Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/26688
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVAN DER STRAATEN, Rob-
dc.contributor.authorTIMMERMANS, Annick-
dc.contributor.authorBRUIJNES, Amber-
dc.contributor.authorVanwanseele, Benedicte-
dc.contributor.authorJonkers, Ilse-
dc.contributor.authorDE BAETS, Liesbet-
dc.date.accessioned2018-08-23T08:29:33Z-
dc.date.available2018-08-23T08:29:33Z-
dc.date.issued2018-
dc.identifier.citationSENSORS, 18(8) (Art N° 2638)-
dc.identifier.issn1424-8220-
dc.identifier.urihttp://hdl.handle.net/1942/26688-
dc.description.abstractThis study assesses the reliability and agreement of trunk and lower limb joints’ 3D kinematics, measured by inertial measurement units, during walking and more demanding movement tasks. For data analysis, tasks were divided in open and closed chain phases. Twenty healthy participants were included. On day one, measurements were conducted by “Operator 1” and “Operator 2” to determine between-operator reliability/agreement. On day two, the measurements were conducted by Operator 1, in order to determine within-session reliability/agreement. Furthermore, between-session reliability/agreement was assessed based on data from Operator 1, captured on day one and two. Within-session reliability/agreement was high, and better than between-session and between-operator results for all tasks. The results for walking were generally better than for other movement tasks, for all joint kinematics, and for both open and closed chain phases. Only for the ab/adduction and flexion/extension angles during forward and sideward lunge, reliability and agreement results were comparable to walking, for both the open and closed chain phases. The fact that lunges show similar reliability results than walking for open and closed chain phases, but require more motor control to perform, indicates that the performance of lunges might be interesting to use in further research aiming to identify kinematic differences between populations.-
dc.description.sponsorshipThis study was funded by the Limburg Clinical Research Program (LCRP) UHasselt-ZOL-Jessa, supported by the foundation Limburg Sterk Merk, province of Limburg, Flemish government, Hasselt University, Ziekenhuis Oost-Limburg and Jessa Hospital. The funding organizations did not have a contribution to the creation of this manuscript.-
dc.language.isoen-
dc.rights© 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/)-
dc.subject.otherinertial sensors; motion analysis; biomechanics; repeatability; functional movement-
dc.titleReliability of 3D Lower Extremity Movement Analysis by Means of Inertial Sensor Technology during Transitional Tasks-
dc.typeJournal Contribution-
dc.identifier.issue8-
dc.identifier.volume18-
local.format.pages15-
local.bibliographicCitation.jcatA1-
dc.description.notesvan der Straaten, R (reprint author), Hasselt Univ, REVAL Rehabil Res Ctr, Agoralaan Bldg A, B-3560 Diepenbeek, Belgium. rob.vanderstraaten@uhasselt.be; annick.timmermans@uhasselt.be; amber.bruijnes@zol.be; benedicte.vanwanseele@kuleuven.be; ilse.jonkers@kuleuven.be; liesbet.debaets@uhasselt.be-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr2638-
local.classdsPublValOverrule/author_version_not_expected-
dc.identifier.doi10.3390/s18082638-
dc.identifier.isi000445712400238-
item.accessRightsOpen Access-
item.fullcitationVAN DER STRAATEN, Rob; TIMMERMANS, Annick; BRUIJNES, Amber; Vanwanseele, Benedicte; Jonkers, Ilse & DE BAETS, Liesbet (2018) Reliability of 3D Lower Extremity Movement Analysis by Means of Inertial Sensor Technology during Transitional Tasks. In: SENSORS, 18(8) (Art N° 2638).-
item.fulltextWith Fulltext-
item.validationecoom 2019-
item.contributorVAN DER STRAATEN, Rob-
item.contributorTIMMERMANS, Annick-
item.contributorBRUIJNES, Amber-
item.contributorVanwanseele, Benedicte-
item.contributorJonkers, Ilse-
item.contributorDE BAETS, Liesbet-
crisitem.journal.eissn1424-8220-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
R. van der Straaten (2018) Reliability of 3D Lower Extremity Movement Analysis.pdfPublished version2.65 MBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

4
checked on Sep 3, 2020

WEB OF SCIENCETM
Citations

8
checked on May 16, 2024

Page view(s)

122
checked on Sep 6, 2022

Download(s)

148
checked on Sep 6, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.