Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/907
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCOOREMAN, Peter-
dc.contributor.authorTHOELEN, Ronald-
dc.contributor.authorMANCA, Jean-
dc.contributor.authorVAN DE VEN, Martin-
dc.contributor.authorVERMEEREN, Veronique-
dc.contributor.authorMICHIELS, Luc-
dc.contributor.authorAMELOOT, Marcel-
dc.contributor.authorWAGNER, Patrick-
dc.date.accessioned2006-02-27T13:24:33Z-
dc.date.available2006-02-27T13:24:33Z-
dc.date.issued2005-
dc.identifier.citationBiosensors and Bioelectronics, 20(10). p. 2151-2156-
dc.identifier.issn0956-5663-
dc.identifier.urihttp://hdl.handle.net/1942/907-
dc.description.abstractIn the work reported here, we investigated the interaction between the semiconducting polymer MDMO-PPV and antibodies against the fluorescent dyes FITC and Cy5. The antibodies are adsorbed physically onto thin polymer films on gold electrodes, as seen in AFM images of these films. By tuning the antibody concentration, the contact angle of distilled water with the film can be made to vary between 95° and 50°, showing that different surface densities of antibody can be obtained. That these biosensor films specifically bind their antigenic fluorescent molecules from PBS buffer solution is demonstrated by confocal fluorescence microscopy. Specific antigen-antibody recognition is demonstrated by lack of crosssensitivity between the two antibodies and their antigens. In a biosensor prototype based on differential impedance spectroscopy, these polymer films show a clear response to 1 ppb antigen solution, with a time constant of 2 to 3 minutes.-
dc.format.extent375545 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoen-
dc.publisherELSEVIER ADVANCED TECHNOLOGY-
dc.subject.otherBiosensors-
dc.titleImpedimetric Immunosensors Based on the Conjugated Polymer PPV-
dc.typeJournal Contribution-
dc.identifier.epage2156-
dc.identifier.issue10-
dc.identifier.spage2151-
dc.identifier.volume20-
local.bibliographicCitation.jcatA1-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.bibliographicCitation.oldjcatA1-
dc.identifier.doi10.1016/j.bios.2004.08.029-
dc.identifier.isi000227845700036-
item.fulltextWith Fulltext-
item.fullcitationCOOREMAN, Peter; THOELEN, Ronald; MANCA, Jean; VAN DE VEN, Martin; VERMEEREN, Veronique; MICHIELS, Luc; AMELOOT, Marcel & WAGNER, Patrick (2005) Impedimetric Immunosensors Based on the Conjugated Polymer PPV. In: Biosensors and Bioelectronics, 20(10). p. 2151-2156.-
item.accessRightsOpen Access-
item.validationecoom 2006-
item.contributorCOOREMAN, Peter-
item.contributorTHOELEN, Ronald-
item.contributorMANCA, Jean-
item.contributorVAN DE VEN, Martin-
item.contributorVERMEEREN, Veronique-
item.contributorMICHIELS, Luc-
item.contributorAMELOOT, Marcel-
item.contributorWAGNER, Patrick-
crisitem.journal.issn0956-5663-
crisitem.journal.eissn1873-4235-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
660.Coop - Impedimetric.pdf366.74 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

37
checked on Sep 3, 2020

WEB OF SCIENCETM
Citations

42
checked on May 9, 2024

Page view(s)

82
checked on Sep 7, 2022

Download(s)

216
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.