Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/50004
Full metadata record
DC FieldValueLanguage
dc.contributor.authorValgaerts, Laura-
dc.contributor.authorDe Meulemeester, Jolien-
dc.contributor.authorVisser, Margaretha M.-
dc.contributor.authorCharleer, Sara-
dc.contributor.authorFIEUWS, Steffen-
dc.contributor.authorKeymeulen, Bart-
dc.contributor.authorDe Block, Christophe-
dc.contributor.authorMathieu, Chantal-
dc.contributor.authorCasteels, Kristina-
dc.contributor.authorGillard, Pieter-
dc.date.accessioned2026-09-07T11:30:38Z-
dc.date.available2026-09-07T11:30:38Z-
dc.date.issued2026-
dc.date.submitted2026-09-07T11:25:51Z-
dc.identifier.citationDiabetes care, 49 (9) , p. 1637 -1644-
dc.identifier.urihttp://hdl.handle.net/1942/50004-
dc.description.abstractOBJECTIVE To evaluate the association between fear and perceived frequency of hypoglycemia and continuous glucose monitoring (CGM) metrics in adults with type 1 diabetes using diabetes technology over 12 months. RESEARCH DESIGN AND METHODS This retrospective explorative analysis evaluated correlations between hypoglycemia fear, perceived hypoglycemia frequency, and CGM metrics in 1,370 adults with type 1 diabetes using real-time CGM (Comparing Continuous With Flash Glucose Monitoring in Adults With Type 1 Diabetes [ALERTT1] study,n= 254) or hybrid closed-loop (The Impact of Hybrid Closed-Loop Insulin Delivery in Type 1 Diabetes on Glycemic Control and PROMs [INRANGE] studies,n= 1,116) for 12 months. Hypoglycemia fear was assessed with the Hypoglycemia Fear Survey II worry (HFS-worry) and behavior (HFS-behavior) subscales and perceived hypoglycemia frequency with the hypoglycemia subscale of the Diabetes Treatment Satisfaction Questionnaire-status (DTSQs-hypo). Data are reported as mean +/- SD. RESULTS At baseline (before the start of technology), mean age was 41.0 +/- 13.7 years, 55.9% were women, diabetes duration was 21.6 +/- 12.7 years, HbA(1c)was 7.6 +/- 1.0% (59.0 +/- 10.8 mmol/mol), and time in 3.9-10.0 mmol/L was 61.1 +/- 15.5%. Over 12 months, time <3.9/<3.0 mmol/L decreased from 3.4 +/- 3.5%/0.8 +/- 1.4% to 2.3 +/- 2.2%/0.5 +/- 0.7%, while HFS-worry (21.0 +/- 12.9 to 16.8 +/- 12.1) and DTSQs-hypo (3.3 +/- 1.5 to 2.7 +/- 1.4) also decreased. HFS-worry, HFS-behavior, and DTSQs-hypo showed no clear correlations with time in hypoglycemia or other CGM metrics at baseline, at 12 months, or over 12-month change. CONCLUSIONS In adults using diabetes technology over 12 months, fear and perceived frequency of hypoglycemia showed no clear correlations with CGM metrics, suggesting both are influenced by more than glycemic profiles alone.-
dc.language.isoen-
dc.publisherAMER DIABETES ASSOC-
dc.subject.otherHumans-
dc.subject.otherContinuous Glucose Monitoring-
dc.subject.otherFemale-
dc.subject.otherAdult-
dc.subject.otherMale-
dc.subject.otherRetrospective Studies-
dc.subject.otherMiddle Aged-
dc.subject.otherBlood Glucose-
dc.subject.otherBlood Glucose Self-Monitoring-
dc.subject.otherInsulin Infusion Systems-
dc.subject.otherDiabetes Mellitus, Type 1-
dc.subject.otherHypoglycemia-
dc.subject.otherFear-
dc.titleThe Correlation Between Fear and Perceived Frequency of Hypoglycemia and Continuous Glucose Monitoring Metrics in Adults With Type 1 Diabetes Using Diabetes Technology: A 1-Year Analysis-
dc.typeJournal Contribution-
dc.identifier.epage1644-
dc.identifier.issue9-
dc.identifier.spage1637-
dc.identifier.volume49-
local.format.pages8-
local.bibliographicCitation.jcatA1-
dc.description.notesGillard, P (corresponding author), Katholieke Univ Leuven, Univ Hosp Leuven, Dept Endocrinol, Dept Clin & Expt Endocrinol, Leuven, Belgium.-
dc.description.notespieter.gillard@uzleuven.be-
local.publisher.place1701 N BEAUREGARD ST, ALEXANDRIA, VA 22311-1717 USA-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.2337/dc26-0763-
dc.identifier.pmid42406897-
dc.identifier.isi001855424400011-
dc.contributor.orcidDe Meulemeester, Jolien/0000-0002-6007-6715-
local.provider.typewosris-
local.description.affiliation[Valgaerts, Laura; De Meulemeester, Jolien; Visser, Margaretha M.; Charleer, Sara; Mathieu, Chantal; Gillard, Pieter] Katholieke Univ Leuven, Univ Hosp Leuven, Dept Endocrinol, Dept Clin & Expt Endocrinol, Leuven, Belgium.-
local.description.affiliation[Fieuws, Steffen] Katholieke Univ Leuven, Interuniv Inst Biostat & Stat Bioinformat, Leuven, Belgium.-
local.description.affiliation[Fieuws, Steffen] Univ Hasselt, Leuven, Belgium.-
local.description.affiliation[Keymeulen, Bart] Univ Hosp Brussels, Dept Diabetol, Brussels, Belgium.-
local.description.affiliation[De Block, Christophe] Univ Antwerp, Univ Hosp Antwerp, Fac Med & Hlth Sci, Dept Endocrinol Diabetol, Antwerp, Belgium.-
local.description.affiliation[Casteels, Kristina] Katholieke Univ Leuven, Univ Hosp Leuven, Dept Pediat, Dept Dev & Regenerat, Leuven, Belgium.-
local.uhasselt.internationalno-
item.fullcitationValgaerts, Laura; De Meulemeester, Jolien; Visser, Margaretha M.; Charleer, Sara; FIEUWS, Steffen; Keymeulen, Bart; De Block, Christophe; Mathieu, Chantal; Casteels, Kristina & Gillard, Pieter (2026) The Correlation Between Fear and Perceived Frequency of Hypoglycemia and Continuous Glucose Monitoring Metrics in Adults With Type 1 Diabetes Using Diabetes Technology: A 1-Year Analysis. In: Diabetes care, 49 (9) , p. 1637 -1644.-
item.contributorValgaerts, Laura-
item.contributorDe Meulemeester, Jolien-
item.contributorVisser, Margaretha M.-
item.contributorCharleer, Sara-
item.contributorFIEUWS, Steffen-
item.contributorKeymeulen, Bart-
item.contributorDe Block, Christophe-
item.contributorMathieu, Chantal-
item.contributorCasteels, Kristina-
item.contributorGillard, Pieter-
item.fulltextNo Fulltext-
item.accessRightsClosed Access-
crisitem.journal.issn0149-5992-
crisitem.journal.eissn1935-5548-
Appears in Collections:Research publications
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.