Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/15846
Title: Implementing heat transfer resistivity as a key element in a nanocrystalline diamond based single nucleotide polymorphism detection array
Authors: BERS, Karolien 
VAN GRINSVEN, Bart 
VANDENRYT, Thijs 
MURIB, Mohammed Sharif 
JANSSENS, Wim 
Geerets, B.
AMELOOT, Marcel 
HAENEN, Ken 
MICHIELS, Luc 
DE CEUNINCK, Ward 
WAGNER, Patrick 
Issue Date: 2013
Publisher: ELSEVIER SCIENCE SA
Source: DIAMOND AND RELATED MATERIALS, 38, p. 45-51
Abstract: In this article, we report on the label-free real-time thermal monitoring of the denaturation of specific DNA fragments and its potential to detect and quantify single nucleotide polymorphisms (SNPs). Probe DNA, consisting of a 36-mer fragment was covalently immobilized on nanocrystalline chemical vapour deposition (CVD) diamond platforms and hybridized with a 29-mer target DNA fragment (full matching and/or with a point mutation). It was observed that the change in heat transfer resistance upon denaturation is dependent on the amount of DNA hybridized to the nanocrystalline diamond (NCD) surface. Furthermore the possibility to distinguish between a full matching sequence and its singularly mutated counterpart, when bound to the same NCD surface, was investigated. NCD surfaces were selectively hybridized with both full matching and mutated DNA fragments at different ratios (3:1, 2:2 and 1:3). A clear bipartite response in heat transfer resistivity was observed upon simultaneous denaturation of these DNA fragments. Denaturation temperature could be used to identify the DNA fragment to which each partial response could be attributed. Moreover, the partial increases in heat transfer resistivity related to the hybridized amount of non-mutated or mutated DNA, respectively. These results imply that heat transfer resistivity is a technique which can be used to (i) quantify DNA fragments of interest, (ii) detect and (iii) quantify SNPs in a mixture of mutated and non-mutated DNA fragments. Moreover, it illustrates the potential of this technique to detect SNPs without the necessity to design complex microarrays. (c) 2013 Elsevier B.V. All rights reserved.
Notes: [Bers, K.; van Grinsven, B.; Vandenryt, T.; Murib, M.; Janssen, W.; Geerets, B.; Haenen, K.; De Ceuninck, W.; Wagner, P.] Hasselt Univ, Inst Mat Res, B-3590 Diepenbeek, Belgium. [Vandenryt, T.] XIOS Univ Coll, Dept Appl Engn, B-3590 Diepenbeek, Belgium. [Janssen, W.; Haenen, K.; De Ceuninck, W.; Wagner, P.] IMOMEC, B-3590 Diepenbeek, Belgium. [Ameloot, M.] Hasselt Univ, Biomed Res Inst, B-3590 Diepenbeek, Belgium. karolien.bers@uhasselt.be
Keywords: CVD diamond; Heat transfer resistance; Mutation analysis; Array;Materials Science, Multidisciplinary
Document URI: http://hdl.handle.net/1942/15846
ISSN: 0925-9635
e-ISSN: 1879-0062
DOI: 10.1016/j.diamond.2013.06.008
ISI #: 000324664700010
Category: A1
Type: Journal Contribution
Validations: ecoom 2014
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
bers 1.pdf
  Restricted Access
Published version1.3 MBAdobe PDFView/Open    Request a copy
Show full item record

SCOPUSTM   
Citations

10
checked on Sep 3, 2020

WEB OF SCIENCETM
Citations

9
checked on Apr 14, 2024

Page view(s)

98
checked on Sep 7, 2022

Download(s)

68
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.