Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/49684
Title: Validation and implementation of ambulatory obstructive sleep apnea polygraphy screening combined with wearable semi-continuous heart rhythm monitoring in patients with atrial fibrillation: a validation and a pilot study
Authors: DELAET, Anouk 
ONDER, Rana 
Vermunicht, Paulien
KNAEPEN, Lieselotte 
DELESIE, Michiel 
Verbraecken, Johan
Weytjens, Karolien
DENDALE, Paul 
VIJGEN, Johan 
HEIDBUCHEL, Hein 
DESTEGHE, Lien 
Issue Date: 2026
Publisher: FRONTIERS MEDIA SA
Source: Frontiers in cardiovascular medicine, 13 (Art N° 1873057)
Abstract: Background Obstructive sleep apnea (OSA) is a prevalent yet underdiagnosed risk factor in atrial fibrillation (AF) patients and may influence AF burden. Systematic OSA screening and long-term non-invasive heart rhythm monitoring to follow up on AF remain challenging in clinical practice. This study aimed to validate the NOX-T3s polygraphy (PG) device for OSA screening, and to evaluate the feasibility of a structured OSA screening pathway combined with semi-continuous heart rhythm monitoring for mapping AF recurrences and burden.Methods In the NOX-T3s validation study, NOX-T3s performance was evaluated in 30 AF patients undergoing PSG, with simultaneous and consecutive home NOX-T3s recordings. In the NOXFib-AF pilot study, the NOX-T3s was used for ambulatory OSA screening in another 30 AF patients, followed by 31 days of semi-continuous rhythm monitoring (every 9 min) via a smartwatch linked to the FibriCheck algorithm and twice-daily spot-checks via the FibriCheck smartphone application. Presence of AF was indicated as >= 1 AF measurement, with episodes defined as consecutive AF measurements terminated by a sinus rhythm measurement. Patients who screened OSA-positive were referred for PSG. Patient comfort with the devices was assessed via questionnaires.Results NOX-T3s demonstrated good diagnostic performance for detecting moderate-to-severe OSA (AUC 0.83 simultaneous; 0.80 home), with Apnea-Hypopnea Index (AHI) values comparable to PSG (simultaneous recording Delta 0.5 (IQR:-4.2-3.3); p = 0.942; separate-night recordings Delta 1.5 (IQR:-3.7-7.4); p = 0.306). An optimized AHI cut-off of 11.1 events/h improved NOX-T3s accuracy (0.85), with high sensitivity (92.9%) and specificity (75.0%). OSA screening was successful in the NOXFib-AF study in 97.1% of patients, identifying moderate-to-severe OSA in 79.3%. 91.3% underwent PSG, confirming OSA in 61.9%. Semi-continuous smartwatch-based rhythm monitoring was successful in 96.6%, 61.0% +/- 11.5 was high-quality data, and there was high compliance and motivation. AF was detected in 64.3%, and the smartwatch detected 6.7 times more AF episodes compared to spot-check alone. Comfort was high for both NOX-T3s (32 out of 40 (IQR: 29-35) and rhythm monitoring [34 out of 40 (IQR: 29-37)].Conclusions NOX-T3s with an AHI cut-off >= 11.1 events/h is a reliable home screening tool for moderate-to-severe OSA. NOX-T3s-based OSA screening combined with semi-continuous FibriCheck-based rhythm monitoring has proven feasible and acceptable in AF patients.
Notes: Delaet, A (corresponding author), Hasselt Univ, Fac Med & Life Sci, Hasselt, Belgium.; Delaet, A (corresponding author), Jessa Hosp, Dept Cardiol, Hasselt, Belgium.; Delaet, A (corresponding author), Antwerp Univ Hosp, Dept Cardiol, Antwerp, Belgium.
anouk.delaet@uhasselt.be
Keywords: atrial fibrillation;cardiac monitoring;mHealth;obstructive sleep apnea;polygraphy;screening
Document URI: http://hdl.handle.net/1942/49684
ISSN: 2297-055X
e-ISSN: 2297-055X
DOI: 10.3389/fcvm.2026.1873057
ISI #: 001815511400001
Rights: 2026 Delaet, Önder, Vermunicht, Knaepen, Delesie, Verbraecken, Weytjens, Dendale, Vijgen, Heidbuchel and Desteghe. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms
Category: A1
Type: Journal Contribution
Appears in Collections:Research publications