor affecting dose distribution, underscoring the need for precise clinical setup and ongoing device characterisation to ensure clinical accuracy and patient safety. | - |
| dc.description.sponsorship | Acknowledgment We gratefully acknowledge the financial support provided by the Special Research Fund (Bijzonder Onderzoeksfonds, BOF). This research was made possible through the grant BOF19DOC28 awarded to Dries Colson. We further thank Ariane Medical Systems for providing the data and discussion that made it possible to create the MC model. The PRISM-eBT project, with project number 18NRM02, has received funding from the EMPIR programme, co-financed by the Participating States and the European Union’s Horizon 2020 research and innovation programme. The computational resources and services used in this work were provided by the VSC (Flemish Supercomputer Center), funded by the Research Foundation—Flanders (FWO) and the Flemish Government. | - |
| dc.language.iso | en | - |
| dc.publisher | IOP Publishing Ltd | - |
| dc.rights | 2026 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved. | - |
| dc.subject.other | GTV calculation | - |
| dc.subject.other | percentage depth dosem | - |
| dc.subject.other | Monte Carlo modelling | - |
| dc.subject.other | contact x-ray brachytherapy | - |
| dc.subject.other | Papillon treatment | - |
| dc.subject.other | rectal cancer | - |
| dc.title | Assessing dosimetric uncertainties in Papillon plus contact x-ray brachytherapy for rectal cancer: impact of beam quality and tumour geometry | - |
| dc.type | Journal Contribution | - |
| dc.identifier.issue | 8 | - |
| dc.identifier.volume | 71 | - |
| local.format.pages | 20 | - |
| local.bibliographicCitation.jcat | A1 | - |
| dc.description.notes | Reniers, B (corresponding author), Hasselt Univ, Fac Engn Technol, Nucl Technol Ctr NuTeC, Hasselt, Belgium. | - |
| dc.description.notes | brigitte.reniers@uhasselt.be | - |
| local.publisher.place | No.2 The Distillery, Glassfields, Avon Street, Bristol, ENGLAND | - |
| local.type.refereed | Refereed | - |
| local.type.specified | Article | - |
| local.bibliographicCitation.artnr | 085007 | - |
| local.type.programme | H2020 | - |
| local.relation.h2020 | 18NRM02 | - |
| dc.identifier.doi | 10.1088/1361-6560/ae5757 | - |
| dc.identifier.pmid | 41880757 | - |
| dc.identifier.isi | 001751633000001 | - |
| dc.contributor.orcid | Weterings, Jan/0009-0003-1188-5713 | - |
| local.provider.type | wosris | - |
| local.description.affiliation | [Colson, Dries; Yalvac, Burak; Reniers, Brigitte] Hasselt Univ, Fac Engn Technol, Nucl Technol Ctr NuTeC, Hasselt, Belgium. | - |
| local.description.affiliation | [Vaassen, Femke; Berbee, Maaike; Van Limbergen, Evert J.; Bellezzo, Murillo; Verhaegen, Frank] Maastricht Univ, Med Ctr, GROW Res Inst Oncol & Reprod, Dept Radiat Oncol MAASTRO, Maastricht, Netherlands. | - |
| local.description.affiliation | [Weterings, Jan; Paul, van Haaren; Verrijssen, An-Sofie] Catharina Hosp, Dept Radiat Oncol, Eindhoven, Netherlands. | - |
| local.uhasselt.international | yes | - |
| item.contributor | COLSON, Dries | - |
| item.contributor | Vaassen, Femke | - |
| item.contributor | Weterings, Jan | - |
| item.contributor | YALVAC, Burak | - |
| item.contributor | Paul, van Haaren | - |
| item.contributor | Verrijssen, An-Sofie | - |
| item.contributor | Berbee, Maaike | - |
| item.contributor | Van Limbergen, Evert J. | - |
| item.contributor | Bellezzo, Murillo | - |
| item.contributor | Verhaegen, Frank | - |
| item.contributor | RENIERS, Brigitte | - |
| item.fullcitation | COLSON, Dries; Vaassen, Femke; Weterings, Jan; YALVAC, Burak; Paul, van Haaren; Verrijssen, An-Sofie; Berbee, Maaike; Van Limbergen, Evert J.; Bellezzo, Murillo; Verhaegen, Frank & RENIERS, Brigitte (2026) Assessing dosimetric uncertainties in Papillon plus contact x-ray brachytherapy for rectal cancer: impact of beam quality and tumour geometry. In: Physics in Medicine and Biology, 71 (8) (Art N° 085007). | - |
| item.fulltext | With Fulltext | - |
| item.accessRights | Restricted Access | - |
| crisitem.journal.issn | 0031-9155 | - |
| crisitem.journal.eissn | 1361-6560 | - |
| Appears in Collections: | Research publications | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| xx.pdf Restricted Access | Published version | 3.69 MB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.