Title: | Automated Winston-Lutz Test for Efficient Quality Control in Stereotactic Radiosurgery | Authors: | Darcis, Michiel Leurs, Gert Geens, Kenny Jankelevitch, Alexandra SWINKELS, Wout CLAESEN, Luc |
Issue Date: | 2017 | Publisher: | IEEE Institute of Electrical and Electronics Engineers | Source: | Li, Qingli; Wang, Lipo; Zhou, Mei; Sun, Li; Qiu, Song; Liu, Hongying (Ed.). Proceedings 2017 10th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics CISP-BMEI 2017, IEEE Institute of Electrical and Electronics Engineers,p. 3B-13-3B-18 | Abstract: | Modern oncology and neurosurgery treatments often use stereotactic radiosurgery. Using linear accelerators and appropriate collimators, treatments of predefined high localized radiation doses can be concentrated in small volumes inside the patient. This can be used to treat tumors in otherwise difficult reachable zones of the patient, such as inside the head. In order to avoid unnecessary damage to surrounding healthy tissue, the treatment volume must be positioned as accurate as possible. The Winston-Lutz test is a standard test that is used in quality control procedures to verify the correct alignment of CT scan images with respect to the isocenter of the radiation equipment. The Winston-Lutz test uses a metal Tungsten ball positioned at the isocenter of the linear accelerator to calibrate the system under various positions of the gantry and various angles of the collimator in the gantry head and patient table. In current procedures, the calibration images that are captured during the test are manually interpreted, measured on workstation screens by the medical personnel. This paper presents new automatic methods to accurately determine the center of the metal ball, based on the image center of gravity as well as the automatic detection of the center of a square radiation field around the ball. The calibration results obtained from the automatic image processing based calculations are consistent and precise with a mean difference of 0.17 mm and a standard deviation of 0.15 mm. | Keywords: | Winston-Lutz test; stereotactic radiosurgery; medical image processing; CT scanning; CBCT-imaging; SRS | Document URI: | http://hdl.handle.net/1942/25087 | ISBN: | 9781538619377 | ISI #: | 000464407100398 | Rights: | IEEE Institute of Electrical and Electronics Engineers | Category: | C1 | Type: | Proceedings Paper |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
P1720 Automated Winston-Lutz Test Calibration and Analysis for Stereotactic Radiosurgery.pdf Restricted Access | Peer-reviewed author version | 396.67 kB | Adobe PDF | View/Open Request a copy |
Automated Winston-Lutz Test for Efficient Quality Control in Stereotactic Radiosurgery - Published Version.pdf Restricted Access | Published version | 1.05 MB | Adobe PDF | View/Open Request a copy |
Page view(s)
102
checked on Jun 29, 2022
Download(s)
88
checked on Jun 29, 2022
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.