Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/24321
Title: | The Reliability of a Semi-automated Algorithm for Detection of Cortical Interruptions in Finger Joints on High Resolution CT Compared to MicroCT | Authors: | PETERS, Martijn Scharmga, A. van Tubergen, A. Arts, J. Loeffen, D. Weijers, R. van Rietbergen, B. GEUSENS, Piet VAN DEN BERGH, Joop |
Issue Date: | 2017 | Publisher: | SPRINGER | Source: | CALCIFIED TISSUE INTERNATIONAL, 101(2), p. 132-140 | Abstract: | We developed a semi-automated algorithm for the detection of cortical interruptions in finger joints using high-resolution peripheral quantitative computed tomography (HR-pQCT). Here, we tested its reliability compared to microCT (A mu CT) as gold standard. Nineteen joints of 10 female anatomic index fingers were imaged by HR-pQCT and A mu CT (82 and 18 A mu m isotropic voxel sizes, respectively). The algorithm was applied for detection of cortical interruptions of different minimum diameters (range > 0.16 to > 0.50 mm). Reliability was tested at the joint level with intra-class correlation coefficient (ICC) for the number of interruptions and interruption surface, and at the level of a single interruption for matching between HR-pQCT and A mu CT with a fixed interruption diameter (> 0.10 mm) on A mu CT. The positive predictive value (PPV0.10mm) and sensitivity(0.10mm) were evaluated. The mean number of interruptions per joint depended on the diameter cut-off and ranged from 3.4 to 53.5 on HR-pQCT and from 1.8 to 45.1 on A mu CT for interruptions > 0.50 to > 0.16 mm, respectively. Reliability at the joint level was almost perfect (ICC >= 0.81) for both the number and surface of interruptions > 0.16 and > 0.33 mm. As expected, the PPV0.10mm increased with increasing interruption diameter from 84.9 to 100%, for interruptions > 0.16 and > 0.50 mm, respectively. However, the sensitivity(0.10mm) decreased with increasing interruption diameter from 62.4 to 4.7%. This semi-automated algorithm for HR-pQCT in finger joints performed best for the detection of cortical interruptions with a minimum diameter of > 0.16 or > 0.33 mm, showing almost perfect reliability at the joint level and interruptions matched with those on A mu CT. | Notes: | [Peters, M.; Scharmga, A.; van Tubergen, A.; Geusens, P.; van den Bergh, J. P.] Maastricht Univ, Div Rheumatol, Dept Internal Med, Med Ctr, POB 5800, NL-6202 AZ Maastricht, Netherlands. [Peters, M.; Scharmga, A.; van Tubergen, A.; Geusens, P.] Res Sch CAPHRI, Sch Publ Hlth & Primary Care, Maastricht, Netherlands. [Peters, M.; Scharmga, A.; van den Bergh, J. P.] Maastricht Univ, NUTRIM Sch Nutr & Translat Res Metab, Maastricht, Netherlands. [Arts, J.; van Rietbergen, B.] Maastricht Univ, Dept Orthopaed Surg, Med Ctr, Maastricht, Netherlands. [Arts, J.; van Rietbergen, B.] Eindhoven Univ Technol, Fac Biomed Engn, Eindhoven, Netherlands. [Loeffen, D.; Weijers, R.] Maastricht Univ, Dept Radiol, Med Ctr, Maastricht, Netherlands. [Geusens, P.; van den Bergh, J. P.] Hasselt Univ, Fac Med & Life Sci, Hasselt, Belgium. [van den Bergh, J. P.] VieCuri Med Ctr, Dept Internal Med, Venlo, Netherlands. | Keywords: | Cortical interruptions; High resolution peripheral quantitative computed tomography; Micro computed tomography; Finger joints; Rheumatoid arthritis;cortical interruptions; high resolution peripheral quantitative computed tomography; micro computed tomography; finger joints; rheumatoid arthritis | Document URI: | http://hdl.handle.net/1942/24321 | ISSN: | 0171-967X | e-ISSN: | 1432-0827 | DOI: | 10.1007/s00223-017-0264-5 | ISI #: | 000404907500002 | Rights: | © The Author(s) 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. | Category: | A1 | Type: | Journal Contribution | Validations: | ecoom 2018 |
Appears in Collections: | Research publications |
Show full item record
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.